Source author record

Tengfei Wu

Tengfei Wu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Single-shot diffraction-limited imaging through scattering layers via bispectrum analysis

Recently introduced speckle-correlations based techniques enable noninvasive imaging of objects hidden behind scattering layers. In these techniques the hidden object Fourier amplitude is retrieved from the scattered light autocorrelation, and the lost Fourier phase is recovered via iterative phase-retrieval algorithms, which suffer from convergence to wrong local-minima solutions and cannot solve ambiguities in object-orientation. Here, inspired by notions used in astronomy, we experimentally demonstrate that in addition to Fourier amplitude, the object phase information is naturally and inherently encoded in scattered light bispectrum (the Fourier transform of triple-correlation), and can also be extracted from a single high-resolution speckle pattern, based on which we present a single-shot imaging scheme to deterministically and unambiguously retrieve diffraction-limited images of objects hidden behind scattering layers.

preprint2020arXiv

Non-invasive single-shot recovery of point-spread function of a memory effect based scattering imaging system

Accessing the point-spread function (PSF) of a complex optical system is important for a variety of imaging applications. However, placing an invasive point source is often impractical, and estimating it blindly with multiple frames is slow and requires a complex non-linear optimization. Here, we introduce a simple single-shot method to non-invasively recover the accurate PSF of an isoplanatic imaging system, in the context of multiple light scattering. Our approach is based on the reconstruction of any unknown sparse hidden object using the autocorrelation imaging technique, followed by a deconvolution with a blur kernel derived from the statistics of a speckle pattern. A deconvolution on the camera image then retrieves the accurate PSF of the system, enabling further imaging applications. We demonstrate numerically and experimentally the effectiveness of this approach compared to previous deconvolution techniques.

preprint2020arXiv

Time-Stretched Femtosecond Lidar Using Microwave Photonic Signal Processing

A real-time ranging lidar with 0.1 Mega Hertz update rate and few-micrometer resolution incorporating dispersive Fourier transformation and instantaneous microwave frequency measurement is proposed and demonstrated. As time-stretched femtosecond laser pulse passing through an all-fiber Mach-Zehnder Interferometer, where the detection light beam is inserted into the optical path of one arm, the displacement is encoded to the frequency variation of the temporal interferogram. To deal with the challenges in storage and real-time processing of the microwave pulse generated on a photodetector, we turn to all-optical signal processing. A carrier wave is modulated by the time-domain interferogram using an intensity modulator. After that, the frequency variation of the microwave pulse is uploaded to the first order sidebands. Finally, the frequency shift of the sidebands is turned into transmission change through a symmetric-locked frequency discriminator. In experiment, A real-time ranging system with adjustable dynamic range and detection sensitivity is realized by incorporating a programmable optical filter. Standard deviation of 7.64 μm, overall mean error of 19.10 μm over 15 mm detection range and standard deviation of 37.73 μm, overall mean error of 36.63 μm over 45 mm detection range are obtained respectively.