Source author record

T. Chattopadhyay

T. Chattopadhyay appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Probing into emission mechanisms of GRB 190530A using time-resolved spectra and polarization studies: Synchrotron Origin?

Multi-pulsed GRB 190530A, detected by the GBM and LAT onboard \fermi, is the sixth most fluent GBM burst detected so far. This paper presents the timing, spectral, and polarimetric analysis of the prompt emission observed using \AstroSat and \fermi to provide insight into the prompt emission radiation mechanisms. The time-integrated spectrum shows conclusive proof of two breaks due to peak energy and a second lower energy break. Time-integrated (55.43 $\pm$ 21.30 \%) as well as time-resolved polarization measurements, made by the Cadmium Zinc Telluride Imager (CZTI) onboard \AstroSat, show a hint of high degree of polarization. The presence of a hint of high degree of polarization and the values of low energy spectral index ($α_{\rm pt}$) do not run over the synchrotron limit for the first two pulses, supporting the synchrotron origin in an ordered magnetic field. However, during the third pulse, $α_{\rm pt}$ exceeds the synchrotron line of death in few bins, and a thermal signature along with the synchrotron component in the time-resolved spectra is observed. Furthermore, we also report the earliest optical observations constraining afterglow polarization using the MASTER (P $<$ 1.3 \%) and the redshift measurement ($z$= 0.9386) obtained with the 10.4m GTC telescopes. The broadband afterglow can be described with a forward shock model for an ISM-like medium with a wide jet opening angle. We determine a circumburst density of $n_{0} \sim$ 7.41, kinetic energy $E_{\rm K} \sim$ 7.24 $\times 10^{54}$ erg, and radiated $γ$-ray energy $E_{\rm γ, iso} \sim$ 6.05 $\times 10^{54}$ erg, respectively.

preprint2022arXiv

Reducing the background in X-ray imaging detectors via machine learning

The sensitivity of astronomical X-ray detectors is limited by the instrumental background. The background is especially important when observing low surface brightness sources that are critical for many of the science cases targeted by future X-ray observatories, including Athena and future US-led flagship or probe-class X-ray missions. Above 2keV, the background is dominated by signals induced by cosmic rays interacting with the spacecraft and detector. We develop novel machine learning algorithms to identify events in next-generation X-ray imaging detectors and to predict the probability that an event is induced by a cosmic ray vs. an astrophysical X-ray photon, enabling enhanced filtering of the cosmic ray-induced background. We find that by learning the typical correlations between the secondary events that arise from a single primary, machine learning algorithms are able to successfully identify cosmic ray-induced background events that are missed by traditional filtering methods employed on current-generation X-ray missions, reducing the unrejected background by as much as 30 per cent.

preprint2022arXiv

X-ray speed reading: enabling fast, low noise readout for next-generation CCDs

Current, state-of-the-art CCDs are close to being able to deliver all key performance figures for future strategic X-ray missions except for the required frame rates. Our Stanford group is seeking to close this technology gap through a multi-pronged approach of microelectronics, signal processing and novel detector devices, developed in collaboration with the Massachusetts Institute of Technology (MIT) and MIT Lincoln Laboratory (MIT-LL). Here we report results from our (integrated) readout electronics development, digital signal processing and novel SiSeRO (Single electron Sensitive Read Out) device characterization.

preprint2015arXiv

Development of a Hard X-ray focal plane Compton Polarimeter: A compact polarimetric configuration with Scintillators and Si photomultipliers

X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard X-ray polarimetry is more rewarding because the sources are expected to be intrinsically highly polarized at higher energies. With the successful implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive Compton polarimeters as focal plane detectors. Such a configuration is likely to provide sensitive polarization measurements in hard X-rays with a broad energy band. We are developing a focal plane hard X-ray Compton polarimeter consisting of a plastic scintillator as active scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and 100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons scattered by the plastic scatterer are collected by a cylindrical array of 16 CsI(Tl) scintillators (5 mm x 5 mm x 150 mm) which are read by Si Photomultiplier (SiPM). Use of the new generation SiPMs ensures the compactness of the instrument which is essential for the design of focal plane detectors. The expected sensitivity of such polarimetric configuration and complete characterization of the plastic scatterer, specially at lower energies have been discussed in Chattopadhyay et al. (Exp. Astron. 35, 391-412, 2013; Astrophys. J. Suppl. 212, 12, 2014). In this paper, we characterize the CsI(Tl) absorbers coupled to SiPM. We also present the experimental results from the fully assembled configuration of the Compton polarimeter.