Researcher profile

Shunsaku Nagasawa

Shunsaku Nagasawa contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2025arXiv

First-principles response simulation of wide-gap CdTe-DSDs for the FOXSI solar sounding rocket experiment

We have developed a wide-gap CdTe double-sided strip detector (CdTe-DSD) for the fourth and fifth flights of the Focusing Optics X-ray Solar Imager sounding rocket experiment (FOXSI-4/FOXSI-5). This detector features a 30 um strip width and a variable gap width from 30 um to 70 um, enabling position resolution finer than the strip pitch by inducing charge sharing across adjacent strip electrodes and utilizing this shared energy information for position reconstruction. However, this wide-gap configuration introduces complex detector responses, such as charge loss in the gap regions and electric field distortion near the electrodes, requiring a more advanced modeling approach for interpreting observation results in FOXSI-4/FOXSI-5 and for further optimization of future detector design. To address these complexities, we have constructed a first-principles simulation framework to model the detector response. The simulation integrates Geant4-based Monte Carlo simulations of energy deposition, finite element calculations of electric and weighting fields using COMSOL Multiphysics, charge transport modeling incorporating trapping and diffusion, and calculation of the induced charge on the electrodes based on the Shockley-Ramo theorem. By introducing a surface conductive layer, which causes electric field distortion, the model successfully reproduces the experimentally observed charge loss on the cathode side. In addition, the model reproduces the distinct charge sharing behavior on the cathode and anode sides. These results validate the effectiveness of the model in characterizing the wide-gap CdTe-DSD.

preprint2025arXiv

Signal processing and data acquisition system for the BTO detectors onboard COSI

The energy range from a few hundred keV to a few MeV includes important probes such as nuclear gamma-rays and the 511 keV annihilation line. However, compared to X-rays and GeV/TeV gamma-rays, this range suffers from lower sensitivity by orders of magnitude. The upcoming NASA SMEX satellite mission Compton Spectrometer and Imager (COSI), scheduled for launch in 2027, is expected to break through this limitation with its Compton telescope utilizing a germanium semiconductor detector, covering the 0.2-5 MeV energy range. In addition to the main instrument, two Background and Transient Observer (BTO) detectors will be installed on COSI. The detectors are NaI(Tl) scintillators coupled with SiPMs, and they are being developed as a student collaboration project. BTO aims to 1) measure background radiation in orbit to maximize COSI&#39;s sensitivity and 2) detect GRBs and other gamma-ray transients. For this purpose, it is required to cover the lower-energy range from 30 keV to 2 MeV with < 20% FWHM energy resolution. In addition, large signals and afterglow generated by heavy ions penetrating the NaI(Tl) crystal should be appropriately handled. To address these requirements, we have developed a compact signal processing and data acquisition system comprised of two main components: an analog board and a digital board. The analog board amplifies signals from the SiPM, generates triggers, and performs AD conversion. The digital board features a Microchip SAMV71 microcontroller, and we developed the software to control the analog board, read ADC data via SPI interface, add timestamps, and buffer event data. Through this development, we achieved the required wide bandpass and an energy resolution of 10% FWHM at 662 keV with a processing time of 20 us per event. We also implemented veto signal generation for large signals using a discriminator and an onboard detection algorithm for transient events.

preprint2022arXiv

Study of Time Evolution of Thermal and Non-Thermal Emission from an M-Class Solar Flare

We conduct a wide-band X-ray spectral analysis in the energy range of 1.5-100 keV to study the time evolution of the M7.6 class flare of 2016 July 23, with the Miniature X-ray Solar Spectrometer (MinXSS) CubeSat and the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) spacecraft. With the combination of MinXSS for soft X-rays and RHESSI for hard X-rays, a non-thermal component and three-temperature multi-thermal component -- &#34;cool&#34; ($T \approx$ 3 MK), &#34;hot&#34; ($T \approx$ 15 MK), and &#34;super-hot&#34; ($T \approx$ 30 MK) -- were measured simultaneously. In addition, we successfully obtained the spectral evolution of the multi-thermal and non-thermal components with a 10 s cadence, which corresponds to the Alfvén time scale in the solar corona. We find that the emission measures of the cool and hot thermal components are drastically increasing more than hundreds of times and the super-hot thermal component is gradually appearing after the peak of the non-thermal emission. We also study the microwave spectra obtained by the Nobeyama Radio Polarimeters (NoRP), and we find that there is continuous gyro-synchrotron emission from mildly relativistic non-thermal electrons. In addition, we conducted a differential emission measure (DEM) analysis by using Atmospheric Imaging Assembly (AIA) onboard the Solar Dynamics Observatory (SDO) and determine that the DEM of cool plasma increases within the flaring loop. We find that the cool and hot plasma components are associated with chromospheric evaporation. The super-hot plasma component could be explained by the thermalization of the non-thermal electrons trapped in the flaring loop.

preprint2020arXiv

Imaging and Spectral Performance of a 60 μm Pitch CdTe Double-Sided Strip Detector

We have evaluated the performance of a fine pitch CdTe Double-sided Strip Detector (CdTe-DSD), which was originally developed for the focal plane detector of a hard X-ray telescope to observe the Sun. The detector has a thickness of 750 um and has 128 strip electrodes with a 60 um strip pitch orthogonally placed on both sides of the detector and covers an energy range 4 keV to 80 keV. The study of the depth of photon interaction and charge sharing effects are of importance in order to provide good spectroscopic and imaging performance. We study the tail structure observed in the spectra caused by charge trapping and develop a new method to reconstruct the spectra based on induced charge information from both anode and cathode strips. By applying this method, energy resolutions (FWHM) of 0.76 keV and 1.0 keV can be obtained at photon energies of 14 keV and 60 keV, respectively, if the energy difference between the anode and cathode is within 1 keV. Furthermore, the tail component at 60 keV is reduced, and the energy resolution of the 60 keV peak is improved from 2.4 keV to 1.5 keV (FWHM) if the energy difference is greater than 1 keV. In order to study the imaging performance, we constructed a simple imaging system using a 5 mm thick tungsten plate that has a pinhole with a diameter of 100 um. We utilize a Ba-133 radioisotope of 1 mm in diameter as a target source in combination with a 100 um slit made from 0.5 mm thickness tungsten. We imaged the Ba-133 source behind the 100 um slit using a 30 keV peak, with a 100 um pinhole placed at the center of the source-detector distance. By applying a charge sharing correction between strips, we have succeeded in obtaining a position resolution better than the strip pitch of 60 um.