Source author record

T. Ye

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
5topics
4close collaborators

Published work

3 publications

preprint2022arXiv

New Measurements of the Beam-Normal Single Spin Asymmetry in Elastic Electron Scattering Over a Range of Spin-0 Nuclei

We report precision determinations of the beam normal single spin asymmetries (AnA_n) in the elastic scattering of 0.95 and 2.18~GeV electrons off 12^{12}C, 40^{40}Ca, 48^{48}Ca, and 208^{208}Pb at very forward angles where the most detailed theoretical calculations have been performed. The first measurements of AnA_n for 40^{40}Ca and 48^{48}Ca are found to be similar to that of 12^{12}C, consistent with expectations thus demonstrating the validity of theoretical calculations for nuclei with Z~≤20\leq20. We also report AnA_n for 208^{208}Pb at two new momentum transfers (Q2^2) extending the previous measurement. Our new data confirm the surprising result previously reported, with all three data points showing significant disagreement with the results from the Z≤20Z\leq 20 nuclei. These data confirm our basic understanding of the underlying dynamics that govern AnA_n for nuclei containing ≲50\lesssim 50 nucleons, but point to the need for further investigation to understand the unusual AnA_n behaviour discovered for scattering off 208^{208}Pb.

preprint2022arXiv

Precision Determination of the Neutral Weak Form Factor of 48^{48}Ca

We report a precise measurement of the parity-violating asymmetry APVA_{\rm PV} in the elastic scattering of longitudinally polarized electrons from 48Ca^{48}{\rm Ca}. We measure APV=2668±106 (stat)±40 (syst)A_{\rm PV} =2668\pm 106\ {\rm (stat)}\pm 40\ {\rm (syst)} parts per billion, leading to an extraction of the neutral weak form factor FW(q=0.8733F_{\rm W} (q=0.8733 fm−1)=0.1304±0.0052 (stat)±0.0020 (syst)^{-1}) = 0.1304 \pm 0.0052 \ {\rm (stat)}\pm 0.0020\ {\rm (syst)} and the charge minus the weak form factor Fch−FW=0.0277±0.0055F_{\rm ch} - F_{\rm W} = 0.0277\pm 0.0055. The resulting neutron skin thickness Rn−Rp=0.121±0.026 (exp)±0.024 (model)R_n-R_p=0.121 \pm 0.026\ {\rm (exp)} \pm 0.024\ {\rm (model)}~fm is relatively thin yet consistent with many model calculations. The combined CREX and PREX results will have implications for future energy density functional calculations and on the density dependence of the symmetry energy of nuclear matter.

preprint2014arXiv

PandaX: A Liquid Xenon Dark Matter Experiment at CJPL

PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and 136^{136}Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time projection chamber will be staged, with the first stage accommodating a target mass of about 120\,kg. In stage II, the target mass will be increased to about 0.5\,ton. In the final stage, the detector can be upgraded to a multi-ton target mass. In this paper a detailed description of the stage-I detector design and performance results established during the commissioning phase is presented.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.