Source author record

Sune Darkner

Sune Darkner appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

A direct geometry processing cartilage generation method using segmented bone models from datasets with poor cartilage visibility

We present a method to generate subject-specific cartilage for the hip joint. Given bone geometry, our approach is agnostic to image modality, creates conforming interfaces, and is well suited for finite element analysis. We demonstrate our method on ten hip joints showing anatomical shape consistency and well-behaved stress patterns. Our method is fast and may assist in large-scale biomechanical population studies of the hip joint when manual segmentation or training data is not feasible.

preprint2022arXiv

A multi-patient analysis of the center of rotation trajectories using finite element models of the human mandible

Studying different types of tooth movements can help us to better understand the force systems used for tooth position correction in orthodontic treatments. This study considers a more realistic force system in tooth movement modeling across different patients and investigates the effect of the couple force direction on the position of the center of rotation (CRot). The finite-element (FE) models of human mandibles from three patients are used to investigate the position of the CRots for different patients' teeth in 3D space. The CRot is considered a single point in a 3D coordinate system and is obtained by choosing the closest point on the axis of rotation to the center of resistance (CRes). A force system, consisting of a constant load and a couple (pair of forces), is applied to each tooth, and the corresponding CRot trajectories are examined across different patients. To perform a consistent inter-patient analysis, different patients' teeth are registered to the corresponding reference teeth using an affine transformation. The selected directions and applied points of force on the reference teeth are then transformed into the registered teeth domains. The effect of the direction of the couple on the location of the CRot is also studied by rotating the couples about the three principal axes of a patient's premolar. Our results indicate that similar patterns can be obtained for the CRot positions of different patients and teeth if the same load conditions are used. Moreover, equally rotating the direction of the couple about the three principal axes results in different patterns for the CRot positions, especially in labiolingual direction. The CRot trajectories follow similar patterns in the corresponding teeth, but any changes in the direction of the force and couple cause misalignment of the CRot trajectories, seen as rotations about the long axis of the tooth.

preprint2022arXiv

Auto-segmentation of Hip Joints using MultiPlanar UNet with Transfer learning

Accurate geometry representation is essential in developing finite element models. Although generally good, deep-learning segmentation approaches with only few data have difficulties in accurately segmenting fine features, e.g., gaps and thin structures. Subsequently, segmented geometries need labor-intensive manual modifications to reach a quality where they can be used for simulation purposes. We propose a strategy that uses transfer learning to reuse datasets with poor segmentation combined with an interactive learning step where fine-tuning of the data results in anatomically accurate segmentations suitable for simulations. We use a modified MultiPlanar UNet that is pre-trained using inferior hip joint segmentation combined with a dedicated loss function to learn the gap regions and post-processing to correct tiny inaccuracies on symmetric classes due to rotational invariance. We demonstrate this robust yet conceptually simple approach applied with clinically validated results on publicly available computed tomography scans of hip joints. Code and resulting 3D models are available at: https://github.com/MICCAI2022-155/AuToSeg}

preprint2021arXiv

RootPainter3D: Interactive-machine-learning enables rapid and accurate contouring for radiotherapy

Organ-at-risk contouring is still a bottleneck in radiotherapy, with many deep learning methods falling short of promised results when evaluated on clinical data. We investigate the accuracy and time-savings resulting from the use of an interactive-machine-learning method for an organ-at-risk contouring task. We compare the method to the Eclipse contouring software and find strong agreement with manual delineations, with a dice score of 0.95. The annotations created using corrective-annotation also take less time to create as more images are annotated, resulting in substantial time savings compared to manual methods, with hearts that take 2 minutes and 2 seconds to delineate on average, after 923 images have been delineated, compared to 7 minutes and 1 seconds when delineating manually. Our experiment demonstrates that interactive-machine-learning with corrective-annotation provides a fast and accessible way for non computer-scientists to train deep-learning models to segment their own structures of interest as part of routine clinical workflows. Source code is available at \href{https://github.com/Abe404/RootPainter3D}{this HTTPS URL}.

preprint2018arXiv

A Highly Accurate Model Based Registration Method for FIB-SEM Images of Neurons

Focused Ion Beam Scanning Electron Microscope (FIB-SEM) imaging is a technique that image materials section-by-section at nano-resolution, e.g.,5 nanometer width voxels. FIB-SEM is well suited for imaging ultrastructures in cells. Unfortunately, typical setups will introduce a slight sub-pixel translation from section to section typically referred to as drift. Over multiple sections, drift compound to skew distance measures and geometric structures significantly from the pre-imaged stage. Popular correction approaches often involve standard image registration methods available in packages such as ImageJ or similar software. These methods transform the images to maximize the similarity between consecutive two-dimensional sections under some measure. We show how these standard approaches will both significantly underestimate the drift, as well as producing biased corrections as they tend to align the images such that the normal of planar biological structures are perpendicular to the sectioning direction causing poor or incorrect correction of the images. In this paper, we present a highly accurate correction method for estimating drift in isotropic electron microscope images with visible vesicles.

preprint2012arXiv

Higher-Order Momentum Distributions and Locally Affine LDDMM Registration

To achieve sparse parametrizations that allows intuitive analysis, we aim to represent deformation with a basis containing interpretable elements, and we wish to use elements that have the description capacity to represent the deformation compactly. To accomplish this, we introduce in this paper higher-order momentum distributions in the LDDMM registration framework. While the zeroth order moments previously used in LDDMM only describe local displacement, the first-order momenta that are proposed here represent a basis that allows local description of affine transformations and subsequent compact description of non-translational movement in a globally non-rigid deformation. The resulting representation contains directly interpretable information from both mathematical and modeling perspectives. We develop the mathematical construction of the registration framework with higher-order momenta, we show the implications for sparse image registration and deformation description, and we provide examples of how the parametrization enables registration with a very low number of parameters. The capacity and interpretability of the parametrization using higher-order momenta lead to natural modeling of articulated movement, and the method promises to be useful for quantifying ventricle expansion and progressing atrophy during Alzheimer's disease.

preprint2012arXiv

Locally Orderless Registration

Image registration is an important tool for medical image analysis and is used to bring images into the same reference frame by warping the coordinate field of one image, such that some similarity measure is minimized. We study similarity in image registration in the context of Locally Orderless Images (LOI), which is the natural way to study density estimates and reveals the 3 fundamental scales: the measurement scale, the intensity scale, and the integration scale. This paper has three main contributions: Firstly, we rephrase a large set of popular similarity measures into a common framework, which we refer to as Locally Orderless Registration, and which makes full use of the features of local histograms. Secondly, we extend the theoretical understanding of the local histograms. Thirdly, we use our framework to compare two state-of-the-art intensity density estimators for image registration: The Parzen Window (PW) and the Generalized Partial Volume (GPV), and we demonstrate their differences on a popular similarity measure, Normalized Mutual Information (NMI). We conclude, that complicated similarity measures such as NMI may be evaluated almost as fast as simple measures such as Sum of Squared Distances (SSD) regardless of the choice of PW and GPV. Also, GPV is an asymmetric measure, and PW is our preferred choice.