Source author record

Tomasz M. Rutkowski

Tomasz M. Rutkowski appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

25works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

25 published item(s)

preprint2016arXiv

Airborne Ultrasonic Tactile Display BCI

This chapter presents results of our project, which studied whether contactless and airborne ultrasonic tactile display (AUTD) stimuli delivered to a user's palms could serve as a platform for a brain computer interface (BCI) paradigm. We used six palm positions to evoke combined somatosensory brain responses to implement a novel contactless tactile BCI. This achievement was awarded the top prize in the Annual BCI Research Award 2014 competition. This chapter also presents a comparison with a classical attached vibrotactile transducer-based BCI paradigm. Experiment results from subjects performing online experiments validate the novel BCI paradigm.

preprint2016arXiv

Visual Motion Onset Brain-computer Interface

The paper presents a study of two novel visual motion onset stimulus-based brain-computer interfaces (vmoBCI). Two settings are compared with afferent and efferent to a computer screen center motion patterns. Online vmoBCI experiments are conducted in an oddball event-related potential (ERP) paradigm allowing for "aha-responses" decoding in EEG brainwaves. A subsequent stepwise linear discriminant analysis classification (swLDA) classification accuracy comparison is discussed based on two inter-stimulus-interval (ISI) settings of 700 and 150 ms in two online vmoBCI applications with six and eight command settings. A research hypothesis of classification accuracy non-significant differences with various ISIs is confirmed based on the two settings of 700 ms and 150 ms, as well as with various numbers of ERP response averaging scenarios. The efferent in respect to display center visual motion patterns allowed for a faster interfacing and thus they are recommended as more suitable for the no-eye-movements requiring visual BCIs.

preprint2015arXiv

Airborne Ultrasonic Tactile Display Brain-computer Interface -- A Small Robotic Arm Online Control Study

We report on an extended robot control application of a contact-less and airborne ultrasonic tactile display (AUTD) stimulus-based brain-computer interface (BCI) paradigm, which received last year The Annual BCI Research Award 2014. In the award winning human communication augmentation paradigm the six palm positions are used to evoke somatosensory brain responses, in order to define a novel contactless tactile BCI. An example application of a small robot management is also presented in which the users control a small robot online.

preprint2015arXiv

Chromatic and High-frequency cVEP-based BCI Paradigm

We present results of an approach to a code-modulated visual evoked potential (cVEP) based brain-computer interface (BCI) paradigm using four high-frequency flashing stimuli. To generate higher frequency stimulation compared to the state-of-the-art cVEP-based BCIs, we propose to use the light-emitting diodes (LEDs) driven from a small micro-controller board hardware generator designed by our team. The high-frequency and green-blue chromatic flashing stimuli are used in the study in order to minimize a danger of a photosensitive epilepsy (PSE). We compare the the green-blue chromatic cVEP-based BCI accuracies with the conventional white-black flicker based interface.

preprint2015arXiv

Head-related Impulse Response Cues for Spatial Auditory Brain-computer Interface

This study provides a comprehensive test of a head-related impulse response (HRIR) cues for a spatial auditory brain-computer interface (saBCI) speller paradigm. We present a comparison with the conventional virtual sound headphone-based spatial auditory modality. We propose and optimize the three types of sound spatialization settings using a variable elevation in order to evaluate the HRIR efficacy for the saBCI. Three experienced and seven naive BCI users participated in the three experimental setups based on ten presented Japanese syllables. The obtained EEG auditory evoked potentials (AEP) resulted with encouragingly good and stable P300 responses in online BCI experiments. Our case study indicated that users could perceive elevation in the saBCI experiments generated using the HRIR measured from a general head model. The saBCI accuracy and information transfer rate (ITR) scores have been improved comparing to the classical horizontal plane-based virtual spatial sound reproduction modality, as far as the healthy users in the current pilot study are concerned.

preprint2015arXiv

Inter-stimulus Interval Study for the Tactile Point-pressure Brain-computer Interface

The paper presents a study of an inter-stimulus interval (ISI) influence on a tactile point-pressure stimulus-based brain-computer interface's (tpBCI) classification accuracy. A novel tactile pressure generating tpBCI stimulator is also discussed, which is based on a three-by-three pins' matrix prototype. The six pin-linear patterns are presented to the user's palm during the online tpBCI experiments in an oddball style paradigm allowing for "the aha-responses" elucidation, within the event related potential (ERP). A subsequent classification accuracies' comparison is discussed based on two ISI settings in an online tpBCI application. A research hypothesis of classification accuracies' non-significant differences with various ISIs is confirmed based on the two settings of 120 ms and 300 ms, as well as with various numbers of ERP response averaging scenarios.

