Researcher profile

Shaihan J. Malik

Shaihan J. Malik contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Parallel transmit PUlse design for Saturation Homogeneity (PUSH) for Magnetization Transfer imaging at 7T

Purpose: This work proposes a novel RF pulse design for parallel transmit (pTx) systems to obtain uniform saturation of semisolid magnetization for Magnetization Transfer (MT) contrast in the presence of transmit field ($B_1^+$) inhomogeneities. The semisolid magnetization is usually modeled as being purely longitudinal, with the applied $B_1^+$ field saturating but not rotating its magnetization, thus standard pTx pulse design methods do not apply. Theory and Methods: Pulse design for Saturation Homogeneity (PUSH) optimizes pTx RF pulses by considering uniformity of root-mean squared $B_1^+$, $B_1^{rms}$, which relates to the rate of semisolid saturation. Here we considered designs consisting of a small number of spatially non-selective sub-pulses optimized over either a single 2D plane or 3D. Simulations and in vivo experiments on a 7T Terra system with an 8-TX Nova head coil in 5 subjects were carried out to study the homogenization of $B_1^{rms}$ and of the MT contrast by acquiring MT ratio maps. Results: Simulations and in vivo experiments showed up to 6 and 2 times more uniform $B_1^{rms}$ compared to circular polarized (CP) mode for 2D and 3D optimizations, respectively. This translated into 4 and 1.25 times more uniform MT contrast, consistently for all subjects, where 2 sub-pulses were enough for the implementation and coil used. Conclusion: The proposed PUSH method obtains more uniform and higher MT contrast than CP mode within the same SAR budget.

preprint2022arXiv

Universal pulses for homogeneous excitation using single channel coils

Purpose: Universal Pulses (UPs) are excitation pulses that reduce the flip angle inhomogeneity in high field MRI systems without subject-specific optimization, originally developed for parallel transmit (PTX) systems at 7T. We investigated the potential benefits of UPs for single channel (SC) transmit systems at 3T, which are widely used for clinical and research imaging, and for which flip angle inhomogeneity can still be problematic. Methods: SC-UPs were designed using a spiral nonselective k-space trajectory for brain imaging at 3T using transmit field maps (B1+) and off-resonance maps (B0) acquired on two different scanner types: a 'standard' single channel transmit system and a system with a PTX body coil. The effect of training group size was investigated using data (200 subjects) from the standard system. The PTX system was used to compare SC-UPs to PTX-UPs (15 subjects). In two additional subjects, prospective imaging using SC-UP was studied. Results: Average flip angle error fell from 9.5+/-0.5% for 'default' excitation to 3.0+/-0.6% using SC-UPs trained over 50 subjects. Performance of the UPs was found to steadily improve as training group size increased, but stabilized after ~15 subjects. On the PTX-enabled system, SC-UPs again outperformed default excitation in simulations (4.8+/-0.6% error versus 10.6+/-0.8% respectively) though greater homogenization could be achieved with PTX-UPs (3.9+/-0.6%) and personalized pulses (SC-PP 3.6+/-1.0%, PTX-PP 2.9+/-0.6%). MP-RAGE imaging using SC-UP resulted in greater separation between grey and white matter signal intensities than default excitation. Conclusions: SC-UPs can improve excitation homogeneity in standard 3T systems without further calibration and could be used instead of a default excitation pulse for nonselective neuroimaging at 3T.