Source author record

T. Tanimori

T. Tanimori appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

20works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

20 published item(s)

preprint2016arXiv

Readout technologies for directional WIMP Dark Matter detection

The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.

preprint2015arXiv

An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays

Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$ persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be indeed helpful to reduce the background under conditions similar to space. Accordingly the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg cm$^{-2}$ s$^{-1}$ at 1 MeV.

preprint2015arXiv

Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam

We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.

preprint2014arXiv

Development of a 30 cm-cube Electron-Tracking Compton Camera for the SMILE-II Experiment

To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV. As the greatest impact of this work, a gamma-ray detection efficiency on the order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one order of magnitude higher than our previous experiment. This angular resolution and detection efficiency enables us to detect the Crab Nebula at the 5 sigma level with several hours observation at balloon altitude in middle latitude. Furthermore, good consistency of efficiencies between this performance test and simulation including only physical processes has a large importance; it means we achieve nearly 100% detection of Compton recoil electrons. Thus, our estimation of enhancements by upgrades of the detector is more dependable. We are planning to confirm the imaging capability of the ETCC by observation of celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment II). The SMILE-II and following SMILE-III project will be an important key of sub-MeV/MeV gamma-ray astronomy.

preprint2012arXiv

Neutron imaging detector based on the muPIC micro-pixel chamber

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.

preprint2012arXiv

Searches for very high energy gamma rays from blazars with CANGAROO-III telescope in 2005-2009

We have searched for very high energy (VHE) gamma rays from four blazars using the CANGAROO-III imaging atmospheric Cherenkov telescope. We report the results of the observations of H 2356-309, PKS 2155-304, PKS 0537-441, and 3C 279, performed from 2005 to 2009, applying a new analysis to suppress the effects of the position dependence of Cherenkov images in the field of view. No significant VHE gamma ray emission was detected from any of the four blazars. The GeV gamma-ray spectra of these objects were obtained by analyzing Fermi/LAT archival data. Non-simultaneous wide range (radio to VHE gamma-ray bands) spectral energy distributions (SEDs) including CANGAROO-III upper limits, GeV gamma-ray spectra, and archival data are discussed using a one-zone synchrotron self-Compton (SSC) model in combination with a external Compton (EC) radiation. The HBLs (H 2356-309 and PKS 2155-304) can be explained by a simple SSC model, and PKS 0537-441 and 3C 279 are well modeled by a combination of SSC and EC model. We find a consistency with the blazar sequence in terms of strength of magnetic field and component size.

preprint2011arXiv

CANGAROO-III observation of TeV gamma rays from the unidentified gamma-ray source HESS J1614-518

We report the detection, with the CANGAROO-III imaging atmospheric Cherenkov telescope array, of a very high energy gamma-ray signal from the unidentified gamma-ray source HESS J1614-518, which was discovered in the H.E.S.S. Galactic plane survey. Diffuse gamma-ray emission was detected above 760 GeV at the 8.9 sigma level during an effective exposure of 54 hr from 2008 May to August. The spectrum can be represented by a power-law: 8.2+-2.2_{stat}+-2.5_{sys}x10^{-12}x (E/1TeV)^{-Gamma} cm^{-2} s^{-1} TeV^{-1} with a photon index Gamma of 2.4+-0.3_{stat}+-0.2_{sys}, which is compatible with that of the H.E.S.S. observations. By combining our result with multi-wavelength data, we discuss the possible counterparts for HESS J1614-518 and consider radiation mechanisms based on hadronic and leptonic processes for a supernova remnant, stellar winds from massive stars, and a pulsar wind nebula. Although a leptonic origin from a pulsar wind nebula driven by an unknown pulsar remains possible, hadronic-origin emission from an unknown supernova remnant is preferred.

preprint2009arXiv

CANGAROO-III Observation of TeV Gamma Rays from the vicinity of PSR B1 706-44

Observation by the CANGAROO-III stereoscopic system of the Imaging Cherenkov Telescope has detected extended emission of TeV gamma rays in the vicinity of the pulsar PSR B1706$-$44. The strength of the signal observed as gamma-ray-like events varies when we apply different ways of emulating background events. The reason for such uncertainties is argued in relevance to gamma-rays embedded in the "off-source data", that is, unknown sources and diffuse emission in the Galactic plane, namely, the existence of a complex structure of TeV gamma-ray emission around PSR B1706$-$44.

preprint2009arXiv

CANGAROO-III search for TeV Gamma-rays from two clusters of galaxies

Because accretion and merger shocks in clusters of galaxies may accelerate particles to high energies, clusters are candidate sites for the origin of ultra-high-energy (UHE) cosmic-rays. A prediction was presented for gamma-ray emission from a cluster of galaxies at a detectable level with the current generation of imaging atmospheric Cherenkov telescopes. The gamma-ray emission was produced via inverse Compton upscattering of cosmic microwave background (CMB) photons by electron-positron pairs generated by collisions of UHE cosmic rays in the cluster. We observed two clusters of galaxies, Abell 3667 and Abell 4038, searching for very-high-energy gamma-ray emission with the CANGAROO-III atmospheric Cherenkov telescope system in 2006. The analysis showed no significant excess around these clusters, yielding upper limits on the gamma-ray emission. From a comparison of the upper limit for the north-west radio relic region of Abell 3667 with a model prediction, we derive a lower limit for the magnetic field of the region of ~0.1 micro G. This shows the potential of gamma-ray observations in studies of the cluster environment. We also discuss the flux upper limit from cluster center regions using a model of gamma-ray emission from neutral pions produced in hadronic collisions of cosmic-ray protons with the intra-cluster medium (ICM). The derived upper limit of the cosmic-ray energy density within this framework is an order of magnitude higher than that of our Galaxy.

