Source author record

Uwe Scheithauer

Uwe Scheithauer appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
2topics
0close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

AES Analysis of Al Bond Pads in Electrically Insulating Surroundings Utilizing Metal Grid Contacting

Bond pads are the electrical interconnections of a microelectronic device to the outside world. A polyimide layer (PI) on top of a microelectronic device protects the whole device against environmental impacts. The bond pads are accessible though openings in this electrically insulating layer. The oxide layer thickness and contaminations at the Al bond pad surface influence as well the quality of the mechanical and electrical joint between bond pad and bond wire as the durability of this interconnection. If a bond pad surface has to be analyzed with high spatial resolution Auger electron spectroscopy (AES) is the method of choice. AES utilizes an electron beam for excitation, which induces serious sample charging because of the PI layer. Sample charging can be avoided by metal grids, which are common in transmission electron microscopy (TEM) sample preparation. A TEM grid is pressed onto the sample while the bond pad of interest is centered in the square openings of the grid. Exemplarily analyses of bond pads demonstrate the applicability of this approach for AES measurements.

preprint2021arXiv

Depth resolution optimized sputter depth profiling of a polycrystalline Al layer

Depth profiling of thin films by inert gas sputtering is one of the most important applications of Auger electron spectroscopy and X-ray photoelectron spectroscopy. Such an analysis monitors the elemental in-depth composition of the thin film system and controls the quality of the manufacturing process. A challenging task of a sputter depth profile measurement is the determination of the interface contaminations. Interface contaminations are only detectable if the depth profile data were measured with a sufficient depth resolution. Interface contaminations are crucial, because they strongly influence the mechanical and electrical properties of the whole thin film system. The depth resolution of unidirectional sputter depth profiling for polycrystalline samples is limited by the sputter yield differences attributed to grains having different crystalline orientations relative to the incoming ion beam. Therefore depth resolution optimized sputter depth profiling of polycrystalline thin films requires dedicated experimental approaches. If the sample is rotated during ion sputtering the depth profile is recorded with a better depth resolution because the ion impact direction relative to the grains orientation varies. If depth profiling can be performed on a single grain only, the depth resolution is improved, too. These approaches are applied to the depth profiling and interface contamination analysis of a 5000 nm thick polycrystalline Al layer. An O contamination at the interface of the Al to the Si substrate was detected utilizing these high depth resolution depth profiling methods.

preprint2017arXiv

Vacuum Quality Monitoring of Analytical Sputter Depth Profile Equipment by Recontamination Measurements of a Sputtered Ti Surface

Often a surface sensitive analytical technique in combination with sample erosion by inert ion sputtering is used for compositional in-depth analysis of solid state samples. Layer by layer the sample gets eroded and then the composition of the actual surface is estimated. The elemental detection limits can be increased by spending more time for the measurement in each sputter depth of the profile measurement. But during this time a significant sample surface recontamination with the element under investigation via adsorption form the vacuum has to be avoided. Commonly the vacuum quality of an analytical instrument is monitored using the base pressure of the UHV system. This article presents a novel method, which improves this crude approach. The recontamination of a sputtered Ti surface by adsorbed residual gas particles was used to monitor the sputter depth profile specific vacuum condition of an XPS microprobe Quantum 2000 over a 4 years period. This new method is suitable to monitor the condition of every sputter depth profiling instrument.

preprint2015arXiv

Application of the analytical methods REM/EDX, AES and SNMS to a chlorine induced aluminium corrosion

Scanning electron microscopy - SEM - with energy dispersive X-ray detection - EDX -, Auger electron spectroscopy - AES - and sputtered neutral mass spectrometry - SNMS - have been used to characterize a chlorine induced corrosion of an aluminium metallisation. SEM/EDX detects the characteristic X-rays that are emitted from the first few micrometers beneath the specimens surface after inner shell ionisation by the primary electrons. AES detects the alternatively ejected Auger electrons that are generated within the topmost atomic layers of the sample. To obtain elemental concentration depth profiles, the surface layers are removed by ion sputtering. Whereas AES detects the composition of the remaining surface, SNMS measures sputtered fluxes and does not suffer from preferential sputtering. As demonstrated by the example of a chlorine induced aluminium corrosion, these analytical methods are complementary with respect to quantification, chemical information and information depth. Only by simultaneous use measuring artefacts are detectable and able to be excluded from interpretation.

