Source author record

S. Ritt

S. Ritt appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

14works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2024arXiv

A search for $μ^+\to e^+γ$ with the first dataset of the MEG II experiment

The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $μ^+\to e^+γ$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($μ^+\to e^+γ$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($μ^+\to e^+γ$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.

preprint2024arXiv

Operation and performance of MEG II detector

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

preprint2016arXiv

Commissioning experience and beam physics measurements at the SwissFEL Injector Test Facility

The SwissFEL Injector Test Facility operated at the Paul Scherrer Institute between 2010 and 2014, serving as a pilot plant and testbed for the development and realization of SwissFEL, the X-ray Free-Electron Laser facility under construction at the same institute. The test facility consisted of a laser-driven rf electron gun followed by an S-band booster linac, a magnetic bunch compression chicane and a diagnostic section including a transverse deflecting rf cavity. It delivered electron bunches of up to 200 pC charge and up to 250 MeV beam energy at a repetition rate of 10 Hz. The measurements performed at the test facility not only demonstrated the beam parameters required to drive the first stage of an FEL facility, but also led to significant advances in instrumentation technologies, beam characterization methods and the generation, transport and compression of ultra-low-emittance beams. We give a comprehensive overview of the commissioning experience of the principal subsystems and the beam physics measurements performed during the operation of the test facility, including the results of the test of an in-vacuum undulator prototype generating radiation in the vacuum ultraviolet and optical range.

preprint2016arXiv

Measurement of the radiative decay of polarized muons in the MEG experiment

We studied the radiative muon decay $μ^+ \to e^+ν\barνγ$ by using for the first time an almost fully polarized muon source. We identified a large sample (~13000) of these decays in a total sample of 1.8x10^14 positive muon decays collected in the MEG experiment in the years 2009--2010 and measured the branching ratio B($μ^+ \to e^+ν\barνγ$) = (6.03+-0.14(stat.)+-0.53(sys.))x10^-8 for E_e > 45 MeV and E_γ > 40 MeV, consistent with the Standard Model prediction. The precise measurement of this decay mode provides a basic tool for the timing calibration, a normalization channel, and a strong quality check of the complete MEG experiment in the search for $μ^+ \to e^+γ$ process.

preprint2016arXiv

Muon polarization in the MEG experiment: predictions and measurements

The MEG experiment makes use of one of the world's most intense low energy muon beams, in order to search for the lepton flavour violating process $μ^{+} \rightarrow {\rm e}^{+} γ$. We determined the residual beam polarization at the thin stopping target, by measuring the asymmetry of the angular distribution of Michel decay positrons as a function of energy. The initial muon beam polarization at the production is predicted to be $P_μ = -1$ by the Standard Model (SM) with massless neutrinos. We estimated our residual muon polarization to be $P_μ = -0.85 \pm 0.03 ~ {\rm (stat)} ~ { }^{+ 0.04}_{-0.05} ~ {\rm (syst)}$ at the stopping target, which is consistent with the SM predictions when the depolarizing effects occurring during the muon production, propagation and moderation in the target are taken into account. The knowledge of beam polarization is of fundamental importance in order to model the background of our ${\megsign}$ search induced by the muon radiative decay: $μ^{+} \rightarrow {\rm e}^{+} \barν_μ ν_{\rm e} γ$.

preprint2014arXiv

Novel Calibration Method for Switched Capacitor Arrays Enables Time Measurements with Sub-Picosecond Resolution

Switched capacitor arrays (SCA) ASICs are becoming more and more popular for the readout of detector signals, since the sampling frequency of typically several gigasamples per second allows excellent pile-up rejection and time measurements. They suffer however from the fact that their sampling bins are not equidistant in time, given by limitations of the chip process. In the past, this limited time measurements of optimal signals to standard deviations (σ) of about 4-25 ps in accuracy for the split pulse test, depending on the specific chip. This paper introduces a novel time calibration, which determines the true sampling speed of an SCA. Additionally, for two independently running SCA chips, the achieved time resolution improved to less than 3 ps (σ) independently from the delay for the split pulse test, when simply applying a linear interpolation. When using a more advanced analyzing technique for the split pulse test with a single SCA, this limit is pushed below 1 ps (σ) for delays up to 8 ns. Various test measurements with different boards based on the DRS4 ASIC indicate that the new calibration is stable over time but not over larger temperature variations.

preprint2013arXiv

A direct time measurements technique for the two-dimensional precision coordinate detectors based on thin-walled drift tubes

This article presents the results of a study of the longitudinal spatial resolution of 2 m long straw tubes by means of the direct timing method (DTM). The feasibility of achieving a coordinate resolution (r.m.s.) better than 2 cm over full length of the straw is demonstrated. The spatial resolution insignificantly changes when measured by detecting gammas from a Fe-55 gamma ray source or minimum ionizing particles from a Ru-106 source. The use of the same type of FEE for data taking both for measuring the drift time of ionization electrons and propagation of a signal along the anode wire allows one to construct a two-dimensional detector for precision coordinate measurements.

preprint2013arXiv

MEG Upgrade Proposal

We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ\to e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 \times 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stopping target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.

preprint2013arXiv

New constraint on the existence of the mu+-> e+ gamma decay

The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.

preprint2013arXiv

Research Proposal for an Experiment to Search for the Decay μ -> eee

We propose an experiment (Mu3e) to search for the lepton flavour violating decay mu+ -> e+e-e+. We aim for an ultimate sensitivity of one in 10^16 mu-decays, four orders of magnitude better than previous searches. This sensitivity is made possible by exploiting modern silicon pixel detectors providing high spatial resolution and hodoscopes using scintillating fibres and tiles providing precise timing information at high particle rates.

preprint2013arXiv

The MEG detector for $μ+\to e+γ$ decay search

The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.

preprint2012arXiv

Development of a plasma panel radiation detector: recent progress and key issues

A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pitch can be less than 100 micrometer) of ionizing and minimum ionizing particles. The PPS is assembled from non-reactive, intrinsically radiation-hard materials: glass substrates, metal electrodes and inert gas mixtures. We report on the PPS development program, including simulations and design and the first laboratory studies which demonstrate the usage of plasma display panels in measurements of cosmic ray muons, as well as the expansion of experimental results on the detection of betas from radioactive sources.

preprint2010arXiv

A limit for the mu -> e gamma decay from the MEG experiment

A search for the decay mu -> e gamma, performed at PSI and based on data from the initial three months of operation of the MEG experiment, yields an upper limit on the branching ratio of BR(mu -> e gamma) < 2.8 x 10**-11 (90% C.L.). This corresponds to the measurement of positrons and photons from ~ 10**14 stopped mu-decays by means of a superconducting positron spectrometer and a 900 litre liquid xenon photon detector.

preprint2003arXiv

Design, Commissioning and Performance of the PIBETA Detector at PSI

We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid angle. The calorimeter is supplemented with an active collimator/beam degrader system, an active segmented plastic target, a pair of low-mass cylindrical wire chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole detector system is housed inside a temperature-controlled lead brick enclosure which in turn is lined with cosmic muon plastic veto counters. Commissioning and calibration data were taken during two three-month beam periods in 1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We examine the timing, energy and angular detector resolution for photons, positrons and protons in the energy range of 5-150 MeV, as well as the response of the detector to cosmic muons. We illustrate the detector signatures for the assorted rare pion and muon decays and their associated backgrounds.