Researcher profile

Samu Taulu

Samu Taulu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Calibration and localization of optically pumped magnetometers using electromagnetic coils

In this paper, we propose a method to estimate the position, orientation and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer and model these discreetly sampled fields using vector-spherical harmonics (VSH) functions. We then localize and calibrate a sensor by minimizing the sum of squared errors between the model signals and the sensor responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. By determining the coil currents based on the VSH models, the coil fields can approximate these low-order field components, yielding computationally simple initial estimates of the sensor parameters. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2° and 0.8%, respectively. Last, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

preprint2022arXiv

Effcient magnetometer sensor array selection for signal reconstruction and brain source localization

Magnetoencephalography (MEG) is a noninvasive method for measuring magnetic flux signals caused by brain activity using sensor arrays located on or above the scalp. A common strategy for monitoring brain activity is to place sensors on a nearly uniform grid, or sensor array, around the head. By increasing the total number of sensors, higher spatial-frequency components of brain activity can be resolved as dictated by Nyquist sampling theory. Currently, there are few principled mathematical architectures for sensor placement aside from Nyquist considerations. However, global brain activity often exhibits low-dimensional patterns of spatio-temporal dynamics. The low-dimensional global patterns can be computed from the singular value decomposition and can be leveraged to select a small number of sensors optimized for reconstructing brain signals and localizing brain sources. Moreover, a smaller number of sensors which are systematically chosen can outperform the entire sensor array when considering noisy measurements. We propose a greedy selection algorithm based upon the QR decomposition that is computationally efficient to implement for MEG. We demonstrate the performance of the sensor selection algorithm for the tasks of signal reconstruction and localization. The performance is dependent upon source localization, with shallow sources easily identified and reconstructed, and deep sources more difficult to locate. Our findings suggest that principled methods for sensor selection can improve MEG capabilities and potentially add cost savings for monitoring brain-wide activity.

preprint2022arXiv

Towards analytical calculation of the magnetic flux measured by magnetometers

This paper reviews magnetic flux signal calculations through pick-up loops using vector spherical harmonic expansion under the quasi-static approximation, and presents a near-analytical method of evaluating the flux through arbitrary parametrizable pick-up loops for each expansion degree. This is done by simplifying the surface flux integral (2D) into a line integral (1D). For the special case of tangential circular sensors, we present a fully analytical recursion calculation. We then compare commonly-used cubature approximations to our (near-)analytical forms, and show that cubature approximations suffer from increasing errors for higher spatial frequency components. This suggests the need for more accurate evaluations for increasingly sensitive sensors that are being developed, and our (near-)analytical forms themselves are a solution to this problem.