Researcher profile

Sergio Mazzola

Sergio Mazzola contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2024arXiv

Data-Driven Power Modeling and Monitoring via Hardware Performance Counters Tracking

In the current high-performance and embedded computing era, full-stack energy-centric design is paramount. Use cases require increasingly high performance at an affordable power budget, often under real-time constraints. Extreme heterogeneity and parallelism address these issues but greatly complicate online power consumption assessment, which is essential for dynamic hardware and software stack adaptations. We introduce a novel architecture-agnostic power modeling methodology with state-of-the-art accuracy, low overhead, and high responsiveness. Our methodology identifies the best Performance Monitoring Counters (PMCs) to model the power consumption of each hardware sub-system at each Dynamic Voltage and Frequency Scaling (DVFS) state. The individual linear models are combined into a complete model that effectively describes the power consumption of the whole system, achieving high accuracy and low overhead. Our evaluation reports an average estimation error of 7.5 % for power consumption and 1.3 % for energy. Furthermore, we propose Runmeter, an open-source, PMC-based monitoring framework integrated into the Linux kernel. Runmeter manages PMC samples collection and manipulation, efficiently evaluating our power models at runtime. With a time overhead of only 0.7 % in the worst case, Runmeter provides responsive and accurate power measurements directly in the kernel, which can be employed for actuation policies such as Dynamic Power Management (DPM) and power-aware task scheduling.