Researcher profile

Sebastian White

Sebastian White contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2020arXiv

Digitized Waveform Signal Processing for Fast Timing: An Application to SiPM Timing in the Presence of Dark Count Noise

In this paper we illustrate techniques for digitized waveform signal processing of fast timing detectors. In the example discussed here, timing analysis of SiPM signals in the presence of high Dark Count Rates, a large data set of digitized waveforms is used to develop an optimal strategy relevant to the electronics front end design.

preprint2020arXiv

Timing Performance of a Micro-Channel-Plate Photomultiplier Tube

The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the two MCP-PMTs combined is better than 10~ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial dependence is in quantitative agreement with a dedicated simulation. With this characterization, the suitability of MCP-PMTs as $\text{t}_\text{0}$ reference detectors has been validated.

preprint2016arXiv

Fast Timing for High-Rate Environments with Micromegas

The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation). We demonstrate a Micromegas based solution to reach this level of performance. The Micromegas acts as a photomultiplier coupled to a Cerenkov-radiator front window, which produces sufficient UV photons to convert the ~100 ps single-photoelectron jitter into a timing response of the order of 10-20 ps per incident charged particle. A prototype has been built in order to demonstrate this performance. The first laboratory tests with a pico-second laser have shown a time resolution of the order of 27 ps for ~50 primary photoelectrons, using a bulk Micromegas readout.

preprint2013arXiv

Experimental Challenges of the European Strategy for Particle Physics

In planning for the Phase II upgrades of CMS and ATLAS major considerations are: 1)being able to deal with degradation of tracking and calorimetry up to the radiation doses to be expected with an integrated luminosity of 3000 $fb^{-1}$ and 2)maintaining physics performance at a pileup level of ~140. Here I report on work started within the context of the CMS Forward Calorimetry Task Force and continuing in an expanded CERN RD52 R$&$D program integrating timing (i.e. measuring the time-of-arrival of physics objects) as a potential tool for pileup mitigation and ideas for Forward Calorimetry. For the past 4 years our group has focused on precision timing at the level of 10-20 picoseconds in an environment with rates of $~10^6-10^7$ Hz/$cm^2 $ as is appropriate for the future running of the LHC (HL-LHC era). A time resolution of 10-20 picoseconds is one of the few clear criteria for pileup mitigation at the LHC, since the interaction time of a bunch crossing has an rms of 170 picosec. While work on charged particle timing in other contexts (i.e. ALICE R$&$D) is starting to approach this precision, there have been essentially no technologies that can sustain performance at these rates. I will present results on a tracker we developed within the DOE Advanced Detector R$&$D program which is now meeting these requirements. I will also review some results from Calorimeter Projects developed within our group (PHENIX EMCAL and ATLAS ZDC) which achieved calorimeter timing precision< 100 picoseconds.

preprint2011arXiv

Mathematica with ROOT

We present an open-source Mathematica importer for CERN ROOT files. Taking advantage of Mathematica&#39;s import/export plug-in mechanism, the importer offers a simple, unified interface that cleanly wraps around its MathLink-based core that links the ROOT libraries with Mathematica. Among other tests for accuracy and efficiency, the importer has also been tested on a large (~5 Gbyte) file structure, D3PD, used by the ATLAS experiment for offline analysis without problems. In addition to describing the installation and usage of the importer, we discuss how the importer may be further improved and customized. A link to the package can be found at: http://library.wolfram.com/infocenter/Articles/7793/ and a related presentation is at: http://cd-docdb.fnal.gov/cgi-bin/DisplayMeeting?conferenceid=522

preprint2010arXiv

Diffraction at the LHC: a non-technical Introduction

In diffractive interactions of protons or nuclei a violent collision can occur that leaves the forward going particle completely intact -with probability determined by the structure of the proton or nucleus. At very high energies these collisions also occur with both incident particles remaining intact. This is called central exclusive production. If a new particle, such as the Higgs boson, were produced exclusively this process would give a precise measurement of its mass and test for expected properties of the Higgs. Because of its unusual features this process is also a promising discovery tool. In this paper I focus on analogous electromagnetic processes because many aspects apply to both- particularly the role of coherence. Also, topics in diffraction with nuclear beams are based on electromagnetic interactions. I also discuss two proposed measurements in ATLAS with Pb beams and with proton beams (diffractive Higgs production).

preprint2010arXiv

Neutron Production and Zero Degree Calorimeter Acceptance at LHC

We calculate cross sections for the far forward LHC detectors to be used for luminosity measurement. A simple model, based on a parametrization of available inclusive neutron data and the assumption that 2 arm rates in non-diffractive events are uncorrelated, is introduced. The calculated rates are in reasonable agreement with preliminary data from RHIC and we are now comparing with rates at 3 LHC energies.

preprint2010arXiv

The role of Spectator Fragments at an electron Ion collider

Efficient detection of spectator fragments is key to the main topics at an electron-ion collider (eIC). Any process which leads to emission of fragments or $γ$&#39;s breaks coherence in diffractive processes. Therefore this is equivalent to non-detection of rapidity gaps in pp collisions. For example, in coherent photoproduction of vector mesons their 4-momentum transfer distribution would image the &#34;gluon charge&#34; in the nucleus in the same way that Hofstadter measured its charge structure using elastic scattering of $\sim$100 MeV electrons. Whereas he could measure the $\sim$4 MeV energy loss by the electron due to excitation of nuclear energy levels (Figure 1), even the energy spread of the incident beam would prevent such an inclusive selection of quasielastic events at an eIC. The only available tool is fragment detection. Since, in our example, one finds that $\sim100$ of deexcitations go through $γ$&#39;s or 1 neutron, rarely to 2 neutron and never to protons(due to Coulomb barrier suppression), the eIC design should emphasize their detection.