Source author record

Sz. Nagy

Sz. Nagy appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2012arXiv

A new mass value for 7Li

A high-accuracy mass measurement of 7Li was performed with the Smiletrap Penning trap mass spectrometer via a cyclotron frequency comparison of Li3+ and H2+. A new atomic mass value of 7Li has been determined to be 7.016,003,425,6,(45)u with a relative uncertainty of 0.63 ppb. It has uncovered a discrepancy as large as 14 sigma (1.1 micro u) deviation relative to the literature value given in the Atomic-Mass Evaluation AME 2003. The importance of the improved and revised 7Li mass value, for calibration purposes in nuclear-charge radii and atomic mass measurements of the neutron halos 9Li and 11Li, is discussed.

preprint2012arXiv

Direct mass measurements of cadmium and palladium isotopes and their double-beta transition Q-values

The Q-value of the double-electron capture in Cd-108 has been determined to be (272.04 +/- 0.55) keV in a direct measurement with the double-Penning trap mass spectrometer TRIGA-TRAP. Based on this result a resonant enhancement of the decay rate of Cd-108 is excluded. We have confirmed the double-beta transition Q-values of Cd-106 and Pd-110 recently measured with the Penning-trap mass spectrometers SHIPTRAP and ISOLTRAP, respectively. Furthermore, the atomic masses of the involved nuclides Cd-106, Cd-108, Cd-110, Pd-106, Pd-108 and Pd-110 have been directly linked to the atomic mass standard.

preprint2012arXiv

Q value and half-life of double-electron capture in Os-184

Os-184 has been excluded as a promising candidate for the search of neutrinoless double-electron capture. High-precision mass measurements with the Penning-trap mass spectrometer TRIGA-TRAP resulted in a marginal resonant enhancement with = -8.89(58) keV excess energy to the 1322.152(22) keV 0+ excited state in W-184. State-of-the-art energy density functional calculations are applied for the evaluation of the nuclear matrix elements to the excited states predicting a strong suppression due to the large deformation of mother and daughter states. The half-life of the transition in Os-184 exceeds T_{1/2} > 1.3 10^{29} years for an effective neutrino mass of 1 eV.

preprint2009arXiv

A broad-Band FT-ICR Penning TRap System for KATRIN

The KArlsruhe TRItium Neutrino experiment KATRIN aims at improving the upper limit of the mass of the electron antineutrino to about 0.2 eV (90% c.l.) by investigating the beta-decay of tritium gas molecules. The experiment is currently under construction to start first data taking in 2012. One source of systematic uncertainties in the KATRIN experiment is the formation of ion clusters when tritium decays and decay products interact with residual tritium molecules. It is essential to monitor the abundances of these clusters since they have different final state energies than tritium ions. For this purpose, a prototype of a cylindrical Penning trap has been constructed and tested at the Max-Planck-Institute for Nuclear Physics in Heidelberg, which will be installed in the KATRIN beam line. This system employs the technique of Fourier-Transform Ion-Cyclotron-Resonance in order to measure the abundances of the different stored ion species.

preprint2007arXiv

Magnetic field stabilization for high-accuracy mass measurements on exotic nuclides

The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the fluctuations by at least one order of magnitude downto dT=+/-5mK and dp=+/-50mtorr has been achieved, which corresponds to a relative frequency change of 2.7x10^{-9} and 1.5x10^{-10}, respectively. With this stabilization the frequency determination with the Penning trap only shows a linear temporal drift over several hours on the 10 ppb level due to the finite resistance of the superconducting magnet coils.