Source author record

T. Ido

T. Ido appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

Overcoming the space-charge dilemma in low-energy heavy ion beams via a multistage acceleration lens system

Low-energy heavy-ion beams are fundamentally limited by severe space-charge divergence, which constrains the transportable beam current to a few microamperes in conventional electrostatic accelerators. This limitation is particularly critical for high-mass ions, where the generalized perveance increases rapidly because of their low velocity. Here, we demonstrate that this apparent space-charge limit can be overcome by shaping the electrostatic potential configuration of an existing multistage accelerator, thereby transforming the acceleration column itself into a combined acceleration-focusing column. By optimizing the interstage voltage configuration, a strong electrostatic lens effect is superimposed on the accelerating field to counteract space-charge-driven expansion. We formulate a generalized design framework that quantitatively maps the transport 'design window' in terms of beam current, ion mass, and acceleration voltage. For gold ions at 64 keV, this approach enables stable transport of beam currents exceeding 100 microA, more than an order of magnitude higher than the conventional limit. Numerical phase-space analysis shows that this improvement is achieved by prioritizing envelope control over emittance preservation, a trade-off intrinsic to space-charge-dominated regimes. Our results establish a universal and practical guideline for high-current heavy-ion beam transport, relevant to fusion plasma diagnostics, ion implantation, and massive molecular ion applications.

preprint2014arXiv

Direct comparison of optical lattice clocks with an intercontinental baseline of 9 000 km

We have demonstrated a direct frequency comparison between two $^{87}{\rm Sr}$ lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique based on the carrier phase was employed for a direct comparison with a baseline of 9 000 km between Japan and Germany. A clock comparison was achieved for 83 640 s resulting in a fractional difference of $(1.1\pm1.6) \times 10^{-15}$, where the statistical part is the biggest contribution to the uncertainty. This measurement directly confirms the agreement of the two optical clocks on an intercontinental scale.

preprint2012arXiv

Stability Transfer between Two Clock Lasers Operating at Different Wavelengths for Absolute Frequency Measurement of Clock Transition in 87Sr

We demonstrated transferring the stability of one highly stable clock laser operating at 729 nm to another less stable laser operating at 698 nm. The two different wavelengths were bridged using an optical frequency comb. The improved stability of the clock laser at 698 nm enabled us to evaluate the systematic frequency shifts of the Sr optical lattice clock with shorter averaging time. We determined the absolute frequency of the clock transition 1S0 - 3P0 in 87Sr to be 429 228 004 229 873.9 (1.4) Hz referenced to the SI second on the geoid via International Atomic Time (TAI).