Researcher profile

V. Alcayne

V. Alcayne contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2026arXiv

Radiative neutron capture cross section of $^{242}$Pu measured at n_TOF-EAR1 in the unresolved resonance region up to 600 keV

Accurate neutron capture cross sections are essential for the design and operation of fast reactors using MOX fuels. For $^{242}$Pu, the Nuclear Energy Agency (NEA) recommends 8--12% accuracy in the fast energy region (2--500 keV), compared to the current uncertainty of 35%. Moreover, integral experiments and previous measurements suggest the evaluated $^{242}$Pu(n,$γ$) cross section is overestimated, particularly in the JEFF-3.3 library, which shows a 14% overestimation between 1 keV and 1 MeV. Recent measurements from LANSCE reported a 20--30% reduction in the 1--40 keV range relative to evaluations. To solve these discrepancies, the $^{242}$Pu(n,$γ$) cross section was measured from 1 to 600 keV at CERN n_TOF-EAR1 facility using a 95(4) mg $^{242}$Pu target, enriched to 99.959%. Gamma rays from neutron capture were detected with an array of C$_6$D$_6$ scintillators and a novel application of the Pulse Height Weighting Technique was employed. The resulting cross section presents a systematic uncertainty between 8 and 12%, reducing the current uncertainties of 35\% and achieving the accuracy requested by the NEA. Analysis using FITACS produced average resonance parameters, consistent with the analysis of the resolved resonance region. Our data align well with Wisshak and Kaeppeler, and are 10--14\% lower than JEFF-3.3 in the 1--250 keV range, helping to achieve consistency with integral benchmarks. At higher energies, our results are in reasonable agreement with ENDF/B-VIII.1 and JEFF-3.3. In contrast, DANCE results appear to underestimate the cross section by a factor of 2--3 above a few keV.

preprint2025arXiv

New measurement of $^{50}$Cr and $^{53}$Cr (n,$γ$) cross sections at n_TOF: a call for chromium nuclear data revision

$^{50}$Cr and $^{53}$Cr are very relevant in criticality safety benchmarks related to nuclear reactors. The discrepancies of up to 30% between the neutron capture cross section evaluations have an important effect on the $k_{eff}$ and $k_{\infty}$ in criticality benchmarks particularly sensitive to chromium. In this work, the $^{50,53}$Cr(n,$γ$) cross sections are to be determined between 1 and 100 keV with an 8-10% accuracy following the requirements of the NEA High Priority Request List (HPRL) to solve the current discrepancies. We have measured these reactions by the time-of-flight technique at the EAR1 experimental area of the n_TOF facility, using an array of four C$_6$D$_6$ detectors with very low neutron sensitivity. The highly-enriched samples used are significantly thinner than in previous measurements, thus minimizing the multiple-scattering effects. We have produced, and analysed with the R-matrix analysis code SAMMY, capture yields featuring 33 resonances of $^{50}$Cr and 51 of $^{53}$Cr with an accuracy between 5% and 9%, hence fulfilling the requirements made by the NEA. The differential and integral cross sections have been compared to previous data and evaluations. The new measured $^{50,53}$Cr(n,$γ$) cross sections provide a valuable input for upcoming evaluations, which are deemed necessary given that the results presented herein do not support the increase in both cross sections proposed in the recent INDEN evaluation.

preprint2022arXiv

The CERN n TOF NEAR station for astrophysics- and application-related neutron activation measurements

A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized by a neutron beam of very high flux, has been designed with the purpose of performing activation measurements of interest for astrophysics and various applications. The beam is transported from the spallation target to the NEAR station through a hole in the shielding wall of the target, inside which a collimator is inserted. The new area is complemented with a γ-ray spectroscopy laboratory, the GEAR station, equipped with a high efficiency HPGe detector, for the measurement of the activity resulting from irradiation of a sample in the NEAR station. The use of a moderator/filter assembly is envisaged, in order to produce a neutron beam of Maxwellian shape at different thermal energies, necessary for the measurement of Maxwellian Averaged Cross Sections of astrophysical interest. A new fast-cycling activation technique is also being investigated, for measurements of reactions leading to isotopes of very short half life.

preprint2019arXiv

Neutron production induced by $α$-decay with Geant4

Neutron production induced by ($α$,n) reactions is important in various scenarios. One of the most relevant ones is related to underground dark matter experiments, where the neutrons produced by the $α$-decay from radioactive contaminants in the detector materials can generate an irreducible background, limiting the sensitivity of the experiment. A precise estimate of the background due to these neutrons is crucial for the experiments currently taking data and for the design of the next generation detectors. In this work, we prove that Geant4 can be used to calculate neutron yields and energy spectra induced by $α$-decay. These neutrons are produced according to the information compiled in data libraries originally written in the ENDF-6 format. In this article we also review the different databases available, showing the differences and similarities among them. Finally, we compare several Geant4 neutron production yields and spectra with experimental data and other codes.