Source author record

Shuoxing Wu

Shuoxing Wu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$ mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 $μ$m in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

preprint2020arXiv

A Tetramethylsilane TPC with Cherenkov light readout and 3D reconstruction

We describe the construction and calibration of a multi-channel liquid time projection chamber filled with Tetramethylsilane (TMS). Its charge readout system consists of 8 wires each in the $X$ and $Y$ directions. The chamber is also equipped with a Cherenkov light readout system consisting of a 5-inch photomultiplier tube (PMT) coupled to the liquid volume through a viewport. The energy scale of the detector is calibrated using positron-electron pairs produced by 4.4 MeV gamma rays emitted from an AmBe source, using an external trigger on the positron annihilation gammas. The external trigger is then reconfigured to tag cosmic ray muons passing through the active TMS volume, which are used to measure the stopping power in TMS and the electron lifetime in the detector. We find a most-probable energy loss from minimum ionising particles (MIPs) of $Δ_p/ds$ = (0.60$\pm$0.01) MeV/cm. We also derive an electron lifetime of 43$^{+680}_{-21}~μ$s by measuring the most-probable energy loss as a function of drift time. For both fast electron and muon signals, the PMT detects prompt Cherenkov light, demonstrating the possibility of random triggering. The room-temperature organic target medium, together with the self-triggering capabilities and long electron lifetimes reported in this work, make this an attractive technology to further explore for rare event detectors or other applications in the area of radiation measurements.