Source author record

Travis Prochaska

Travis Prochaska appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Medium-band observation of the neutrino emitting blazar, TXS 0506+056

TXS 0506+056 is a blazar that has been recently identified as the counterpart of the neutrino event IceCube-170922A. Understanding blazar type of TXS 0506+056 is important to constrain the neutrino emission mechanism, but the blazar nature of TXS 0506+056 is still uncertain. As an attempt to understand the nature of TXS 0506+056, we report the medium-band observation results of TXS 0506+056, covering the wavelength range of 0.575 to 1.025 $μ$m. The use of the medium-band filters allow us to examine if there were any significant changes in its spectral shapes over the course of one month and give a better constraint on the peak frequency of synchrotron radiation with quasi-simultaneous datasets. The peak frequency is found to be $10^{14.28}$ Hz, and our analysis shows that TXS 0506+056 is not an outlier from the blazar sequence. As a way to determine the blazar type, we also analyzed if TXS 0506+056 is bluer-when-brighter (BL Lac type and some flat spectrum radio quasars, FSRQs) or redder-when-brighter (found only in some FSRQs). Even though we detect no significant variability in the spectral shape larger than observational error during our medium-band observation period, the comparison with a dataset taken at 2012 shows a possible redder-when-brighter behavior of FSRQs. Our results demonstrate that medium-band observations with small to moderate-sized telescopes can be an effective way to trace the spectral evolution of transients such as TXS 0506+056.

preprint2014arXiv

Characterization of the Reflectivity of Various Black Materials

We present total and specular reflectance measurements of various materials that are commonly (and uncommonly) used to provide baffling and/or to minimize the effect of stray light in optical systems. More specifically, we investigate the advantage of using certain black surfaces and their role in suppressing stray light on detectors in optical systems. We measure the total reflectance of the samples over a broad wavelength range (250 < lambda < 2500 nm) that is of interest to astronomical instruments in the ultraviolet, visible, and near-infrared regimes. Additionally, we use a helium-neon laser to measure the specular reflectance of the samples at various angles. Finally, we compare these two measurements and derive the specular fraction for each sample.

preprint2014arXiv

Mass production of volume phase holographic gratings for the VIRUS spectrograph array

The Visible Integral-field Replicable Unit Spectrograph (VIRUS) is a baseline array of 150 copies of a simple, fiber-fed integral field spectrograph that will be deployed on the Hobby-Eberly Telescope (HET). VIRUS is the first optical astronomical instrument to be replicated on an industrial scale, and represents a relatively inexpensive solution for carrying out large-area spectroscopic surveys, such as the HET Dark Energy Experiment (HETDEX). Each spectrograph contains a volume phase holographic (VPH) grating with a 138 mm diameter clear aperture as its dispersing element. The instrument utilizes the grating in first-order for 350-550 nm. Including witness samples, a suite of 170 VPH gratings has been mass produced for VIRUS. Here, we present the design of the VIRUS VPH gratings and a discussion of their mass production. We additionally present the design and functionality of a custom apparatus that has been used to rapidly test the first-order diffraction efficiency of the gratings for various discrete wavelengths within the VIRUS spectral range. This device has been used to perform both in-situ tests to monitor the effects of adjustments to the production prescription as well as to carry out the final acceptance tests of the gratings' diffraction efficiency. Finally, we present the as-built performance results for the entire suite of VPH gratings.

preprint2013arXiv

DECal: A Spectrophotometric Calibration System For DECam

DECal is a new calibration system for the CTIO 4 m Blanco telescope. It is currently being installed as part of the Dark Energy Survey and will provide both broadband flat fields and narrowband (about 1 nm bandwidth) spectrophotometric calibration for the new Dark Energy Camera (DECam). Both of these systems share a new Lambertian flat field screen. The broadband flat field system uses LEDs to illuminate each photometric filter. The spectrophotometric calibration system consists of a monochromator-based tunable light source that is projected onto the flat field screen using a custom line-to-spot fiber bundle and an engineered diffuser. Several calibrated photodiodes positioned along the beam monitor the telescope throughput as a function of wavelength. This system will measure the wavelength-dependent instrumental response function of the total telescope+instrument system in the range 300 < lambda < 1100nm. The spectrophotometric calibration will be performed regularly (roughly once per month) to determine the spectral response of the DECam system and to monitor changes in instrumental throughput during the five year Dark Energy Survey project.