preprint2015arXiv

Examples for the improvements in AES Depth Profiling of Multilayer Thin Film Systems by Application of Factor Analysis Data Evaluation

Factor Analysis has proved to be a powerful tool for the full exploitation of the chemical information included in the peak shapes and peak positions of spectra measured by AES depth profiling. Due to its ability to extract the number of independent chemical components, their spectra and their depth distributions, its information content exceeds the one of the usual peak-to-peak height evaluation of AES depth profile data. Using modern software with a graphically interactive user interface the analyst is put into a position, where he can work with Factor Analysis on a physically intuitive level despite of all the matrix algebra mathematics which it is based upon. The progress brought about by Factor Analysis to AES depth profiles of thin films is demonstrated by the analysis of two thin film systems. The first one is a Pt/Ti metallisation used as bottom electrode for ferroelectric thin films, the second one is multilayer system where a Ti silicide formation of burried Ti/Si bilayers has been induced. Both examples show that Factor Analysis evaluation of AES depth profile data is capable to give access to stoichiometry information and to reveal interfacial layer phases, information which is hardly obtained from the conventional peak-to-peak height data evaluation.

preprint2015arXiv

In-Situ Low-Angle Cross Sectioning: Bevel Slope Flattening due to Self-Alignment Effects

Low-angle cross sections are produced inside an Auger microprobe using the equipped depth profile ion sputter gun. Simply the sample is partly covered by a mask. Utilizing the edge of this mask the sample is sputtered with ions. Due to the shading of the mask a cross section is produced in the sample. The slope of this cross section is considerably shallower than given by the geometrical setup. This is attributed to self-alignment effects, which are due to missing sputter cascades in the transition area between sputtered and shaded sample regions and a chamfering of the mask edge. These self-alignment effects are studied here using a 104.6 nm thick SiO2 layer thermally grown on a Si substrate. In this study on one hand for a fixed ion impact angle of 15.8° as function of the sputter time several in-situ low-angle cross sections were produced. This way slope angles between an ultimate low slope angle of 0.014° and 0.085° were achieved. On the other hand for a fixed sputter time the ion impact angle was varied between 14.8°and 70.8°. For these samples cross section slope angles between 0.031°and 0.32°are observed. These results demonstrate the distinct slope flatting of in-situ cross sectioning.

preprint2015arXiv

Long Time Stability of the Energy Scale Calibration of a Quantum 2000

According to the international standard ISO 15472 the energy scale of an XPS instrument, type Physical Electronics Quantum 2000, was calibrated. It is shown, how the procedures of the ISO 15472 were adapted to the hardware and software design of the Quantum 2000. The long time stability of the energy scale calibration of the XPS instrument was investigated. The instrumented was operated with a satisfying energy scale calibration over a period of 8 years. All the time energy differences between certain peaks could be measured with the chosen precision of the energy scale calibration.

preprint2015arXiv

Reducing the Aspect Ratio of Contact Holes by In-Situ Low-Angle Cross Sectioning

Auger analysis of high-aspect ratio contact holes of integrated microelectronic devices is a challenging analytical task. Due to geometrical shadowing the primary electron beam and the energy analyser have not the required direct line of sight to the analysis area simultaneously. To solve this problem sample preparation is needed to flatten the 3-dimensional geometry. Here the new approach of in-situ low-angle cross sectioning is applied. By this method material gets removed inside the Auger instrument while the sample is sputtered by Ar+ ions at nearly grazing incidence utilizing the edge of a mask, which partly covers the sample. A very shallow bevel with respect to the sample surface is produced. Thus along the bevel contact holes with suitable aspect ratios are available for the Auger analysis.

preprint2013arXiv

Sputter-Induced Cross-Contaminations in Analytical AES and XPS Instrumentation: Utilization of the effect for the In-situ Deposition of Ultrathin Functional Layers

Cross contaminations are observed on sample surfaces by AES and XPS, if multiple samples are mounted on one sample holder and a neighbouring sample was sputter depth profiled. During sputter depth profiling sputtered material is deposited on inner surfaces of the instrument. In a secondary sputter process, which is due to species leaving the primary sputter target with higher kinetic energy, the previously deposited material is transported from the inner surfaces to the other samples mounted on the sample holder. This Reflective Sputtering is utilized to deposit ultra-thin layers on sample surfaces for XPS binding energy referencing purpose and to build up ultra-thin conductive layers to enable AES measurements on insulating samples.