preprint2009arXiv

Search for VHE gamma rays from SS433/W50 with the CANGAROO-II telescope

SS433, located at the center of the supernova remnant W50, is a close proximity binary system consisting of a compact star and a normal star. Jets of material are directed outwards from the vicinity of the compact star symmetrically to the east and west. Non-thermal hard X-ray emission is detected from lobes lying on both sides. Shock accelerated electrons are expected to generate sub-TeV gamma rays through the inverse-Compton process in the lobes. Observations of the western X-ray lobe region of SS433/W50 system have been performed to detect sub-TeV gamma-rays using the 10m CANGAROO-II telescope in August and September, 2001, and July and September, 2002. The total observation times are 85.2 hours for ON source, and 80.8 hours for OFF source data. No significant excess of sub-TeV gamma rays has been found at 3 regions of the western X-ray lobe of SS433/W50 system. We have derived 99% confidence level upper limits to the fluxes of gamma rays and have set constraints on the strengths of the magnetic fields assuming the synchrotron/inverse-Compton model for the wide energy range of photon spectrum from radio to TeV. The derived lower limits are 4.3 microgauss for the center of the brightest X-ray emission region and 6.3 microgauss for the far end from SS433 in the western X-ray lobe. In addition, we suggest that the spot-like X-ray emission may provide a major contribution to the hardest X-ray spectrum in the lobe.

preprint2009arXiv

The case for a directional dark matter detector and the status of current experimental efforts

We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.

preprint2003arXiv

Development of a time projection chamber with micro pixel electrodes

A time projection chamber (TPC) based on a gaseous chamber with micro pixel electrodes (micro-PIC) has been developed for measuring three-dimensional tracks of charged particles. The micro-PIC with a detection area of 10 cm square consists of a double-sided printing circuit board. Anode pixels are formed with 0.4 mm pitch on strips aligned perpendicular to the cathode strips in order to obtain a two-dimensional position. In the TPC with drift length of 8 cm, 4 mm wide field cage electrodes are aligned at 1mm spaces and a uniform electric field of about 0.4 kV/cm is produced. For encoding of the three-dimensional position a synchronous readout system has been developed using Field Programmable Gate Arrays with 40 MHz clock. This system enables us to reconstruct the three-dimensional track of the particle at successive points like a cloud chamber even at high event rate. The drift velocity of electrons in the TPC was measured with the tracks of cosmic muons for three days, during which the TPC worked stably with the gas gain of 3000. With a radioisotope of gamma-ray source the three-dimensional track of a Compton scattered electron was taken successfully.

preprint2003arXiv

Performance of large area Micro Pixel Chamber

A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536 pixel anodes of 400um pitch on a 100um thick insulating substrate. Achieved energy resolution was 30% (FWHM) at 5.9keV, and a gas gain of 7000 was obtained with argon ethane (8:2) gas mixture. This gain is high enough to detect minimum ionizing particles with such a small electrode pitch. Although several discharges occurred during 65 hours continuous operation, the detectors have kept stable operation with high gain. The micro-PIC is a useful detector for many applications e.g. X-ray, gamma ray, and charged particle imaging. The micro electrode structure allows us to measure directions of primary electrons due to incident X-rays or gamma rays, which provide a strong method for X-ray polarimetry and gamma-ray imaging.

preprint1999arXiv

TeV gamma-ray observations of three X-ray selected BL Lacs

Despite extensive surveys of extragalactic TeV gamma-ray candidates only 3 sources have so far been detected. All three are northern hemisphere objects and all three are low-redshift X-ray selected BL Lacs (XBLs). In this paper we present the results of observations of the three nearest southern hemisphere XBLs (PKS0548-322, PKS2005-489 and PKS2155-304) with the CANGAROO 3.8m imaging telescope. During the period of observation we estimate that the threshold of the 3.8m telescope was around 1.5TeV. Searches for both steady and short timescale emission have been performed for each source. Additionally, we are able to monitor the X-ray state of each source on a daily basis and we have made contemporaneous measurements of optical activity for PKS0548-322 and PKS2155-304.

preprint1999arXiv

TeV observations of Centaurus A

We have searched for TeV gamma-rays from Centaurus A and surrounding region out to +/- 1.0 deg using the CANGAROO 3.8m telescope. No evidence for TeV gamma-ray emission was observed from the search region, which includes a number of interesting features located away from the tracking centre of our data. The 3 sigma upper limit to the flux of gamma-rays above 1.5 TeV from an extended source of radius 14' centred on Centaurus A is 1.28e-11 photons cm^-2 s^-1.

