Source author record

Tobias Flick

Tobias Flick appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

Gbit/s Data Transmission on Carbon Fibres

Data transmission at the upgraded Large Hadron Collider experiments, foreseen for mid 2020s will be in the multi Gbit/s range per connection for the innermost detector layers. This paper reports on first tests on the possible use of carbon cables for electrical data transmission close to the interaction point. Carbon cables have the potential advantage of being light, having a low activation and easy integration into the detector components close to the interaction point. In these tests commercially available carbon cables were used, in which the filaments had a very thin nickel coating. For these cables data rates beyond 1 Gbit/s over more than 1m with an error rate of less than 10^{-12} could be transmitted. The characteristics of the cables have been measured in terms of S-parameters and could be reproduced with a Spice model. Some outlook on potential further improvements is presented.

preprint2005arXiv

Validation Studies of the ATLAS Pixel Detector Control System

The ATLAS pixel detector consists of 1744 identical silicon pixel modules arranged in three barrel layers providing coverage for the central region, and three disk layers on either side of the primary interaction point providing coverage of the forward regions. Once deployed into the experiment, the detector will employ optical data transfer, with the requisite powering being provided by a complex system of commercial and custom-made power supplies. However, during normal performance and production tests in the laboratory, only single modules are operated and electrical readout is used. In addition, standard laboratory power supplies are used. In contrast to these normal tests, the data discussed here was obtained from a multi-module assembly which was powered and read out using production items: the optical data path, the final design power supply system using close to final services, and the Detector Control System (DCS). To demonstrate the functionality of the pixel detector system a stepwise transition was made from the normal laboratory readout and power supply systems to the ones foreseen for the experiment, with validation of the data obtained at each transition.