Researcher profile

Tsutomu Nagayoshi

Tsutomu Nagayoshi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
6works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

A spatially resolved study of hard X-ray emission in Kepler's SNR: indications of different regimes of particle acceleration

Synchrotron X-ray emission in young supernova remnants (SNRs) is a powerful diagnostic tool to study the population of high energy electrons accelerated at the shock front and the acceleration process. We performed a spatially resolved spectral analysis of NuSTAR and XMM-Newton observations of the young Kepler's SNR, aiming to study in detail its non-thermal emission in hard X-rays. We selected a set of regions all around the rim of the shell and extracted the corresponding spectra. The spectra were analyzed by adopting a model of synchrotron radiation in the loss-limited regime, to constrain the dependence of the cutoff energy of the synchrotron radiation on the shock velocity. We identify two different regimes of particle acceleration, characterized by different Bohm factors. In the north, where the shock interacts with a dense circumstellar medium (CSM), we found a more efficient acceleration than in the south, where the shock velocity is higher and there are no signs of shock interaction with dense CSM. Our results suggest an enhanced efficiency of the acceleration process in regions where the shock-CSM interaction generates an amplified and turbulent magnetic field. By combining hard X-ray spectra with radio and $γ-$ray observations of Kepler's SNR, we modelled the spectral energy distribution. In the light of our results we propose that the observed $γ-$ray emission is mainly hadronic, and originates in the northern part of the shell.

preprint2022arXiv

Calibration and performance of the readout system based on switched capacitor arrays for the Large-Sized Telescope of the Cherenkov Telescope Array

The Cherenkov Telescope Array (CTA) is the next-generation ground-based very-high-energy gamma-ray observatory. The Large-Sized Telescope (LST) of CTA is designed to detect gamma rays between 20 GeV and a few TeV with a 23-meter diameter mirror. We have developed the focal plane camera of the first LST, which has 1855 photomultiplier tubes (PMTs) and the readout system which samples a PMT waveform at GHz with switched capacitor arrays, Domino Ring Sampler ver4 (DRS4). To measure the precise pulse charge and arrival time of Cherenkov signals, we developed a method to calibrate the output voltage of DRS4 and the sampling time interval, as well as an analysis method to correct the spike noise of DRS4. Since the first LST was inaugurated in 2018, we have performed the commissioning tests and calibrated the camera. We characterised the camera in terms of the charge pedestal under various conditions of the night sky background, the charge resolution of each pixel, the charge uniformity of the whole camera, and the time resolutions with a test pulse and calibration laser.

preprint2020arXiv

Detection of the hard X-ray non-thermal emission from Kepler's supernova remnant

We report the first robust detection of the hard X-ray emission in the 15--30\,keV band from Kepler's supernova remnant with the silicon PIN-type semiconductor detector of the hard X-ray detector (HXD-PIN) onboard Suzaku. The detection significance is 7.17 $σ$ for the emission from Kepler's entire X-ray emitting region. The energy spectrum is found to be well reproduced by a single power-law function with a photon index of $3.13^{+1.85+0.69}_{-1.52-0.36}$, where the first and second errors represent 90\%-statistical and systematic errors, respectively. The X-ray flux is determined to be 2.75$_{-0.77-0.82}^{+0.78+0.81}\times10^{-12}$\,erg\,s$^{-1}$\,cm$^{-2}$ in the 15--30\,keV band. The wider-band X-ray spectrum in the 3--30\,keV band, where the soft X-ray Suzaku/XIS spectrum is combined, shows that the non-thermal component does not have a significant X-ray roll-off structure. We find that the broad-band energy spectrum from the radio band, X-ray data of this work, and TeV upper limits can be reproduced with the one-zone leptonic model with a roll-off energy of $ν_{\mathrm{roll}}=1.0\times10^{17}$\,Hz and magnetic field strength of $B>40\,\mathrm{μG}$. Application of the diagnostic method using indices in the soft and hard X-ray band to the data indicates that the maximum energy of the accelerated electrons in Kepler's SNR is limited by the age of the remnant. The indication is consistent with the results of the one-zone leptonic modeling.

preprint2011arXiv

Observation of Diffuse Cosmic and Atmospheric Gamma Rays at Balloon Altitudes with an Electron-tracking Compton Camera

We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as the first step toward a future all-sky survey with a high sensitivity. SMILE-I employed an electron-tracking Compton camera comprised of a gaseous electron tracker as a Compton-scattering target and a scintillation camera as an absorber. The balloon carrying the SMILE-I detector was launched from the Sanriku Balloon Center of the Institute of Space and Astronomical Science/Japan Space Exploration Agency on September 1, 2006, and the flight lasted for 6.8 hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the level flight, we successfully detected 420 downward gamma rays between 100 keV and 1 MeV at zenith angles below 60 degrees. To obtain the flux of diffuse cosmic gamma rays, we first simulated their scattering in the atmosphere using Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm-2, we found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV, respectively, were scattered in the atmosphere prior to reaching the detector. Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation model, we estimated that the detected events consisted of diffuse cosmic and atmospheric gamma rays (79%), secondary photons produced in the instrument through the interaction between cosmic rays and materials surrounding the detector (19%), and other particles (2%). The obtained growth curve was comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric gamma rays were consistent with the results of previous experiments. The expected detection sensitivity of a future SMILE experiment measuring gamma rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was found to be ten times better than that of other experiments at around 1 MeV.

preprint2003arXiv

Detecting the WIMP-wind via spin-dependent interactions

Revealing the nature of dark matter is one of the most interesting tasks in astrophysics. Measuring the distribution of recoil angles is said to be one of the most reliable methods to detect a positive signature of dark matter. We focused on measurements via spin-dependent interactions, and studied the feasibility with carbon tetrafluoride($\rm CF_4$) gas, while taking into account the performance of an existing three-dimensional tracking detector. We consequently found that it is highly possible to detect a positive signature of dark matter via spin-dependent interactions.

preprint2003arXiv

Performance of a micro-TPC for a time-resolved neutron PSD

We report on the performance of a micro-TPC with a micro pixel chamber($μ$-PIC) readout for a time-resolved neutron position-sensitive detector(PSD). Three-dimensional tracks and the Bragg curves of protons with energies of around 1 MeV were clearly detected by the micro-TPC. More than 95% of gamma-rays of 511 keV were found to be discriminated by simple analysis. Simulation studies showed that the total track length of proton and triton emitted from the $\rm {}^{3}He$(n,p(573 keV))$\rm {}^{3}H(191 keV)$ reaction is about 1.2 cm, and that both particles have large energy losses ($\rm > 200 keV/cm$) in 1 atm Ar+$\rm C_{2}H_{6}(10%)$+${}^{3}$He($< 1%$). These values suit the current performance of the micro-TPC, and we conclude that a time-resolved neutron PSD with spatial resolution of sub-millimeters shall be developed as an application of the micro-TPC.