preprint2015arXiv

Spatial Auditory Brain-computer Interface using Head Related Impulse Response

This study reports on a head related impulse response (HRIR) application to an auditory spatial brain-computer interface (BCI) speller paradigm. Six experienced and five BCI-naive users participated in an experimental spelling set up based on five Japanese vowels. Obtained auditory evoked potentials resulted with encouragingly good and stable P300-responses in online BCI experiments. Our case study indicated that the headphone reproduced auditory (HRIR- based) spatial sound paradigm could be a viable alternative to the established multi-loudspeaker surround sound BCI-speller applications, as far as healthy pilot study users are concerned.

preprint2015arXiv

Student Teaching and Research Laboratory Focusing on Brain-computer Interface Paradigms - A Creative Environment for Computer Science Students -

This paper presents an applied concept of a brain-computer interface (BCI) student research laboratory (BCI-LAB) at the Life Science Center of TARA, University of Tsukuba, Japan. Several successful case studies of the student projects are reviewed together with the BCI Research Award 2014 winner case. The BCI-LAB design and project-based teaching philosophy is also explained. Future teaching and research directions summarize the review.

preprint2015arXiv

Two-step Input Spatial Auditory BCI for Japanese Kana Characters

We present an auditory stimulus optimization and a pilot study of a two-step input speller application combined with a spatial auditory brain-computer interface (saBCI) for paralyzed users. The application has been developed for 45, out of 48 defining the full set, Japanese kana characters in a two-step input procedure setting for an easy-to-use BCI-speller interface. The user first selects the representative letter of a subset, defining the second step. In the second step, the final choice is made. At each interfacing step, the choices are classified based on the P300 event related potential (ERP) responses captured in the EEG, as in the classic oddball paradigm. The BCI online experiment and EEG responses classification results of the pilot study confirm the effectiveness of the proposed spelling method.

preprint2014arXiv

Airborne Ultrasonic Tactile Display Brain-computer Interface Paradigm

We study the extent to which contact-less and airborne ultrasonic tactile display (AUTD) stimuli delivered to the palms of a user can serve as a platform for a brain computer interface (BCI) paradigm. Six palm positions are used to evoke combined somatosensory brain responses, in order to define a novel contact-less tactile BCI. A comparison is made with classical attached vibrotactile transducers. Experiment results of subjects performing online experiments validate the novel BCI paradigm.

preprint2014arXiv

Head-related Impulse Response-based Spatial Auditory Brain-computer Interface

This study provides a comprehensive test of the head-related impulse response (HRIR) to an auditory spatial speller brain-computer interface (BCI) paradigm, including a comparison with a conventional virtual headphone-based spatial auditory modality. Five BCI-naive users participated in an experiment based on five Japanese vowels. The auditory evoked potentials obtained produced encouragingly good and stable P300-responses in online BCI experiments. Our case study indicates that the auditory HRIR spatial sound paradigm reproduced with headphones could be a viable alternative to established multi-loudspeaker surround sound BCI-speller applications.

preprint2014arXiv

Spatial Tactile Brain-Computer Interface Paradigm Applying Vibration Stimuli to Large Areas of User's Back

We aim at an augmentation of communication abilities of amyotrophic lateral sclerosis (ALS) patients by creating a brain-computer interface (BCI) which can control a computer or other device by using only brain activity. As a method, we use a stimulus-driven BCI based on vibration stimuli delivered via a gaming pad to the user's back. We identify P300 responses from brain activity data in response to the vibration stimuli. The user's intentions are classified according to the P300 responses recorded in the EEG. From the results of the psychophysical and online BCI experiments, we are able to classify the P300 responses very accurately, which proves the effectiveness of the proposed method.

preprint2013arXiv

Auditory Brain-Computer Interface Paradigm with Head Related Impulse Response-based Spatial Cues

The aim of this study is to provide a comprehensive test of head related impulse response (HRIR) for an auditory spatial speller brain-computer interface (BCI) paradigm. The study is conducted with six users in an experimental set up based on five Japanese hiragana vowels. Auditory evoked potentials resulted with encouragingly good and stable "aha-" or P300-responses in real-world online BCI experiments. Our case study indicated that the auditory HRIR spatial sound reproduction paradigm could be a viable alternative to the established multi-loudspeaker surround sound BCI-speller applications, as far as healthy pilot study users are concerned.

