Source author record

S. T. Lin

S. T. Lin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

14works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2026arXiv

Search for Cosmic Ray Electron Boosted Dark Matter with the CDEX-10 Experiment

We present new constraints on the cosmic ray electron boosted light dark matter (CReDM) using the 205.4 kg$\cdot$day data of the CDEX-10 experiment located at the China Jinping Underground Laboratory. The cosmic ray electron spectrum and distribution in the Galaxy are generated by the $\tt GALPROP$ code package. In the calculation process of DM-electron scattering process in the Galaxy, we consider the energy-dependency of the DM-electron scattering cross section. The constraints on CReDM are set for both heavy and light mediator scenarios using the CDEX-10 dataset. The result exceeds previous Standard Halo Model (SHM) limits for DM mass lower than 0.6 MeV in heavy mediator case and corresponds to the best sensitivity among all direct detection experiments from 1 keV to 0.5 MeV in the light mediator scenario.

preprint2025arXiv

Constraints on inelastic dark matter from the CDEX-1B experiment

We present limits on spin-independent inelastic weakly interacting massive particles (WIMP)-nucleus scattering using the 737.1 kg$\cdot$day dataset from the CDEX-1B experiment. Expected nuclear recoil spectra for various inelastic WIMP masses $m_χ$ and mass splittings $δ$ are calculated under the standard halo model. An accurate background model of CDEX-1B is constructed by simulating all major background sources. The model parameters are then determined through maximum likelihood estimation and Markov chain Monte Carlo fitting. The resulting 90\% confidence level upper limits on the WIMP-nucleon cross section $σ_{\mathrm{n}}$ exclude certain DAMA/LIBRA allowed regions: the $χ^2 < 4$ regions for $δ< 30$ keV at $m_χ= 250$ GeV and the $χ^2 < 9$ region for $δ< 50$ keV at $m_χ= 500$ GeV. The method is applicable to other inelastic dark matter scenarios, and the upcoming CDEX-50 experiment is expected to improve sensitivity by four orders of magnitude.

preprint2022arXiv

Search for Neutrinoless Double-Beta Decay of $^{76}$Ge with a Natural Broad Energy Germanium Detector

A natural broad energy germanium (BEGe) detector is operated in the China Jinping Underground Laboratory (CJPL) for a feasibility study of building the next generation experiment of the neutrinoless double-beta (0{$νββ$}) decay of $^{76}$Ge. The setup of the prototype facility, characteristics of the BEGe detector, background reduction methods, and data analysis are described in this paper. A background index of 6.4$\times$10$^{-3}$ counts/(keV$\cdot$kg$\cdot$day) is achieved and 1.86 times lower than our previous result of the CDEX-1 detector. No signal is observed with an exposure of 186.4 kg$\cdot$day, thus a limit on the half life of $^{76}$Ge 0$νββ$ decay is set at T$_{1/2}^{0ν}$ $>$ 5.62$\times$10$^{22}$ yr at 90% C.L.. The limit corresponds to an effective Majorana neutrino mass in the range of 4.6 $\sim$ 10.3 eV, dependent on the nuclear matrix elements.

preprint2022arXiv

Studies of the Earth shielding effect to direct dark matter searches at the China Jinping Underground Laboratory

Dark matter direct detection experiments mostly operate at deep underground laboratories. It is necessary to consider shielding effect of the Earth, especially for dark matter particles interacting with a large cross section. We analyzed and simulated the Earth shielding effect for dark matter at the China Jinping Underground Laboratory (CJPL) with a simulation package, CJPL Earth Shielding Simulation code (CJPL\_ESS), which is applicable to other underground locations. The further constraints on the $χ$-N cross section exclusion regions are derived based on the studies with CDEX experiment data.

preprint2020arXiv

Direct Detection Constraints on Dark Photons with CDEX-10 Experiment at the China Jinping Underground Laboratory

We report constraints on the dark photon effective kinetic mixing parameter ($κ$) with data taken from two ${p}$-type point-contact germanium detectors of the CDEX-10 experiment at the China Jinping Underground Laboratory. The 90\% confidence level upper limits on $κ$ of solar dark photon from 205.4 kg-day exposure are derived, probing new parameter space with masses (${m_V}$) from 10 to 300 eV/${c^2}$ in direct detection experiments. Considering dark photon as the cosmological dark matter, limits at 90\% confidence level with ${m_V}$ from 0.1 to 4.0 keV/${c^2}$ are set from 449.6 kg-day data, with a minimum of ${\rm{κ=1.3 \times 10^{-15}}}$ at ${\rm{m_V=200\ eV/c^2}}$.

preprint2016arXiv

A Search of Low-Mass WIMPs with p-type Point Contact Germanium Detector in the CDEX-1 Experiment

The CDEX-1 experiment conducted a search of low-mass (< 10 GeV/c2) Weakly Interacting Massive Particles (WIMPs) dark matter at the China Jinping Underground Laboratory using a p-type point-contact germanium detector with a fiducial mass of 915 g at a physics analysis threshold of 475 eVee. We report the hardware set-up, detector characterization, data acquisition and analysis procedures of this experiment. No excess of unidentified events are observed after subtraction of known background. Using 335.6 kg-days of data, exclusion constraints on the WIMP-nucleon spin-independent and spin-dependent couplings are derived.

preprint2016arXiv

Characterization and Performance of Germanium Detectors with sub-keV Sensitivities for Neutrino and Dark Matter Experiments

