Source author record

Sumanshu Agarwal

Sumanshu Agarwal appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Application of Top-hat Transformation for Enhanced Blood Vessel Extraction

In the medical domain, different computer-aided diagnosis systems have been proposed to extract blood vessels from retinal fundus images for the clinical treatment of vascular diseases. Accurate extraction of blood vessels from the fundus images using a computer-generated method can help the clinician to produce timely and accurate reports for the patient suffering from these diseases. In this article, we integrate top-hat based preprocessing approach with fine-tuned B-COSFIRE filter to achieve more accurate segregation of blood vessel pixels from the background. The use of top-hat transformation in the preprocessing stage enhances the efficacy of the algorithm to extract blood vessels in presence of structures like fovea, exudates, haemorrhages, etc. Furthermore, to reduce the false positives, small clusters of blood vessel pixels are removed in the postprocessing stage. Further, we find that the proposed algorithm is more efficient as compared to various modern algorithms reported in the literature.

preprint2022arXiv

Parametric Scaling of Preprocessing assisted U-net Architecture for Improvised Retinal Vessel Segmentation

Extracting blood vessels from retinal fundus images plays a decisive role in diagnosing the progression in pertinent diseases. In medical image analysis, vessel extraction is a semantic binary segmentation problem, where blood vasculature needs to be extracted from the background. Here, we present an image enhancement technique based on the morphological preprocessing coupled with a scaled U-net architecture. Despite a relatively less number of trainable network parameters, the scaled version of U-net architecture provides better performance compare to other methods in the domain. We validated the proposed method on retinal fundus images from the DRIVE database. A significant improvement as compared to the other algorithms in the domain, in terms of the area under ROC curve (>0.9762) and classification accuracy (>95.47%) are evident from the results. Furthermore, the proposed method is resistant to the central vessel reflex while sensitive to detect blood vessels in the presence of background items viz. exudates, optic disc, and fovea.

preprint2015arXiv

Device Engineering of Perovskite Solar Cells to Achieve Near Ideal Efficiency

Despite the exciting recent research on perovskite based solar cells, the design space for further optimization and the practical limits of efficiency are not well known in the community. In this manuscript, we address these aspects through theoretical calculations and detailed numerical simulations. Here, we first provide the detailed balance limit efficiency in the presence of radiative and Auger recombination. Then, using coupled optical and carrier transport simulations, we identify the physical mechanisms that contribute towards bias dependent carrier collection, and hence low fill factors of current perovskite based solar cells. Curiously, we find that while Auger recombination is not a dominant factor at the detailed balance limit, it plays a significant role in device level implementations. Surprisingly, our device designs indicate that it is indeed possible to achieve efficiency and fill factor greater than 25% and 85%, respectively - even in the presence of Auger recombination.