Source author record

Takayuki Tomaru

Takayuki Tomaru appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

A laser interferometer accelerometer for vibration sensitive cryogenic experiments

Monitoring motion originating from ultra low-temperature cooling systems like cryocoolers is important for vibration sensitive cryogenic experiments like KAGRA. Since no commercial cryogenic accelerometers are available, we developed a compact self-calibrating accelerometer with a Michelson interferometer readout for cryogenic use. Change in calibration factor and drop in interferometer output originating from temperature drop were the main concerns which were tackled. Sensitivity of $3.38\times10^{-11}$ m/$\sqrt{\mathrm{Hz}}$ at 1 Hz was achieved at 300 K. The accelerometer was tested inside the KAGRA cryostat; showed stable operation down to 12 K in 0.1-100 Hz band with only 1% visibility drop. Our accelerometer can be employed in low vibration cryogenic environment for a multitude of applications.

preprint2022arXiv

Vibration Analysis of KAGRA Cryostat at Cryogenic Temperature

KAGRA uses cryogenics to cool its sapphire test masses down to 20 K to reduce the thermal noise. However, cryocooler vibration and structural resonances of the cryostat couple to test mass and can contaminate the detector sensitivity. We performed vibration analysis of the cooling system at cryogenic temperature to study its impact on detector sensitivity. Our measurement show shield vibration below 1 Hz is not impacted by cryocooler operation or structural resonances and follows ground motion. The noise floor of the shield in 1-100 Hz was observed to be 2-3 order of magnitude larger than seismic motion even without cryocooler operation. The operation of cryocoolers does not change the noise floor, but 2.0 Hz peaks and their harmonics were observed over the entire spectrum (1-100 Hz). These results were used to calculate the coupling of cooling system vibration to the test mass. We conclude that vibration from the cooling system does not limit KAGRA design sensitivity.

preprint2016arXiv

POLARBEAR Constraints on Cosmic Birefringence and Primordial Magnetic Fields

We constrain anisotropic cosmic birefringence using four-point correlations of even-parity $E$-mode and odd-parity $B$-mode polarization in the cosmic microwave background measurements made by the POLARization of the Background Radiation (POLARBEAR) experiment in its first season of observations. We find that the anisotropic cosmic birefringence signal from any parity-violating processes is consistent with zero. The Faraday rotation from anisotropic cosmic birefringence can be compared with the equivalent quantity generated by primordial magnetic fields if they existed. The POLARBEAR nondetection translates into a 95% confidence level (C.L.) upper limit of 93 nanogauss (nG) on the amplitude of an equivalent primordial magnetic field inclusive of systematic uncertainties. This four-point correlation constraint on Faraday rotation is about 15 times tighter than the upper limit of 1380 nG inferred from constraining the contribution of Faraday rotation to two-point correlations of $B$-modes measured by Planck in 2015. Metric perturbations sourced by primordial magnetic fields would also contribute to the $B$-mode power spectrum. Using the POLARBEAR measurements of the $B$-mode power spectrum (two-point correlation), we set a 95% C.L. upper limit of 3.9 nG on primordial magnetic fields assuming a flat prior on the field amplitude. This limit is comparable to what was found in the Planck 2015 two-point correlation analysis with both temperature and polarization. We perform a set of systematic error tests and find no evidence for contamination. This work marks the first time that anisotropic cosmic birefringence or primordial magnetic fields have been constrained from the ground at subdegree scales.

preprint2016arXiv

Two-layer anti-reflection coating with mullite and polyimide foam for large-diameter cryogenic infrared filters

We have developed a novel two-layer anti-reflection (AR) coating method for large-diameter infrared (IR) filters made of alumina, for the use at cryogenic temperatures in millimeter wave measurements. Thermally- sprayed mullite and polyimide foam (Skybond Foam) are used as the AR material. An advantage of the Skybond Foam is that the index of refraction is chosen between 1.1 and 1.7 by changing the filling factor. Combination with mullite is suitable for wide-band millimeter wave measurements with sufficient IR cutoff capability. We present the material properties, fabrication of a large-diameter IR filter made of alumina with this AR coating method, and characterizations at cryogenic temperatures. This technology can be applied to a low-temperature receiver system with a large-diameter focal plane for next-generation cosmic microwave background (CMB) polarization measurements, such as POLARBEAR-2 (PB-2).

preprint2014arXiv

Cryogenic infrared filter made of alumina for use at millimeter wavelength

We propose a high thermal conductivity infrared (IR) filter using alumina for use in millimeter wave detection systems. We constructed a prototype two-layer anti-reflection (AR) coated alumina filter with a diameter of 100mm and a thickness of 2mm, and characterized its thermal and optical properties. The transmittance of this filter at 95GHz and 150GHz is 97% and 95% while the estimated 3dB cutoff frequency is at 450GHz. The high thermal conductivity of alumina minimizes thermal gradients. We measure a differential temperature of only 0.21K between the center and the edge of the filter when it is mounted on a thermal anchor of 77K. We also constructed a thermal model based on the prototype filter and analyzed the scalability of the filter diameter. We conclude that temperature increase at the center of alumina IR filter is less than 6K even with a large diameter of 500mm, when the temperature at the edge of the filter is 50K. This is suitable for an application to a large-throughput next-generation cosmic microwave background (CMB) polarization experiment, such as POLARBEAR-2 (PB-2).

preprint2013arXiv

Adaptation of frequency-domain readout for Transition Edge Sensor bolometers for the POLARBEAR-2 Cosmic Microwave Background experiment

The POLARBEAR-2 CosmicMicrowave Background (CMB) experiment aims to observe B-mode polarization with high sensitivity to explore gravitational lensing of CMB and inflationary gravitational waves. POLARBEAR-2 is an upgraded experiment based on POLARBEAR-1, which had first light in January 2012. For POLARBEAR-2, we will build a receiver that has 7,588 Transition Edge Sensor (TES) bolometers coupled to two-band (95 and 150 GHz) polarization-sensitive antennas. For the large array's readout, we employ digital frequency-domain multiplexing and multiplex 32 bolometers through a single superconducting quantum interference device (SQUID). An 8-bolometer frequency-domain multiplexing readout has been deployed on POLARBEAR-1 experiment. Extending that architecture to 32 bolometers requires an increase in the bandwidth of the SQUID electronics to 3 MHz. To achieve this increase in bandwidth, we use Digital Active Nulling (DAN) on the digital frequency multiplexing platform. In this paper, we present requirements and improvements on parasitic inductance and resistance of cryogenic wiring and capacitors used for modulating bolometers. These components are problematic above 1 MHz. We also show that our system is able to bias a bolometer in its superconducting transition at 3 MHz.