Researcher profile

T. Mitani

T. Mitani contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2012arXiv

Performance of a 250L liquid Argon TPC for sub-GeV charged particle identification

We have constructed a liquid Argon TPC detector with fiducial mass of 150 kg as a part of the R&D program of the next generation neutrino and nucleon decay detector. This paper describes a study of particle identification performance of the detector using well-defined charged particles (pions, kaons, and protons) with momentum of ~800 MeV/$c$ obtained at J-PARC K1.1BR beamline.

preprint2011arXiv

A tagged low-momentum kaon test-beam exposure with a 250L LAr TPC (J-PARC T32)

At the beginning of 2010, we presented at the J-PARC PAC an R$&$D program towards large (100 kton scale) liquid argon TPCs, suitable to investigate, in conjunction with the J-PARC neutrino beam, the possibility of CP violation in the neutrino sector and to search for nucleon decay. As a first step we proposed a test experiment to identify and measure charged kaons, including their decays, in liquid argon. The detector, a 250L LAr TPC, is exposed to charged kaons, in a momentum range of 540-800 MeV/c, in the K1.1BR beamline of the J-PARC slow extraction facility. This is especially important to estimate efficiency and background for nucleon decay searches in the charged kaon mode ($p \rightarrow \barν K^+$, etc.), where the kaon momentum is expected to be in the few hundred MeV/c range. A prototype setup has been exposed in the K1.1BR beamline in the fall of 2010. This paper describes the capabilities of the beamline, the construction and setting up of the detector prototype, along with some preliminary results.

preprint2006arXiv

Hard X-ray Detector (HXD) on Board Suzaku

The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large effective area for sub-MeV to MeV gamma-rays. They work as an excellent gamma-ray burst monitor with limited angular resolution (~5 degree). The on-board signal-processing system and the data transmitted to the ground are also described.

preprint2006arXiv

In-Orbit Performance of the Hard X-ray Detector on board Suzaku

The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10-600 keV, energy resolutions of ~4 keV (FWHM) at 40 keV and ~11% at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of PIN-Si diodes have been stable within 1% for half a year, and those of scintillators have decreased by 5-20%. The residual non-X-ray background of the HXD is the lowest among past non-imaging hard X-ray instruments in energy ranges of 15-70 and 150-500 keV. We provide accurate calibrations of energy responses, angular responses, timing accuracy of the HXD, and relative normalizations to the X-ray CCD cameras using multiple observations of the Crab Nebula.

preprint2004arXiv

Performance of a Low Noise Front-end ASIC for Si/CdTe Detectors in Compton Gamma-ray Telescope

Compton telescopes based on semiconductor technologies are being developed to explore the gamma-ray universe in an energy band 0.1--20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of such Compton telescopes is the high energy resolution that is crucial for high angular resolution and high background rejection capability. The energy resolution around 1 keV is required to approach physical limit of the angular resolution due to Doppler broadening. We have developed a low noise front-end ASIC (Application-Specific Integrated Circuit), VA32TA, to realize this goal for the readout of Double-sided Silicon Strip Detector (DSSD) and Cadmium Telluride (CdTe) pixel detector which are essential elements of the semiconductor Compton telescope. We report on the design and test results of the VA32TA. We have reached an energy resolution of 1.3 keV (FWHM) for 60 keV and 122 keV at 0 degree C with a DSSD and 1.7 keV (FWHM) with a CdTe detector.