Source author record

Susana Cebrián

Susana Cebrián appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
10topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

AlphaCAMM, a Micromegas-based camera for high-sensitivity screening of alpha surface contamination

Surface contamination of $^{222}$Rn progeny from the $^{238}$U natural decay chain is one of the most difficult background contributions to measure in rare event searches experiments. In this work we propose AlphaCAMM, a gaseous chamber read with a segmented Micromegas, for the direct measurement of $^{210}$Pb surface contamination of flat samples. The detection concept exploits the readout capabilities of the Micromegas detectors for the reconstruction of $^{210}$Po alpha tracks to increase the signal-to-background ratio. We report here on the design and realization of a first 26$\times$26 cm$^2$ non-radiopure prototype, with which the detection concept is demonstrated by the use of a new algorithm for the reconstruction of alpha tracks. AlphaCAMM aims for minimum detectable $^{210}$Pb activities of $100$ nBq cm$^{-2}$ and sensitivity upper limits about $60$ nBq cm$^{-2}$ at 95\% of C.L., which requires an intrinsic background level of $5\times10^{-8}$ alphas cm$^{-2}$ s$^{-1}$. We discuss here the prospects to reach these sensitivity goals with a radiopure AlphaCAMM prototype currently under construction.

preprint2022arXiv

Snowmass2021 Cosmic Frontier White Paper: Calibrations and backgrounds for dark matter direct detection

Future dark matter direct detection experiments will reach unprecedented levels of sensitivity. Achieving this sensitivity will require more precise models of signal and background rates in future detectors. Improving the precision of signal and background modeling goes hand-in-hand with novel calibration techniques that can probe rare processes and lower threshold detector response. The goal of this white paper is to outline community needs to meet the background and calibration requirements of next-generation dark matter direct detection experiments.

preprint2021arXiv

Direct Detection of Dark Matter -- APPEC Committee Report

This Report provides an extensive review of the experimental programme of direct detection searches of particle dark matter. It focuses mostly on European efforts, both current and planned, but does it within a broader context of a worldwide activity in the field. It aims at identifying the virtues, opportunities and challenges associated with the different experimental approaches and search techniques. It presents scientific and technological synergies, both existing and emerging, with some other areas of particle physics, notably collider and neutrino programmes, and beyond. It addresses the issue of infrastructure in light of the growing needs and challenges of the different experimental searches. Finally, the Report makes a number of recommendations from the perspective of a long-term future of the field. They are introduced, along with some justification, in the opening Overview and Recommendations section and are next summarised at the end of the Report. Overall, we recommend that the direct search for dark matter particle interactions with a detector target should be given top priority in astroparticle physics, and in all particle physics, and beyond, as a positive measurement will provide the most unambiguous confirmation of the particle nature of dark matter in the Universe.

preprint2021arXiv

REST-for-Physics, a ROOT-based framework for event oriented data analysis and combined Monte Carlo response

The REST-for-Physics (Rare Event Searches Toolkit for Physics) framework is a ROOT-based solution providing the means to process and analyze experimental or Monte Carlo event data. Special care has been taken on the traceability of the code and the validation of the results produced within the framework, together with the connectivity between code and data stored registered through specific version metadata members. The framework development was originally motivated to cover the needs at Rare Event Searches experiments (experiments looking for phenomena having extremely low occurrence probability like dark matter or neutrino interactions or rare nuclear decays), and its components naturally implement tools to address the challenges in these kinds of experiments; the integration of a detector physics response, the implementation of signal processing routines, or topological algorithms for physical event identification are some examples. Despite this specialization, the framework was conceived thinking in scalability, and other event-oriented applications could benefit from the data processing routines and/or metadata description implemented in REST, being the generic framework tools completely decoupled from dedicated libraries. REST-for-Physics is a consolidated piece of software already serving the needs of different physics experiments - using gaseous Time Projection Chambers (TPCs) as detection technology - for background data analysis and detector characterization, as well as generic detector R\&D. Even though REST has been exploited mainly with gaseous TPCs, the code could be easily applied or adapted to other detection technologies. We present in this work an overview of REST-for-Physics, providing a broad perspective to the infrastructure and organization of the project as a whole. The framework and its different components will be described in the text.

