Source author record

Stephen D. Bongiorno

Stephen D. Bongiorno appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2023arXiv

Determination of X-ray pulsar geometry with IXPE polarimetry

Using observations of X-ray pulsar Her X-1 by the Imaging X-ray Polarimetry Explorer, we report on a highly significant ($>17σ$) detection of the polarization signal from an accreting neutron star. The observed degree of the linear polarization of $\sim$10\% is found to be far below theoretical expectations for this object, and stays low throughout the spin cycle of the pulsar. Both the polarization degree and the angle exhibit variability with pulse phase, which allowed us to measure the pulsar spin position angle 57(2) deg and the magnetic obliquity 12(4) deg, which is an essential step towards detailed modelling of the intrinsic emission of X-ray pulsars. Combining our results with the optical polarimetric data, we find that the spin axis of the neutron star and the angular momentum of the binary orbit are misaligned by at least $\sim$20 deg, which is a strong argument in support of the models explaining stability of the observed super-orbital variability with the precession of the neutron star.

preprint2022arXiv

Limits on X-ray Polarization at the Core of Centaurus A as Observed with the Imaging X-ray Polarimetry Explorer

We present measurements of the polarization of X-rays in the $2-8 \thinspace \mathrm{keV}$ band from the nucleus of the radio galaxy Centaurus A (Cen A), using a 100ks observation from the Imaging X-ray Polarimetry Explorer (IXPE). Nearly simultaneous observations of Cen A were also taken with the Swift, NuSTAR, and INTEGRAL observatories. No statistically significant degree of polarization is detected with IXPE. These observations have a minimum detectable polarization at $99 \%$ percent confidence (MDP$_{99}$) of $6.5 \%$ using a weighted, spectral model-independent calculation in the $2-8 \thinspace \mathrm{keV}$ band. The polarization angle $ψ$ is consequently unconstrained. Spectral fitting across three orders of magnitude in X-ray energy ($0.3-400 \thinspace \mathrm{keV}$) demonstrates that the SED of Cen A is well described by a simple power law with moderate intrinsic absorption ($N_H \sim 10^{23} \thinspace \mathrm{cm}^{-2}$) and a Fe K$α$ emission line, although a second unabsorbed power law is required to account for the observed spectrum at energies below $2 \thinspace \mathrm{keV}$. This spectrum suggests that the reprocessing material responsible for this emission line is optically thin and distant from the central black hole. Our upper limits on the X-ray polarization are consistent with the predictions of Compton scattering, although the specific seed photon population responsible for production of the X-rays cannot be identified. The low polarization degree, variability in the core emission, and the relative lack of variability in the Fe K$α$ emission line support a picture where electrons are accelerated in a region of highly disordered magnetic fields surrounding the innermost jet.

preprint2022arXiv

Simultaneous space and phase resolved X-ray polarimetry of the Crab Pulsar and Nebula

The Crab pulsar and its nebula are among the most studied astrophysical systems, and constitute one of the most promising environments where high energy processes and particle acceleration can be investigated. They are the only objects for which previous X-ray polarisation has been reported. We present here the first Imaging X-ray Polarimetry Explorer (IXPE) observation of the Crab pulsar and nebula. The total pulsar pulsed emission in the [2-8] keV energy range is unpolarised. Significant polarisation up to 15% is detected only in the core of the main peak. The nebula has a total space integrated polarised degree of 20% and polarisation angle of 145deg. The polarised maps show a large variation in the local polarisation, and regions with polarised degree up to 45-50%. The polarisation pattern suggests a predominantly toroidal magnetic field.

preprint2013arXiv

Characterization of Si Hybrid CMOS Detectors for use in the Soft X-ray Band

We report on the characterization of four Teledyne Imaging Systems HAWAII Hybrid Si CMOS detectors designed for X-ray detection. Three H1RG detectors were studied along with a specially configured H2RG. Read noise measurements were performed, with the lowest result being 7.1 e- RMS. Interpixel capacitive crosstalk (IPC) was measured for the three H1RGs and for the H2RG. The H1RGs had IPC upper limits of 4.0 - 5.5 % (up & down pixels) and 8.7 - 9.7 % (left & right pixels), indicating a clear asymmetry. Energy resolution is reported for two X-ray lines, 1.5 & 5.9 keV, at multiple temperatures between 150 - 210 K. The best resolution measured at 5.9 keV was 250 eV (4.2 %) at 150 K, with IPC contributing significantly to this measured energy distribution. The H2RG, with a unique configuration designed to decrease the capacitive coupling between ROIC pixels, had an IPC of 1.8 +/- 1.0 % indicating a dramatic improvement in IPC with no measurable asymmetry. We also measured dark current as a function of temperature for each detector. For the detector with the lowest dark current, at 150 K, we measured a dark current of 0.020 +/- 0.001 (e- sec-1 pix-1). There is also a consistent break in the fit to the dark current data for each detector. Above 180 K, all the data can be fit by the product of a power law in temperature and an exponential. Below 180 K the dark current decreases more slowly; a shallow power law or constant must be added to each fit, indicating a different form of dark current is dominant in this temperature regime. Dark current figures of merit at 293 K are estimated from the fit for each detector.

preprint2012arXiv

Characterization of an x-ray hybrid CMOS detector with low interpixel capacitive crosstalk

We present the results of x-ray measurements on a hybrid CMOS detector that uses a H2RG ROIC and a unique bonding structure. The silicon absorber array has a 36μm pixel size, and the readout array has a pitch of 18μm; but only one readout circuit line is bonded to each 36x36μm absorber pixel. This unique bonding structure gives the readout an effective pitch of 36μm. We find the increased pitch between readout bonds significantly reduces the interpixel capacitance of the CMOS detector reported by Bongiorno et al. 2010 and Kenter et al. 2005.

preprint2009arXiv

Measurements of Si Hybrid CMOS X-Ray Detector Characteristics

The development of Hybrid CMOS Detectors (HCDs) for X-Ray telescope focal planes will place them in con- tention with CCDs on future satellite missions due to their faster frame rates, flexible readout scenarios, lower power consumption, and inherent radiation hardness. CCDs have been used with great success on the current generation of X-Ray telescopes (e.g. Chandra, XMM, Suzaku, and Swift). However their bucket-brigade read-out architecture, which transfers charge across the chip with discrete component readout electronics, results in clockrate limited readout speeds that cause pileup (saturation) of bright sources and an inherent susceptibility to radiation induced displacement damage that limits mission lifetime. In contrast, HCDs read pixels with low power, on-chip multiplexer electronics in a random access fashion. Faster frame rates achieved with multi-output readout design will allow the next generation's larger effective area telescopes to observe bright sources free of pileup. Radiation damaged lattice sites effect a single pixel instead of an entire row. Random access, multi-output readout will allow for novel readout modes such as simultaneous bright-source-fast/whole-chip-slow readout. In order for HCDs to be useful as X-Ray detectors, they must show noise and energy resolution performance similar to CCDs while retaining advantages inherent to HCDs. We will report on readnoise, conversion gain, and energy resolution measurements of an X-Ray enhanced Teledyne HAWAII-1RG (H1RG) HCD and describe techniques of H1RG data reduction.