Source author record

S. Salvador

S. Salvador appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

OuroborosBEM: A fast multi-GPU microscopic Monte Carlo simulation for gaseous detectors and charged particle dynamics

The design of gaseous detectors for accelerator, particle and nuclear physics requires simulations relying on multi-physics aspects. In fact, these simulations deal with the dynamics of a large number of charged particles interacting in a gaseous medium immersed in the electric field generated by a more or less complex assembly of electrodes and dielectric materials. We report here on a homemade software, called OUROBOROSBEM, able to tackle the different features involved in such simulations. After solving the electrostatic problem for which a solver based on the boundary element method (BEM) has been implemented, particles are tracked and will microscopically interact with the gas medium. Dynamical effects have been included such as the electron-ion recombination process, the charging-up of the dielectric materials and other space charge effects that might alter the detector performances. These were made possible thanks to the nVidia CUDA language specifically optimised to run on Graphical Processor Units (GPUs) to minimize the computing times. Comparisons of the results obtained for parallel plate avalanche counters and GEM detectors to literature data on swarm parameters fully validate the performances of OUROBOROSBEM. Moreover, we were able to precisely reproduce the measured gains of single and double GEM detectors as a function of the applied voltage.

preprint2020arXiv

Timing performances of a Time-of-Flight detection system for the FRACAS large acceptance mass spectrometer

In this work, we report on the timing performances of the Time-Of-Flight (TOF) apparatus of the FRACAS large acceptance mass spectrometer designed to measure the fragmentation cross sections of a $^{12}$C beam in hadrontherapy. The TOF system is composed of a Parallel Plate Avalanche Counter and scintillating detectors to create so-called $Δ$E---TOF maps used in the fragment charge identification process. From tests with an alpha source and a $^{12}$C beam experiment, we measured a coincidence resolving time for the apparatus below 300 ps. Those results should lead in the final design to the identification of all the fragments produced by the interaction of $^{12}$C ions with thin targets for energies up to 400 MeV/nucleon.

preprint2014arXiv

Zero degree measurements of 12C fragmentation at 95 MeV/nucleon on thin targets

During therapeutic treatments using ions such as carbon, nuclear interactions between the incident ions and nuclei present in organic tissues may occur, leading to the attenuation of the incident beam intensity and to the production of secondary light charged particles. As the biological dose deposited in the tumor and the surrounding healthy tissues depends on the beam composition, an accurate knowledge of the fragmentation processes is thus essential. In particular, the nuclear interaction models have to be validated using experimental double differential cross sections which are still very scarce. An experiment was realized in 2011 at GANIL to obtain these cross sections for a 95 MeV/nucleon carbon beam on different thin targets for angles raging from 4 to 43° . In order to complete these data, a new experiment was performed on September 2013 at GANIL to measure the fragmentation cross section at zero degree for a 95 MeV/nucleon carbon beam on thin targets. In this work, the experimental setup will be described, the analysis method detailed and the results presented.

preprint2013arXiv

Double di ffential fragmentation cross sections measurements of 95 MeV/u 12C on thin targets for hadrontherapy

During therapeutic treatment with heavy ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, an accurate prediction on the fluences of these secondary fragments is necessary. Nowadays, a very limited set of double di ffential carbon fragmentation cross sections are being measured in the energy range used in hadrontherapy (40 to 400 MeV/u). Therefore, new measurements are performed to determine the double di ffential cross section of carbon on di erent thin targets. This work describes the experimental results of an experiment performed on May 2011 at GANIL. The double di ffential cross sections and the angular distributions of secondary fragments produced in the 12C fragmentation at 95 MeV/u on thin targets (C, CH2, Al, Al2O3, Ti and PMMA) have been measured. The experimental setup will be precisely described, the systematic error study will be explained and all the experimental data will be presented.

preprint2013arXiv

Simulation study on light ions identification methods for carbon beams from 95 to 400 MeV/A

Monte Carlo simulations have been performed in order to evaluate the efficiencies of several light ions identification techniques. The detection system was composed with layers of scintillating material to measure either the deposited energy or the time-of-flight of ions produced by nuclear reactions between 12C projectiles and a PMMA target. Well known techniques such as (DELTA) E--Range, (DELTA) E--E--ToF and (DELTA)E--E are presented and their particle identification efficiencies are compared one to another regarding the generated charge and mass of the particle to be identified. The simulations allowed to change the beam energy matching the ones proposed in an hadron therapy facility, namely from 95 to 400 MeV/A.