Researcher profile

Satya VVN Kothapalli

Satya VVN Kothapalli contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2020arXiv

Deep learning using a biophysical model for Robust and Accelerated Reconstruction (RoAR) of quantitative and artifact-free R2* images

Purpose: To introduce a novel deep learning method for Robust and Accelerated Reconstruction (RoAR) of quantitative and B0-inhomogeneity-corrected R2* maps from multi-gradient recalled echo (mGRE) MRI data. Methods: RoAR trains a convolutional neural network (CNN) to generate quantitative R2* maps free from field inhomogeneity artifacts by adopting a self-supervised learning strategy given (a) mGRE magnitude images, (b) the biophysical model describing mGRE signal decay, and (c) preliminary-evaluated F-function accounting for contribution of macroscopic B0 field inhomogeneities. Importantly, no ground-truth R2* images are required and F-function is only needed during RoAR training but not application. Results: We show that RoAR preserves all features of R2* maps while offering significant improvements over existing methods in computation speed (seconds vs. hours) and reduced sensitivity to noise. Even for data with SNR=5 RoAR produced R2* maps with accuracy of 22% while voxel-wise analysis accuracy was 47%. For SNR=10 the RoAR accuracy increased to 17% vs. 24% for direct voxel-wise analysis. Conclusion: RoAR is trained to recognize the macroscopic magnetic field inhomogeneities directly from the input magnitude-only mGRE data and eliminate their effect on R2* measurements. RoAR training is based on the biophysical model and does not require ground-truth R2* maps. Since RoAR utilizes signal information not just from individual voxels but also accounts for spatial patterns of the signals in the images, it reduces the sensitivity of R2* maps to the noise in the data. These features plus high computational speed provide significant benefits for the potential usage of RoAR in clinical settings.