Source author record

Trevor M. Oxholm

Trevor M. Oxholm appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

A Beginner's Guide to Line Intensity Mapping Power Spectra

Line intensity mapping (LIM) is an emerging technique in measuring galaxy evolution and the large-scale structure of the universe. LIM surveys measure the cumulative emission from all galaxies emitting a given line at a particular redshift, which trace the distribution of dark matter throughout the universe. In this proceeding, we provide an introduction to LIM modeling, focusing on power spectrum calculation. Beyond these calculations, we describe how these power spectra may be used to constrain properties of galaxy evolution and large-scale structure cosmology. Throughout, we use the anticipated EXCLAIM signal of ionized carbon ([CII]) at redshift $z=3$ as a case study. Our goal is to provide a starting point to non-experts, e.g. upper-level undergraduate and graduate students familiar with the basics of cosmology, with the tools necessary to understand the literature and generate LIM power spectrum models themselves, while also describing a wide array of literature for continued studies.

preprint2022arXiv

Developing a New Generation of Integrated Micro-Spec Far Infrared Spectrometers for the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The current state of far-infrared astronomy drives the need to develop compact, sensitive spectrometers for future space and ground-based instruments. Here we present details of the $\rm μ$-Spec spectrometers currently in development for the far-infrared balloon mission EXCLAIM. The spectrometers are designed to cover the $\rm 555 - 714\ μ$m range with a resolution of $\rm R\ =\ λ/ Δλ =\ 512$ at the $\rm 638\ μ$m band center. The spectrometer design incorporates a Rowland grating spectrometer implemented in a parallel plate waveguide on a low-loss single-crystal Si chip, employing Nb microstrip planar transmission lines and thin-film Al kinetic inductance detectors (KIDs). The EXCLAIM $\rm μ$-Spec design is an advancement upon a successful $\rm R = 64\ μ$-Spec prototype, and can be considered a sub-mm superconducting photonic integrated circuit (PIC) that combines spectral dispersion and detection. The design operates in a single $M{=}2$ grating order, allowing one spectrometer to cover the full EXCLAIM band without requiring a multi-order focal plane. The EXCLAIM instrument will fly six spectrometers, which are fabricated on a single 150 mm diameter Si wafer. Fabrication involves a flip-wafer-bonding process with patterning of the superconducting layers on both sides of the Si dielectric. The spectrometers are designed to operate at 100 mK, and will include 355 Al KID detectors targeting a goal of NEP ${\sim}8\times10^{-19}$ $\rm W/\sqrt{Hz}$. We summarize the design, fabrication, and ongoing development of these $\rm μ$-Spec spectrometers for EXCLAIM.

preprint2022arXiv

Operational Optimization to Maximize Dynamic Range in EXCLAIM Microwave Kinetic Inductance Detectors

Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory environments. In addition, the detectors have a rich design space with many optimizable parameters, allowing highly sensitive measurements over a wide dynamic range. For these reasons, MKIDs were chosen for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM), a balloon-borne telescope targeting nearly background-limited performance in a high-altitude atmospheric environment from 420-540 GHz. We describe MKID optimization in the specific context of EXCLAIM and provide general results that apply to broader applications. Extending the established approach of tone frequency tracking, we show that readout power optimization enables significant, further improvement in dynamic range.

preprint2021arXiv

μ-Spec Spectrometers for the EXCLAIM Instrument

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lines across redshifts from 0 to 3.5, using an intensity mapping approach. EXCLAIM will broaden our understanding of these elemental and molecular gases and the role they play in star formation processes across cosmic time scales. The focal plane of EXCLAIM's cryogenic telescope features six μ-Spec spectrometers. μ-Spec is a compact, integrated grating-analog spectrometer, which uses meandered superconducting niobium microstrip transmission lines on a single-crystal silicon dielectric to synthesize the grating. It features superconducting aluminum microwave kinetic inductance detectors (MKIDs), also in a microstrip architecture. The spectrometers for EXCLAIM couple to the telescope optics via a hybrid planar antenna coupled to a silicon lenslet. The spectrometers operate from 420 to 540 GHz with a resolving power R=λ/Δλ=512 and employ an array of 355 MKIDs on each spectrometer. The spectrometer design targets a noise equivalent power (NEP) of 2x10-18W/\sqrt{Hz} (defined at the input to the main lobe of the spectrometer lenslet beam, within a 9-degree half width), enabled by the cryogenic telescope environment, the sensitive MKID detectors, and the low dielectric loss of single-crystal silicon. We report on these spectrometers under development for EXCLAIM, providing an overview of the spectrometer and component designs, the spectrometer fabrication process, fabrication developments since previous prototype demonstrations, and the current status of their development for the EXCLAIM mission.

preprint2016arXiv

Comparison of spin-orbit torques and spin pumping across NiFe/Pt and NiFe/Cu/Pt interfaces

We experimentally investigate spin-orbit torques and spin pumping in NiFe/Pt bilayers with direct and interrupted interfaces. The damping-like and field-like torques are simultaneously measured with spin-torque ferromagnetic resonance tuned by a dc bias current, whereas spin pumping is measured electrically through the inverse spin Hall effect using a microwave cavity. Insertion of an atomically thin Cu dusting layer at the interface reduces the damping-like torque, field-like torque, and spin pumping by nearly the same factor of ~1.4. This finding confirms that the observed spin-orbit torques predominantly arise from diffusive transport of spin current generated by the spin Hall effect. We also find that spin-current scattering at the NiFe/Pt interface contributes to additional enhancement in magnetization damping that is distinct from spin pumping.

preprint2014arXiv

Quantification of the spin-Hall anti-damping torque with a resonance spectrometer

We present a simple technique using a cavity-based resonance spectrometer to quantify the anti-damping torque due to the spin Hall effect. Modification of ferromagnetic resonance is observed as a function of small DC current in sub-mm-wide strips of bilayers, consisting of magnetically soft FeGaB and strong spin-Hall metal Ta. From the detected current-induced linewidth change, we obtain an effective spin Hall angle of 0.08-0.09 independent of the magnetic layer thickness. Our results demonstrate that a sensitive resonance spectrometer can be a general tool to investigate spin Hall effects in various material systems, even those with vanishingly low conductivity and magnetoresistance.