Source author record

Satyaki Bhattacharya

Satyaki Bhattacharya appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Performance Studies of the p-spray/p-stop implanted Si Sensors for the SiD Detector

Silicon Detector (SiD) is one of the proposed detector for future $e^+e^-$ Linear colliders, like International Linear Collider (ILC). The estimated neutron background for ILC is around 1 - 1.6 x 1010 1-MeV equivalent neutrons cm-2 year-1 for the Si micro strip sensors to be used in the innermost vertex detector. The p+n-n+ double-sided Si strip sensors are supposed to be used as position sensitive sensors for SiD. On the $n^+n^-$ side of these sensors, shorting due to electron accumulation leads to uniform spreading of signal over all the n+ strips. Hence inter-strip isolation becomes one of the major technological challenges. One of the attractive methods to achieve the inter-strip isolation is the use of uniform p-type implant on the silicon surface (p-spray). Another alternative is the use of floating p-type implants that surround the n-strips (p-stop). However, the high electric fields at the edge of the p-spray/p-stop have been shown to induce pre-breakdown micro-discharge. An optimization of the implant dose profile of the p-spray and p-stop is required to achieve good electrical isolation while ensuring satisfactory breakdown performance of the Si sensors. In the present work, we report the preliminary results of simulation study performed on the $n^+n^-$ Si sensors, equipped with p-spray and p-stops, using SILVACO tools.

preprint2015arXiv

Probing the light radion through diphotons at the Large Hadron Collider

A radion in a scenario with a warped extra dimension can be lighter than the Higgs boson, even if the Kaluza-Klein excitation modes of the graviton turn out to be in the multi-TeV region. The discovery of such a light radion would be gateway to new physics. We show how the two-photon mode of decay can enable us to probe a radion in the mass range 60 - 110 GeV. We take into account the diphoton background, including fragmentation effects, and include cuts designed to suppress the background to the maximum possible extent. Our conclusion is that, with an integrated luminosity of 3000 $\rm fb^{-1}$ or less, the next run of the Large Hadron Collider should be able to detect a radion in this mass range, with a significance of 5 standard deviations or more.