Researcher profile

S. Strazzi

S. Strazzi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2024arXiv

First results on monolithic CMOS detector with internal gain

In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 $μ$m. This prototype is formed by a pixel array where each pixel has a total size of 100 $μ$m $\times$ 250 $μ$m and includes a high-speed front-end amplifier. After describing the sensor and the electronics architecture, both laboratory and in-beam measurements are reported and described. Optical characterisations performed with an IR pulsed laser setup have shown a sensor internal gain of about 2.5. With the same experimental setup, the electronic jitter was found to be between 50 ps and 150 ps, depending on the signal amplitude. Moreover, the analysis of a test beam performed at the Proton Synchrotron (PS) T10 facility of CERN with 10 GeV/c protons and pions indicated that the overall detector time resolution is in the range of 234 ps to 244 ps. Further TCAD investigations, based on the doping profile extracted from $C(V)$ measurements, confirmed the multiplication gain measured on the test devices. Finally, TCAD simulations were used to tune the future doping concentration of the gain layer implant, targeting sensors with a higher avalanche gain. This adjustment is expected to enhance the timing performance of the sensors of the future productions, in order to cope with the high event rate expected in most of the near future high-energy and high-luminosity physics experiments, where the time resolution will be essential to disentangle overlapping events and it will also be crucial for Particle IDentification (PID).

preprint2022arXiv

Beam test results of 25 $μ$m and 35 $μ$m thick FBK UFSD]{Beam test results of 25 $μ$m and 35 $μ$m thick FBK ultra fast silicon detectors

This paper presents the measurements on first very thin Ultra Fast Silicon Detectors (UFSDs) produced by Fondazione Bruno Kessler; the data have been collected in a beam test setup at the CERN PS, using beam with a momentum of 12 GeV/c. UFSDs with a nominal thickness of 25 $μ$m and 35 $μ$m and an area of 1 $\times$ 1 $\text{mm}^2$ have been considered, together with an additional HPK 50-$μ$m thick sensor, taken as reference. Their timing performances have been studied as a function of the applied voltage and gain. A time resolution of about 25 ps and of 22 ps at a voltage of 120 V and 240 V has been obtained for the 25 and 35 $μ$m thick UFSDs, respectively.

preprint2022arXiv

Direct detection of charged particles with SiPMs

The direct response of Silicon PhotoMultipliers being traversed by a MIP charged particle have been studied in a systematic way for the first time. Using beam test data, time resolution and the crosstalk probability have been measured. A characterization of the SiPM by means of a laser beam is also reported. The results obtained for different sensors indicate a measured time resolution around 40-70 ps. Although particles are expected to traverse only one SPAD per event, crosstalk measurements on different sensors indicate an unexpected higher value with respect to the one related to the sensor noise.