Researcher profile

Stefano Laureti

Stefano Laureti contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

A low-cost flexible instrument made of off-the-shelf components for pulsed eddy current testing: overview and application to pseudo-noise excitation

A flexible and low-cost device for eddy current non-destructive testing made of off-the-shelf components is described. The proposed system is compact and easy to operate, and it consists of a dual H-bridge stepper motor driver, a coil winded in-house on an additively manufactured support, a tunnel magnetoresistance sensor, and a data generation/acquisition module. For the latter, two different commercial devices have been used, and both setups have been then tested on a benchmark sample to detect small artificial cracks. The system can flexibly generate the square pulse or square wave with tunable duration and frequency, as well as pseudo-noise binary waveforms that are here used in combination with pulse-compression to increase the inspection sensitivity with respect to standard pulsed eddy current testing. A benchmark sample was analysed, and all the defects were correctly located, demonstrating the good detection capability of the sensor. This was achieved by assembling a very low-cost handy device, which can be further improved in portability and performances with the use of different off-the-shelf components, and that can be easily integrated with single-board PC, paving the way for future developments in this field.

preprint2021arXiv

Capacitive imaging using fused amplitude and phase information for improved defect detection

This paper introduces an improved image processing method usable in capacitive imaging applications. Standard capacitive imaging tends to prefer amplitude-based images over the use of phase due to better signal-to-noise ratios. The new approach exploits the best features of both types of information by combining them to form clearer images, hence improving both defect detection and characterization in non-destructive evaluation. The methodology is demonstrated and optimized using a benchmark sample. Additional experiments on glass fibre composite sample illustrate the advantages of the technique.

preprint2021arXiv

Quantitative Evaluation of Crack Depths on Thin Aluminum Plate using Eddy Current Pulse-Compression Thermography

Eddy current stimulated thermography is an emerging technique for non-destructive testing and evaluation of conductive materials. However, quantitative estimation of the depth of subsurface defects in metallic materials by thermography techniques remains challenging due to significant lateral thermal diffusion. This work presents the application of eddy current pulse compression thermography to detect surface and subsurface defects with various depths in an aluminum sample. Kernel Principal Component analysis and Low Rank Sparse modelling were used to enhance the defective area, and cross point feature was exploited to quantitatively evaluate the defects depth. Based on experimental results, it is shown that the crossing point feature has a monotonic relationship with surface and subsurface defects depth, and it can also indicate whether the defect is within or beyond the eddy current skin depth. In addition, the comparison study between aluminum and composites in terms of impulse response and proposed features are also presented.

preprint2020arXiv

Trapped air metamaterials for ultrasonic sub-wavelength imaging in water

Acoustic metamaterials constructed from conventional base materials can exhibit exotic phenomena such as negative refractive index, extraordinary transmission-absorption and sub-wavelength imaging. These are typically achieved by combining geometrical and resonance effects. Holey-structured acoustic metamaterials have already shown potential for sub-wavelength acoustic imaging in air, where it is relatively simple to achieve the required difference in acoustic impedance needed to create resonances within the holes. However, the use of polymers for metamaterial operation in water is difficult, due to the much lower difference in acoustic impedance between water and the many polymers used, for example, in additive manufacturing. Hence, metals are commonly used. Here we show that this can be overcome by trapping air layers so that they surround each water-filled channel, making sub-wavelength imaging in water possible. The operation of such a Trapped air design is confirmed at 200-300 kHz ultrasonic frequencies via both finite element modelling and experimental measurements in a water tank. It is also shown quantitatively that the trapped air design outperforms its metal counterpart. The results indicate a way forward for exploiting additive-manufacturing for realising acoustic metamaterials in water at ultrasonic frequencies.