preprint2013arXiv

Beyond visual P300 based brain-computer interfacing paradigms

The paper reviews and summarizes recent developments in spatial auditory and tactile brain-computer interfacing neurotechology applications. It serves as the latest developments summary in "non-visual" brain-computer interfacing solutions presented in a tutorial delivered by the author at the IICST 2013 workshop. The novel concepts of unimodal auditory or tactile, as well as a bimodal combined paradigms are described and supported with recent research results from our BCI-lab research group at Life Science Center, University of Tsukuba, Japan. The newly developed experimental paradigms fit perfectly to needs of paralyzed or hearing impaired users, in case of tactile stimulus, as well as for able users who cannot utilize vision in computer or machine interaction (driving or operation of machinery required not disturbed eyesight). We present and review the EEG event related potential responses useful for brain computer interfacing applications beyond state-of-the-art visual paradigms. In conclusion the recent results are discussed and suggestions for further applications are drawn.

preprint2013arXiv

EEG Signal Processing and Classification for the Novel Tactile-Force Brain-Computer Interface Paradigm

The presented study explores the extent to which tactile-force stimulus delivered to a hand holding a joystick can serve as a platform for a brain computer interface (BCI). The four pressure directions are used to evoke tactile brain potential responses, thus defining a tactile-force brain computer interface (tfBCI). We present brain signal processing and classification procedures leading to successful interfacing results. Experimental results with seven subjects performing online BCI experiments provide a validation of the hand location tfBCI paradigm, while the feasibility of the concept is illuminated through remarkable information-transfer rates.

preprint2013arXiv

Multi-command Chest Tactile Brain Computer Interface for Small Vehicle Robot Navigation

The presented study explores the extent to which tactile stimuli delivered to five chest positions of a healthy user can serve as a platform for a brain computer interface (BCI) that could be used in an interactive application such as robotic vehicle operation. The five chest locations are used to evoke tactile brain potential responses, thus defining a tactile brain computer interface (tBCI). Experimental results with five subjects performing online tBCI provide a validation of the chest location tBCI paradigm, while the feasibility of the concept is illuminated through information-transfer rates. Additionally an offline classification improvement with a linear SVM classifier is presented through the case study.

preprint2013arXiv

Multi-command Tactile Brain Computer Interface: A Feasibility Study

The study presented explores the extent to which tactile stimuli delivered to the ten digits of a BCI-naive subject can serve as a platform for a brain computer interface (BCI) that could be used in an interactive application such as robotic vehicle operation. The ten fingertips are used to evoke somatosensory brain responses, thus defining a tactile brain computer interface (tBCI). Experimental results on subjects performing online (real-time) tBCI, using stimuli with a moderately fast inter-stimulus-interval (ISI), provide a validation of the tBCI prototype, while the feasibility of the concept is illuminated through information-transfer rates obtained through the case study.

preprint2013arXiv

Multicommand Tactile Brain Computer Interface based on Fingertips or Head Stimulation

The paper presents results from a computational neuroscience study conducted to test vibrotactile stimuli delivered to subject fingertips and head areas in order to evoke the somatosensory brain responses utilized in a haptic brain computer interface (hBCI) paradigm. We present the preliminary and very encouraging results, with subjects conducting online hBCI interfacing experiments, ranging from 40% to 90% with a very fast inter-stimulus-interval (ISI) of 250ms. The presented results confirm our hypothesis that the hBCI paradigm concept is valid and it allows for rapid stimuli presentation in order to achieve a satisfactory information-transfer-rate of the novel BCI.

preprint2013arXiv

Novel Virtual Moving Sound-based Spatial Auditory Brain-Computer Interface Paradigm

This paper reports on a study in which a novel virtual moving sound-based spatial auditory brain-computer interface (BCI) paradigm is developed. Classic auditory BCIs rely on spatially static stimuli, which are often boring and difficult to perceive when subjects have non-uniform spatial hearing perception characteristics. The concept of moving sound proposed and tested in the paper allows for the creation of a P300 oddball paradigm of necessary target and non-target auditory stimuli, which are more interesting and easier to distinguish. We present a report of our study of seven healthy subjects, which proves the concept of moving sound stimuli usability for a novel BCI. We compare online BCI classification results in static and moving sound paradigms yielding similar accuracy results. The subject preference reports suggest that the proposed moving sound protocol is more comfortable and easier to discriminate with the online BCI.

