Researcher profile

Subhash Lakshminarayana

Subhash Lakshminarayana contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Analysis of Load-Altering Attacks Against Power Grids: A Rare-Event Sampling Approach

By manipulating tens of thousands of internet-of-things (IoT) enabled high-wattage electrical appliances (e.g., WiFi-controlled air-conditioners), large-scale load-altering attacks (LAAs) can cause severe disruptions to power grid operations. In this work, we present a rare-event sampling approach to identify LAAs that lead to critical network failure events (defined by the activation of a power grid emergency response (ER)). The proposed sampler is designed to "skip" over LAA instances that are of little interest (i.e., those that do not trigger network failure), thus significantly reducing the computational complexity in identifying the impactful LAAs. We perform extensive simulations of LAAs using the Kundur two-area system (KTAS) power network while employing the rare-event sampler. The results help us identify the victim nodes from which the attacker can launch the most impactful attacks and provide insights into how the spatial distribution of LAAs triggers the activation of ERs.

preprint2022arXiv

Data-Driven Detection and Identification of IoT-Enabled Load-Altering Attacks in Power Grids

Advances in edge computing are powering the development and deployment of Internet of Things (IoT) systems to provide advanced services and resource efficiency. However, large-scale IoT-based load-altering attacks (LAAs) can seriously impact power grid operations, such as destabilising the grid's control loops. Timely detection and identification of any compromised nodes are essential to minimise the adverse effects of these attacks on power grid operations. In this work, two data-driven algorithms are proposed to detect and identify compromised nodes and the attack parameters of the LAAs. The first method, based on the Sparse Identification of Nonlinear Dynamics (SINDy) approach, adopts a sparse regression framework to identify attack parameters that best describe the observed dynamics. The second method, based on physics-informed neural networks (PINN), employs neural networks to infer the attack parameters from the measurements. Both algorithms are presented utilising edge computing for deployment over decentralised architectures. Extensive simulations are performed on IEEE 6-,14- and 39-bus systems to verify the effectiveness of the proposed methods. Numerical results confirm that the proposed algorithms outperform existing approaches, such as those based on unscented Kalman filter, support vector machines (SVM), and neural networks (NN), and effectively detect and identify locations of attack in a timely manner.

preprint2022arXiv

Load-Altering Attacks Against Power Grids under COVID-19 Low-Inertia Conditions

The COVID-19 pandemic has impacted our society by forcing shutdowns and shifting the way people interacted worldwide. In relation to the impacts on the electric grid, it created a significant decrease in energy demands across the globe. Recent studies have shown that the low demand conditions caused by COVID-19 lockdowns combined with large renewable generation have resulted in extremely low-inertia grid conditions. In this work, we examine how an attacker could exploit these {scenarios} to cause unsafe grid operating conditions by executing load-altering attacks (LAAs) targeted at compromising hundreds of thousands of IoT-connected high-wattage loads in low-inertia power systems. Our study focuses on analyzing the impact of the COVID-19 mitigation measures on U.S. regional transmission operators (RTOs), formulating a plausible and realistic least-effort LAA targeted at transmission systems with low-inertia conditions, and evaluating the probability of these large-scale LAAs. Theoretical and simulation results are presented based on the WSCC 9-bus {and IEEE 118-bus} test systems. Results demonstrate how adversaries could provoke major frequency disturbances by targeting vulnerable load buses in low-inertia systems and offer insights into how the temporal fluctuations of renewable energy sources, considering generation scheduling, impact the grid's vulnerability to LAAs.

preprint2022arXiv

Localization of Coordinated Cyber-Physical Attacks in Power Grids Using Moving Target Defense and Deep Learning

As one of the most sophisticated attacks against power grids, coordinated cyber-physical attacks (CCPAs) damage the power grid's physical infrastructure and use a simultaneous cyber attack to mask its effect. This work proposes a novel approach to detect such attacks and identify the location of the line outages (due to the physical attack). The proposed approach consists of three parts. Firstly, moving target defense (MTD) is applied to expose the physical attack by actively perturbing transmission line reactance via distributed flexible AC transmission system (D-FACTS) devices. MTD invalidates the attackers' knowledge required to mask their physical attack. Secondly, convolution neural networks (CNNs) are applied to localize line outage position from the compromised measurements. Finally, model agnostic meta-learning (MAML) is used to accelerate the training speed of CNN following the topology reconfigurations (due to MTD) and reduce the data/retraining time requirements. Simulations are carried out using IEEE test systems. The experimental results demonstrate that the proposed approach can effectively localize line outages in stealthy CCPAs.

preprint2022arXiv

Localizing Load-Altering Attacks Against Power Grids Using Deep Capsule Nets

Recent research has shown that the security of power grids can be seriously threatened by botnet-type cyber attacks that target a large number of high-wattage smart electrical appliances owned by end-users. Accurate detection and localization of such attacks is of critical importance in limiting the damage. To this end, the paper proposes a novel technique using capsule networks (CNs) tailored to the power grid security application that uses the frequency and phase angle data monitored by phasor measurement units (PMUs). With the benefit of vector output from capsules and dynamic routing agreements between them, CNs can obtain accurate detection and localization performance. To demonstrate the efficiency of the suggested technique, we compare the developed CN with benchmark data-driven methodologies, including two-dimensional convolutional neural networks (2D-CNN), one-dimensional CNN (1D-CNN), deep multi-layer perceptrons (MLP), and support vector machines (SVM). Simulations are performed on IEEE 14-, 39-, and 57-bus systems, considering various real-world issues such as PMU delays, noisy data, and missing data points. The results show that CNs significantly outperform other techniques, thus making them suitable for the aforementioned cyber security applications.

preprint2022arXiv

Mitigating Load-Altering Attacks Against Power Grids Using Cyber-Resilient Economic Dispatch

Large-scale Load-Altering Attacks (LAAs) against Internet-of-Things (IoT) enabled high-wattage electrical appliances (e.g., wifi-enabled air-conditioners, electric vehicles, etc.) pose a serious threat to power systems' security and stability. In this work, a Cyber-Resilient Economic Dispatch (CRED) framework is presented to mitigate the destabilizing effect of LAAs while minimizing the overall operational cost by dynamically optimizing the frequency droop control gains of Inverter-Based Resources (IBRs). The system frequency dynamics incorporating both LAAs and the IBR droop control are modeled. The system stability constraints are explicitly derived based on parametric sensitivities. To incorporate them into the CRED model and minimize the error of the sensitivity analysis, a recursive linearization method is further proposed. A distributionally robust approach is applied to account for the uncertainty associated with the LAA detection/parameter estimation. The overall performance of the proposed CRED model is demonstrated through simulations in a modified IEEE reliability test system.

preprint2020arXiv

Data-Driven False Data Injection Attacks Against Power Grids: A Random Matrix Approach

We address the problem of constructing false data injection (FDI) attacks that can bypass the bad data detector (BDD) of a power grid. The attacker is assumed to have access to only power flow measurement data traces (collected over a limited period of time) and no other prior knowledge about the grid. Existing related algorithms are formulated under the assumption that the attacker has access to measurements collected over a long (asymptotically infinite) time period, which may not be realistic. We show that these approaches do not perform well when the attacker has a limited number of data samples only. We design an enhanced algorithm to construct FDI attack vectors in the face of limited measurements that can nevertheless bypass the BDD with high probability. The algorithm design is guided by results from random matrix theory. Furthermore, we characterize an important trade-off between the attack's BDD-bypass probability and its sparsity, which affects the spatial extent of the attack that must be achieved. Extensive simulations using data traces collected from the MATPOWER simulator and benchmark IEEE bus systems validate our findings.