Source author record

Shreyan Majumdar

Shreyan Majumdar appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
1topics
2close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2023arXiv

Simultaneous mapping of temperature and hydration in proton exchange membrane of fuel cells using magnetic resonance imaging

The efficiency of a proton exchange membrane (PEM) fuel cell depends on the mobility of protons in the PEM, which is determined by the hydration and temperature of the membrane. While optical techniques or neutron or x-ray scattering techniques may be used to study the inhomogeneities in hydration and temperature in PEMs, these techniques cannot provide 3 dimensional spatial resolution in measuring layered PEMs. Due to their ability to provide non-invasive 3D images, spin-lattice relaxation time (T1) and spin-spin relaxation time (T2) contrast magnetic resonance imaging (MRI) of protons in PEMs have been suggested as methods to map hydration in the fuel cells. We show that while T1 and T2 imaging may be used to map hydration in PEMs under isothermal conditions, proton T1 and T2 are also a function of temperature. For PEM fuel cells, where current densities are large and thermal gradients are expected, T1 and T2 relaxation times cannot be used for mapping hydration. The chemical shift of the mobile proton is, however, a strong function of hydration but not temperature. Therefore, chemical shift imaging (CSI) can be used to map hydration. The diffusion constant of the mobile proton, which can be determined by pulsed field gradient NMR, increases with both temperature and hydration. Therefore, CSI followed by imaging of diffusion via pulsed field gradients can be used for separate mappings of hydration and temperature in PEMs. Here, we demonstrate a 16 x 16 pixel MRI mapping of hydration and temperature in Nafion PEMs with a spatial resolution of 1 mm x 1 mm, a total scan time of 3 minutes, a temperature resolution of 6 K, and an uncertainty in hydration within 15%. The demonstrated mapping can be generalized for imaging exchange membranes of any fuel cells or flow batteries.