Source author record

V. L. Matushko

V. L. Matushko appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

Response of a proportional counter to $^{37}$Ar and $^{71}$Ge: measured spectra versus Geant4 simulation

The energy deposition spectra of $^{37}$Ar and $^{71}$Ge in a miniature proportional counter are measured and compared in detail to the model response simulated with Geant4. A certain modification of the Geant4 code, making it possible to trace the deexcitation of atomic shells properly, is suggested. Modified Geant4 is able to reproduce a response of particle detectors in detail in the keV energy range. This feature is very important for the laboratory experiments that search for massive sterile neutrinos as well as for dark matter searches that employ direct detection of recoil nuclei. This work demonstrates the reliability of Geant4 simulation at low energies.

preprint2015arXiv

The TOF method for the LSDS-100 spectrometer

The first lead neutron slowing-down spectrometer (LSDS) from a pulsed source in elastic scattering on lead nuclei has been constructed in the laboratory of the atomic nucleus of the Physics Institute of the Russian Academy of Sciences LPI. Currently, there are several operating lead neutron slowing-down spectrometers: LSDS-100 in Russia, RINS in United States, KULS in Japan and others. A relation between an energy of lead slowing-down moderated neutrons E (eV) and the time delay of t (μs) is described by the expression: E(t) = K/(t + t_0)^2, where values of K=170.5 (keV μs^2), t_0 = 0.3 (μs) in the case of the LSDS-100 have been measured in the previous experiment. The energy resolution of LSDS is low (30-45%) and is being determined experimentally, but the aperture ratio luminosity of the neutron flux detector is 10^2-10^4 times greater than in the case of a time of flight method technique. It allows to make experiments with small amount of substance and small cross-sections of its interaction with the slowed moderated neutrons.