preprint2012arXiv

Auditory Steady-State Response Stimuli based BCI Application - The Optimization of the Stimuli Types and Lengths

We propose a method for an improvement of auditory BCI (aBCI) paradigm based on a combination of ASSR stimuli optimization by choosing the subjects' best responses to AM-, flutter-, AM/FM and click-envelope modulated sounds. As the ASSR response features we propose pairwise phase-locking-values calculated from the EEG and next classified using binary classifier to detect attended and ignored stimuli. We also report on a possibility to use the stimuli as short as half a second, which is a step forward in ASSR based aBCI. The presented results are helpful for optimization of the aBCI stimuli for each subject.

preprint2012arXiv

Haptic BCI Paradigm based on Somatosensory Evoked Potential

A new concept and an online prototype of haptic BCI paradigm are presented. Our main goal is to develop a new, alternative and low cost paradigm, with open-source hardware and software components. We also report results obtained with the novel dry EEG electrodes based signal acquisition system by g.tec, which further improves experimental comfort. We address the following points: a novel application of the BCI; a new methodological approach used compared to earlier projects; a new benefit for potential users of a BCI; the approach working online/in real-time; development of a novel stimuli delivery hardware and software. The results with five healthy subjects and discussion of future developments conclude this submission.

preprint2012arXiv

Psychophysical Responses Comparison in Spatial Visual, Audiovisual, and Auditory BCI-Spelling Paradigms

The paper presents a pilot study conducted with spatial visual, audiovisual and auditory brain-computer-interface (BCI) based speller paradigms. The psychophysical experiments are conducted with healthy subjects in order to evaluate a difficulty and a possible response accuracy variability. We also present preliminary EEG results in offline BCI mode. The obtained results validate a thesis, that spatial auditory only paradigm performs as good as the traditional visual and audiovisual speller BCI tasks.

preprint2012arXiv

Spatial Auditory BCI Paradigm Utilizing N200 and P300 Responses

The paper presents our recent results obtained with a new auditory spatial localization based BCI paradigm in which the ERP shape differences at early latencies are employed to enhance the traditional P300 responses in an oddball experimental setting. The concept relies on the recent results in auditory neuroscience showing a possibility to differentiate early anterior contralateral responses to attended spatial sources. Contemporary stimuli-driven BCI paradigms benefit mostly from the P300 ERP latencies in so called "aha-response" settings. We show the further enhancement of the classification results in spatial auditory paradigms by incorporating the N200 latencies, which differentiate the brain responses to lateral, in relation to the subject head, sound locations in the auditory space. The results reveal that those early spatial auditory ERPs boost online classification results of the BCI application. The online BCI experiments with the multi-command BCI prototype support our research hypothesis with the higher classification results and the improved information-transfer-rates.

preprint2012arXiv

The Spatial Real and Virtual Sound Stimuli Optimization for the Auditory BCI

The paper presents results from a project aiming to create horizontally distributed surround sound sources and virtual sound images as auditory BCI (aBCI) stimuli. The purpose is to create evoked brain wave response patterns depending on attended or ignored sound directions. We propose to use a modified version of the vector based amplitude panning (VBAP) approach to achieve the goal. The so created spatial sound stimulus system for the novel oddball aBCI paradigm allows us to create a multi-command experimental environment with very encouraging results reported in this paper. We also present results showing that a modulation of the sound image depth changes also the subject responses. Finally, we also compare the proposed virtual sound approach with the traditional one based on real sound sources generated from the real loudspeaker directions. The so obtained results confirm the hypothesis of the possibility to modulate independently the brain responses to spatial types and depths of sound sources which allows for the development of the novel multi-command aBCI.

preprint2012arXiv

Vibrotactile Stimulus Frequency Optimization for the Haptic BCI Prototype

The paper presents results from a psychophysical study conducted to optimize vibrotactile stimuli delivered to subject finger tips in order to evoke the somatosensory responses to be utilized next in a haptic brain computer interface (hBCI) paradigm. We also present the preliminary EEG evoked responses for the chosen stimulating frequency. The obtained results confirm our hypothesis that the hBCI paradigm concept is valid and it will allow for rapid stimuli presentation in order to improve information-transfer-rate (ITR) of the BCI.