preprint2020arXiv

Small scale direct dark matter search experiments

Experiments based on noble liquids and solid state cryogenic detectors have had a leading role in the direct detection of dark matter. But smaller scale projects can help to explore the new dark matter landscape with advanced, ultra-sensitive detectors based on recently developed technologies. Here, the physics case of different types of small scale dark matter experiments will be presented and many of them will be reviewed, highlighting the detection techniques and summarizing their properties, results and status.

preprint2016arXiv

PandaX-III: Searching for Neutrinoless Double Beta Decay with High Pressure $^{136}$Xe Gas Time Projection Chambers

Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China Jin Ping underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% $^{136}$Xe enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk Micromegas) will be used at both ends of the TPC for the charge readout with a cathode in the middle. Charge signals can be used to reconstruct tracks of NLDBD events and provide good energy and spatial resolution. The detector will be immersed in a large water tank to ensure $\sim$5 m of water shielding in all directions. The second phase, a ton-scale experiment, will consist of five TPCs in the same water tank, with improved energy resolution and better control over backgrounds.

preprint2015arXiv

Light Collection in the Prototypes of the ANAIS Dark Matter Project

The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS detectors consist of large NaI crystals coupled to two photomultipliers (PMTs). In this work we present Single Electron Response (SER) data for several units of the Hamamatsu R12669SEL2 PMT model extracted from normal operation data of ANAIS underground prototypes and we compare them with PMT SER characterization previously done at surface lab before coupling them to NaI crystal. Moreover, total light collection for different ANAIS prototypes has been calculated, producing an excellent average result of 15 phe/keV, which has a good impact in both energy resolution and threshold.

preprint2014arXiv

ANAIS: Status and prospects

ANAIS experiment will look for dark matter annual modulation with large mass of ultra-pure NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC), aiming to confirm the DAMA/LIBRA positive signal in a model-independent way. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra are currently taking data at the LSC. Present status of ANAIS detectors background and general performance is summarized; in particular, thanks to the high light collection efficiency prospects of lowering the threshold down to 1 keVee are reachable. Crystal radiopurity goals are fulfilled for $^{232}$Th and $^{238}$U chains and $^{40}$K activity, although higher than original goal, could be accepted; however, high $^{210}$Pb contamination out-of-equilibrium has been identified. More radiopure detectors are being built by Alpha Spectra. The ongoing high quantum efficiency PMT tests and muon veto characterization are also presented. Finally, the sensitivity of the experiment for the annual modulation in the WIMP signal, assuming the already achieved threshold and background in ANAIS-25 is shown. Further improvement should be achieved by reducing both threshold and background, as expected.

preprint2014arXiv

Analysis of the 40K contamination in NaI(Tl) crystals from different providers in the frame of the ANAIS project

NaI(Tl) large crystals are applied in the search for galactic dark matter particles through their elastic scattering off the target nuclei in the detector by measuring the scintillation signal produced. However, energies deposited in the form of nuclear recoils are small, which added to the low efficiency to convert that energy into scintillation, makes that events at or very near the energy threshold, attributed either to radioactive backgrounds or to spurious noise (non-bulk NaI(Tl) scintillation events), can compromise the sensitivity goals of such an experiment. DAMA/LIBRA experiment, using 250 kg NaI(Tl) target, reported first evidence of the presence of an annual modulation in the detection rate compatible with that expected for a dark matter signal just in the region below 6 keVee (electron equivalent energy). In the frame of the ANAIS (Annual modulation with NaI Scintillators) dark matter search project a large and long effort has been carried out in order to understand the origin of events at very low energy in large sodium iodide detectors and develop convenient filters to reject those non attributable to scintillation in the bulk NaI(Tl) crystal. 40K is probably the most relevant radioactive contaminant in the bulk for NaI(Tl) detectors because of its important contribution to the background at very low energy. ANAIS goal is to achieve levels at or below 20 ppb natural potassium. In this paper we will report on our effort to determine the 40K contamination in several NaI(Tl) crystals, by measuring in coincidence between two (or more) of them. Results obtained for the 40K content of crystals from different providers will be compared and prospects of the ANAIS dark matter search experiment will be briefly reviewed.