Source author record

Sylwia M. Kolenderska

Sylwia M. Kolenderska appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

Broadband-excitation-based mechanical spectroscopy of highly viscous tissue-mimicking phantoms

Standard rheometers assess mechanical properties of viscoelastic samples up to 100~Hz, which often hinders the assessment of the local-scale dynamics. We demonstrate that high-frequency analysis can be achieved by inducing broadband Rayleigh waves and monitoring their media-dependent propagation using Optical Coherence Tomography. Here, we present a new broadband wave analysis based on two-dimensional Fourier Transformation. We validated this method by comparing the mechanical parameters to monochromatic excitation data and a standard oscillatory test. Our method allows for high-frequency mechanical spectroscopy, which could be used to investigate the local-scale dynamics of different biological tissues and the influence of diseases on their microstructure.

preprint2021arXiv

Intensity correlation OCT -- a true classical equivalent of quantum OCT able to achieve up to 2-fold resolution improvement in standard OCT images

Quantum Optical Coherence Tomography (Q-OCT) uses quantum properties of light to provide several advantages over its classical counterpart, OCT: it achieves a twice better axial resolution with the same spectral bandwidth and it is immune to even orders of dispersion. Since these features are very sought-after in OCT imaging, many hardware and software techniques have been created to mimic the quantum behaviour of light and achieve these features using traditional OCT systems. The most recent, purely algorithmic scheme - an improved version of Intensity Correlation Spectral Domain OCT named ICA-SD-OCT showed even-order dispersion cancellation and reduction of artefacts. The true capabilities of this method were unfortunately severely undermined, both in terms of its relation to Q-OCT and in terms of its main performance parameters. In this work, we provide experimental demonstrations as well as numerical and analytical arguments to show that ICA-SD-OCT is a true classical equivalent of Q-OCT, more specifically its Fourier domain version, and therefore it enables a true two-fold axial resolution improvement. We believe that clarification of all the misconceptions about this very promising algorithm will highlight the great value of this method for OCT and consequently lead to its practical applications for resolution- and quality-enhanced OCT imaging.

preprint2020arXiv

Quantum Optical Coherence Tomography using two photon joint spectrum detection (JS-Q-OCT)

Quantum Optical Coherence Tomography (Q-OCT) is the non-classical counterpart of Optical Coherence Tomography (OCT) - a high-resolution 3D imaging technique based on white-light interferometry. Because Q-OCT uses a source of frequency-entangled photon pairs, not only is the axial resolution not affected by dispersion mismatch in the interferometer, but is also inherently improved by a factor of square root of two. Unfortunately, practical applications of Q-OCT are hindered by image-scrambling artefacts and slow acquisition times. Here, we present a theoretical analysis of a novel approach that is free of these problems: Q-OCT with joint spectrum detection (JS-Q-OCT). Based on a photon pair coincidence detection as in the standard Q-OCT configuration, it also discerns, each photon pair by their wavelength. We show that all the information about the internal structures of the object is encoded in the joint spectrum and can be easily retrieved through Fourier transformation. No depth scanning is required, making our technique potentially faster than standard Q-OCT. Finally, we show that the data available in the joint spectrum enables artefact removal and discuss prospective algorithms for doing so.

preprint2020arXiv

Quantum-inspired detection for Spectral Domain Optical Coherence Tomography

The intensity levels allowed by safety standards (ANSI or ICNIRP) limit the amount of light that can be used in a clinical setting to image highly scattering or absorptive tissues with Optical Coherence Tomography (OCT). To achieve high-sensitivity imaging at low intensity levels, we adapt a detection scheme -- which is used in quantum optics for providing information about spectral correlations of photons -- into a standard spectral domain OCT system. This detection scheme is based on the concept of Dispersive Fourier Transformation, where a fibre introduces a wavelength-dependent time delay measured by a single-pixel detector, usually a high-speed photoreceiver. Here, we use a fast Superconducting Single-Photon Detector (SSPD) as a single-pixel detector and obtain images of a glass stack and a slice of onion at the intensity levels of the order of 10 pW. We also provide a formula for a depth-dependent sensitivity fall-off in such a detection scheme which can be treated as a temporal equivalent of diffraction-grating-based spectrometers.