Source author record

Sebastian Rosenzweig

Sebastian Rosenzweig appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Model-Based Reconstruction for Simultaneous Multi-Slice T1 Mapping using Single-Shot Inversion-Recovery Radial FLASH

Purpose: To develop a single-shot multi-slice T1 mapping method by combing simultaneous multi-slice (SMS) excitations, single-shot inversion-recovery (IR) radial fast low-angle shot (FLASH) and a nonlinear model-based reconstruction method. Methods: SMS excitations are combined with a single-shot IR radial FLASH sequence for data acquisition. A previously developed single-slice calibrationless model-based reconstruction is extended to SMS, formulating the estimation of parameter maps and coil sensitivities from all slices as a single nonlinear inverse problem. Joint-sparsity constraints are further applied to the parameter maps to improve T1 precision. Validations of the proposed method are performed for a phantom and for the human brain and liver in six healthy adult subjects. Results: Phantom results confirm good T1 accuracy and precision of the simultaneously acquired multi-slice T1 maps in comparison to single-slice references. In-vivo human brain studies demonstrate the better performance of SMS acquisitions compared to the conventional spoke-interleaved multi-slice acquisition using model-based reconstruction. Apart from good accuracy and precision, the results of six healthy subjects in both brain and abdominal studies confirm good repeatability between scan and re-scans. The proposed method can simultaneously acquire T1 maps for five slices of a human brain ($0.75 \times 0.75 \times 5$ mm$^3$) or three slices of the abdomen ($1.25 \times 1.25 \times 6$ mm$^3$) within four seconds. Conclusion: The IR SMS radial FLASH acquisition together with a non-linear model-based reconstruction enable rapid high-resolution multi-slice T1 mapping with good accuracy, precision, and repeatability.

preprint2016arXiv

Simultaneous multi-slice reconstruction by Regularized Nonlinear Inversion

Increasing imaging speed is of utmost importance in in-vivo magnetic resonance imaging (MRI). With simultaneous multi-slice (SMS) MRI we can simultaneously acquire several slices of an object, which allows for higher undersampling factors compared to single- or conventional multi-slice measurements by exploiting axial coil sensitivity information. In this thesis, we give a short introduction to the physical principles of MRI, cover the basics of a FLASH based SMS MRI sequence and perform tests to verify its accuracy: We check the fidelity of the slice distance as well as the flip angle and confirm the square-root-like signal-to-noise ratio benefit of SMS compared to conventional multi-slice experiments. A g-factor analysis is used to determine a favorable Cartesian undersampling scheme for multi-slice data. Common reconstruction strategies for SMS MRI make use of previously estimated coil sensitivities to solve a linear equation. Here, we propose a new method of SMS MRI based on Regularized Nonlinear Inversion (NLINV): SMS-NLINV. This method does not require a priori knowledge about the coil sensitivities and is attractive especially for real-time imaging where coil sensitivities may change due to motion or interactive changes to the slice position. We characterize the algorithm and present reconstructed phantom and in-vivo images.