Germanium ionization detectors with sensitivities as low as 100 eVee (electron-equivalent energy) open new windows for studies on neutrino and dark matter physics. The relevant physics subjects are summarized. The detectors have to measure physics signals whose amplitude is comparable to that of pedestal electronic noise. To fully exploit this new detector technique, various experimental issues including quenching factors, energy reconstruction and calibration, signal triggering and selection as well as evaluation of their associated efficiencies have to be attended. The efforts and results of a research program to address these challenges are presented.

preprint2016arXiv

Coherency in Neutrino-Nucleus Elastic Scattering

Neutrino-nucleus elastic scattering provides a unique laboratory to study the quantum mechanical coherency effects in electroweak interactions, towards which several experimental programs are being actively pursued. We report results of our quantitative studies on the transitions towards decoherency. A parameter ($α$) is identified to describe the degree of coherency, and its variations with incoming neutrino energy, detector threshold and target nucleus are studied. The ranges of $α$ which can be probed with realistic neutrino experiments are derived, indicating complementarity between projects with different sources and targets. Uncertainties in nuclear physics and in $α$ would constrain sensitivities in probing physics beyond the standard model. The maximum neutrino energies corresponding to $α$>0.95 are derived.

preprint2016arXiv

Measurement of the dead layer thickness in a p-type point contact germanium detector

A 994g mass p-type PCGe detector was deployed by the first phase of the China Dark matter EXperiment aiming at the direct searches of light weakly interacting massive particles. Measuring the thickness of the dead layer of a p-type germanium detector is an issue of major importance since it determines the fiducial mass of the detector. This work reports a method using an uncollimated 133Ba source to determine the dead layer thickness. The experimental design, data analysis and Monte Carlo simulation processes, as well as the statistical and systematic errors are described. An agreement between the experimental data and simulation results was achieved to derive the thickness of the dead layer of 1.02 mm.

preprint2014arXiv

Limits on light WIMPs from the CDEX-1 experiment with a p-type point-contact germanium detector at the China Jingping Underground Laboratory

We report results of a search for light Dark Matter WIMPs with CDEX-1 experiment at the China Jinping Underground Laboratory, based on 53.9 kg-days of data from a p-type point-contact germanium detector enclosed by a NaI(Tl) crystal scintillator as anti-Compton detector. The event rate and spectrum above the analysis threshold of 475 eVee are consistent with the understood background model. Part of the allowed regions for WIMP-nucleus coherent elastic scattering at WIMP mass of 6-20 GeV are probed and excluded. Independent of interaction channels, this result contradicts the interpretation that the anomalous excesses of the CoGeNT experiment are induced by Dark Matter, since identical detector techniques are used in both experiments.

preprint2014arXiv

Limits on light WIMPs with a germanium detector at 177 eVee threshold at the China Jinping Underground Laboratory

The China Dark Matter Experiment reports results on light WIMP dark matter searches at the China Jinping Underground Laboratory with a germanium detector array with a total mass of 20 g. The physics threshold achieved is 177 eVee ("ee" represents electron equivalent energy) at 50% signal efficiency. With 0.784 kg-days of data, exclusion region on spin-independent coupling with the nucleon is derived, improving over our earlier bounds at WIMP mass less than 4.6 GeV.

preprint2014arXiv

Measurement of intrinsic radioactive backgrounds from Cs-137 and U/Th chains in CsI(Tl) crystals

The inorganic CsI(Tl) crystal scintillator is a candidate served as an anti-compton detector for China Dark matter EXperiment (CDEX). Studying the intrinsic radiopurity of CsI(Tl) crystal is an issue of major importance. The timing, energy and spatial correlations, as well as the capability of pulse shape discrimination provide powerful methods for the measurement of intrinsic radiopurities. The experimental design, detector performance and event-selection algorithms are described. A total of 359*3 kg-days data from three prototypes of CsI(Tl) crystals were taken at China Jinping underground laboratory where offers a good shielding environment. The contamination levels of internal isotopes from Cs-137, Th-232 and U-238 series, as well as the upper bounds of U-235 series are reported. Identification of the whole alpha8 peaks from U/Th decay chains and derivation of those corresponding quenching factors are achieved.

preprint2013arXiv

First results on low-mass WIMP from the CDEX-1 experiment at the China Jinping underground Laboratory

The China Dark matter Experiment collaboration reports the first experimental limit on WIMP dark matter from 14.6 kg-day of data taken with a 994 g p-type point-contact germanium detector at the China Jinping underground Laboratory where the rock overburden is more than 2400 m. The energy threshold achieved was 400 eVee. According to the 14.6 kg-day live data, we placed the limit of N= 1.75 * 10^{-40} cm^{2} at 90% confidence level on the spin-independent cross-section at WIMP mass of 7 GeV before differentiating bulk signals from the surface backgrounds.

preprint2012arXiv

Constraints on Non-Commutative Physics Scale with Neutrino-Electron Scattering

Neutrino-electron scatterings ($ν- e$) are purely leptonic processes with robust Standard Model (SM) predictions. Their measurements can therefore provide constraints to physics beyond SM. Non-commutative (NC) field theories modify space-time commutation relations, and allow neutrino electromagnetic couplings at the tree level. Their contribution to neutrino-electron scattering cross-section was derived. Constraints were placed on the NC scale parameter $Λ_{NC}$ from $ν- e$ experiments with reactor and accelerator neutrinos. The most stringent limit of $Λ_{NC} > 3.3 TeV$ at 95% confidence level improves over the direct bounds from collider experiments.