preprint1998arXiv

Discovery of TeV Gamma Rays from SN1006: Further Evidence for the SNR Origin of Cosmic Rays

This paper reports the first discovery of TeV gamma-ray emission from a supernova remnant made with the CANGAROO 3.8 m Telescope. TeV gamma rays were detected at the sky position and extension coincident with the north-east (NE) rim of shell-type Supernova remnant (SNR) SN1006 (Type Ia). SN1006 has been a most likely candidate for an extended TeV Gamma-ray source, since the clear synchrotron X-ray emission from the rims was recently observed by ASCA (Koyama et al. 1995), which is a strong evidence of the existence of very high energy electrons up to hundreds of TeV in the SNR. The observed TeV gamma-ray flux was $(2.4\pm 0.5(statistical) \pm 0.7(systematic)) \times 10^{-12}$ cm$^{-2}$ s$^{-1}$ ($\ge 3.0\pm 0.9$ TeV) and $ (4.6\pm 0.6 \pm 1.4) \times 10^{-12}$ cm$^{-2}$ s$^{-1}$ ($\ge 1.7\pm 0.5$ TeV) from the 1996 and 1997 observations, respectively. Also we set an upper limit on the TeV gamma-ray emission from the SW rim, estimated to be $ 1.1 \times 10^{-12}$ cm$^{-2}$ s$^{-1}$ ($\ge 1.7\pm 0.5$ TeV, 95% CL) in the 1997 data. The TeV gamma rays can be attributed to the 2.7 K cosmic background photons up-scattered by electrons of energies up to about 10$^{14}$ eV by the inverse Compton (IC) process. The observed flux of the TeV gamma rays, together with that of the non-thermal X-rays, gives firm constraints on the acceleration process in the SNR shell; a magnetic field of $6.5\pm2$ $μ$G is inferred from both the synchrotron X-rays and inverse Compton TeV gamma-rays, which gives entirely consistent mechanisms that electrons of energies up to 10$^{14}$ eV are produced via the shock acceleration in SN1006.

preprint1998arXiv

TeV gamma-ray observations of southern BL Lacs with the CANGAROO 3.8m Imaging Telescope

Observational and theoretical results indicate that low-redshift BL Lacertae objects are the most likely extragalactic sources to be detectable at TeV energies. In this paper we present the results of observations of 4 BL Lacertae objects (PKS0521-365, EXO0423.4-0840, PKS2005-489 and PKS2316-423) made between 1993 and 1996 with the CANGAROO 3.8m imaging Cherenkov telescope. During the period of these observations the gamma-ray energy threshold of the 3.8m telescope was ~2TeV. Searches for steady long-term emission have been made, and, inspired by the TeV flares detected from Mkn421 and Mkn501, a search on a night-by-night timescale has also been performed for each source. Comprehensive Monte Carlo simulations are used to estimate upper limits for both steady and short timescale emission.

preprint1997arXiv

Detection of Gamma Rays of Up to 50 TeV From the Crab Nebula

Gamma rays with energies greater than 7 TeV from the Crab pulsar/nebula have been observed at large zenith angles, using the Imaging Atmospheric Technique from Woomera, South Australia. CANGAROO data taken in 1992, 1993 and 1995 indicate that the energy spectrum extends up to at least 50 TeV, without a change of the index of the power law spectrum. The observed differential spectrum is \noindent $(2.01\pm 0.36)\times 10^{-13}(E/{7 TeV})^{-2.53 \pm 0.18} TeV^{-1}cm^{-2}s^{-1}$ between 7 TeV and 50 TeV. There is no apparent cut-off. The spectrum for photon energies above $\sim$10 TeV allows the maximum particle acceleration energy to be inferred, and implies that this unpulsed emission does not originate near the light cylinder of the pulsar, but in the nebula where the magnetic field is not strong enough to allow pair creation from the TeV photons. The hard gamma-ray energy spectrum above 10 TeV also provides information about the varying role of seed photons for the inverse Compton process at these high energies, as well as a possible contribution of $π^{\circ}$-gamma rays from proton collisions.

preprint1997arXiv

Very High Energy Gamma Rays from the Vela Pulsar Direction

We have observed the Vela pulsar region at TeV energies using the 3.8 m imaging Cherenkov telescope near Woomera, South Australia between January 1993 and March 1995. Evidence of an unpulsed gamma-ray signal has been detected at the 5.8 sigma level. The detected gamma-ray flux is (2.9 +/- 0.5 +/- 0.4) x 10^-12 photons cm^-2 sec^-1 above 2.5 +/- 1.0 TeV and the signal is consistent with steady emission over the two years. The gamma-ray emission region is offset from the Vela pulsar position to the southeast by about 0.13 deg. No pulsed emission modulated with the pulsar period has been detected and the 95 % confidence flux upper limit to the pulsed emission from the pulsar is (3.7 +/- 0.7) x 10^-13 photons cm^-2 sec^-1 above 2.5 +/- 1.0 TeV.