Researcher profile

Sebastian Kempf

Sebastian Kempf contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Flux ramp modulation based hybrid microwave SQUID multiplexer

We present a hybrid microwave SQUID multiplexer that combines two frequency-division multiplexing techniques to allow multiplexing a given number of cryogenic detectors with only a fraction of frequency encoding resonators. Similar to conventional microwave SQUID multiplexing, our multiplexer relies on inductively coupling non-hysteretic, unshunted rf-SQUIDs to superconducting microwave resonators as well as applying flux ramp modulation for output signal linearization. However, instead of utilizing one resonator per SQUID, we couple multiple SQUIDs to a common readout resonator and encode the SQUID input signals in sidebands of the microwave carrier by varying the flux ramp modulation frequency for each SQUID. We prove the suitability of our approach using a prototype device and argue by means of fundamental information theory that our approach is particularly suited for reading out large cryogenic bolometer arrays.

preprint2021arXiv

Analytical model of the readout power and SQUID hysteresis parameter dependence of the resonator characteristics of microwave SQUID multiplexers

We report on the development of an analytical model describing the readout power and SQUID hysteresis parameter dependence of the resonator characteristics used for frequency encoding in microwave SQUID multiplexers. Within the context of this model, we derived the different dependencies by analyzing the Fourier components of the non-linear response of the non-hysteretic rf-SQUID. We show that our model contains the existing model as a limiting case, leading to identical analytical expressions for small readout powers. Considering the approximations we made, our model is valid for rf-SQUID hysteresis parameters $β_{\mathrm{L}} < 0.6$ which fully covers the parameter range of existing multiplexer devices. We conclude our work with an experimental verification of the model. In particular, we demonstrate a very good agreement between measured multiplexer characteristics and predictions based on our model.

preprint2020arXiv

Development of a novel calorimetry setup based on metallic paramagnetic temperature sensors

We have developed a new micro-fabricated platform for the measurement of the specific heat of low heat capacity mg-sized metallic samples, such as superconductors, down to temperatures of as low as $10\,\mathrm{mK}$. It addresses challenging aspects of setups of this kind such as the thermal contact between sample and platform, the thermometer resolution, and an addenda heat capacity exceeding that of the samples of interest (typically $\mbox{nJ/K at }20\,\mbox{mK}$). The setup allows us to use the relaxation method, where the thermal relaxation following a well defined heat pulse is monitored to extract the specific heat. The sample platform ($5 \times 5\, \mathrm{mm^2}$) includes a micro-structured paramagnetic \underline{Ag}:Er temperature sensor, which is read out by a dc-SQUID via a superconducting flux transformer. In this way, a relative temperature precision of $30\,\mathrm{nK/\sqrt{Hz}}$ can be reached, while the addenda heat capacity falls well below $0.5\,\mathrm{nJ/K}$ for $T < 300\,\mathrm{mK}$. A gold-coated mounting area ($4.4 \times 3 \, \mathrm{mm^2}$) is included to improve the thermal contact between sample and platform.

preprint2020arXiv

Specific Heat of Holmium in Gold and Silver at Low Temperatures

The specific heat of dilute alloys of holmium in gold and in silver plays a major role in the optimization of low temperature microcalorimeters with enclosed $^{163}\textrm{Ho}$, such as the ones developed for the neutrino mass experiment ECHo. We investigate alloys with atomic concentrations of $x_\textrm{Ho}=0.01\,\% - 4\,\%$ at temperatures between $10\,\textrm{mK}$ and $800\,\textrm{mK}$. Due to the large total angular momentum $J=8$ and nuclear spin $I=7/2$ of $\textrm{Ho}^{3+}$ ions, the specific heat of $\underline{\textrm{Au}}\textrm{:Ho}$ and $\underline{\textrm{Ag}}\textrm{:Ho}$ depends on the detailed interplay of various interactions, including contributions from the localized 4f electrons and nuclear contributions via hyperfine splitting. This makes it difficult to accurately determine the specific heat of these materials numerically. Instead, we measure their specific heat by using three experimental set-ups optimized for different concentration and temperature ranges. The results from measurements on six holmium alloys demonstrate that the specific heat of these materials is dominated by a large Schottky anomaly with its maximum at $T\approx 250\,\textrm{mK}$, which we attribute to hyperfine splitting and crystal field interactions. RKKY and dipole-dipole interactions between the holmium atoms cause additional, concentration-dependent effects. With regard to ECHo, we conclude that for typical operating temperatures of $T\leq 20\,\textrm{mK}$, silver holmium alloys with $x_\textrm{Ho}\gtrsim 1\,\%$ are suited best.