Researcher profile

T. P. Gorringe

T. P. Gorringe contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Performance of the Muon $g-2$ calorimeter and readout systems measured with test beam data

A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS data acquisition environment. The entire system performance was evaluated using 2.5 - 5 GeV electrons at the End Station Test Beam at SLAC. This paper includes a description of the individual subsystems and the results of measurements of the energy response and resolution, energy-scale stability, timing resolution, and spatial uniformity. All measured performances meet or exceed the $g-2$ experimental requirements. Based on the success of the tests, the complete production of the required 24 calorimeter stations has been made and installation into the main experiment is complete. Furthermore, the calorimeter response measurements determined here informed the design of the reconstruction algorithms that are now employed in the running $g-2$ experiment.

preprint2013arXiv

MuLan Measurement of the Positive Muon Lifetime and Determination of the Fermi Constant

We report results from the MuLan measurement of the positive muon lifetime. The experiment was conducted at the Paul Scherrer Institute using a time-structured surface muon beam and a segmented plastic scintillator array. Two different in-vacuum muon stopping targets were used: a ferromagnetic foil with a large internal magnetic field and a quartz crystal in a moderate external magnetic field. From a total of 1.6 x 10^{12} decays, we obtained the muon lifetime tau_mu = 2196980.3(2.2) ps (1.0 ppm) and Fermi constant G_F = 1.1663787(6) x 10^{-5} GeV^{-2} (0.5 ppm).

preprint1996arXiv

Radiative Muon Capture on Hydrogen and the Induced Pseudoscalar Coupling

The first measurement of the elementary process $μ^- p \rightarrow ν_μ n γ$ is reported. A photon pair spectrometer was used to measure the partial branching ratio ($2.10 \pm 0.22) \times 10^{-8}$ for photons of k > 60 MeV. The value of the weak pseudoscalar coupling constant determined from the partial branching ratio is $g_p(q^{2}=-0.88m_μ^2) = (9.8 \pm 0.7 \pm 0.3) \cdot g_a(0)$, where the first error is the quadrature sum of statistical and systematic uncertainties and the second error is due to the uncertainty in $λ_{op}$, the decay rate of the ortho to para $p μp$ molecule. This value of g_p is $\sim$1.5 times the prediction of PCAC and pion-pole dominance.