Researcher profile

S. Poli

S. Poli contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2015arXiv

Design and RF measurements of a 5 GHz 500 kW window for the ITER LHCD system

CEA/IRFM is conducting R\&D efforts in order to validate the critical RF components of the 5 GHz ITER LHCD system, which is expected to transmit 20 MW of RF power to the plasma. Two 5 GHz 500 kW BeO pill-box type window prototypes have been manufactured in 2012 by the PMB Company, in close collaboration with CEA/IRFM. Both windows have been validated at low power, showing good agreement between measured and modeling, with a return loss better than 32 dB and an insertion loss below 0.05 dB. This paper reports on the window RF design and the low power measurements. The high power tests up to 500kW have been carried out in March 2013 in collaboration with NFRI. Results of these tests are also reported. In the current ITER LHCD design, 20 MW Continuous Wave (CW) of Radio-Frequency power at 5 GHz are expected to be generated and transmitted to the plasma. In order to separate the vacuum vessel pressure from the cryostat waveguide pressure, forty eight 5 GHz 500kW CW windows are to be assembled on the waveguides at the equatorial port flange. For nuclear safety reasons, forty eight additional windows could be located in the cryostat section, to separate and monitor the cryostat waveguide pressure from the exterior transmission line pressure. These windows are identified as being one of the main critical components for the ITER LHCD system since first ITER LHCD studies [1] [2] [3] or more recently [4] [5] , and clearly require an important R\&D effort. In this context and even if the LHCD system is not part of the construction baseline, the CEA/IRFM is conducting a R\&D effort in order to validate a design and the performances of these RF windows. In order to begin the assessment of this need, two 5 GHz 500 kW/5 s pill-box type windows prototypes have been manufactured in 2012 by the PMB Company in close collaboration with the CEA/IRFM [6]. The section 2 of this paper reports the RF and mechanical design of a 5 GHz window. Some features of the mechanical design and the experimental RF measurements at low power are reported in section 3. High power results, made in collaboration with NFRI, are detailed in section 4. The development of CW windows is discussed in the conclusion. 2-RF AND MECHANICAL DESIGN The proposed 5 GHz RF window is based on a pill-box design [2] , i.e. a ceramic brazed in portion of a circular waveguide, connected on either side to a rectangular waveguide section. Typical design rules of thumb of such device are circular section diameter about the same size of the diagonal of the rectangular waveguide (cf. FIGURE 1). Without taking into account the ceramic, the circular section length is approximately half a guided wavelength of the circular TE 11 mode, in order for the device to act as a half-wave transformer. Once optimized, taking into account the ceramic, matching is correct only for a narrow band of frequency and is very sensitive to the device dimensions and the ceramic relative permittivity. The heat losses in the ceramic, which have to be extracted by an active water cooling, depends on the inside electric field topology and of ceramic dielectric loss (loss tangent). Undesirable modes due to parasitic resonances can be excited in the ceramic volume, raising the electric field and

preprint2015arXiv

Lower Hybrid antennas for nuclear fusion experiments

The nuclear fusion research goal is to demonstrate the feasibility of fusion power for peaceful purposes. In order to achieve the conditions similar to those expected in an electricity-generating fusion power plant, plasmas with a temperature of several hundreds of millions of degrees must be generated and sustained for long periods. For this purpose, RF antennas delivering multi-megawatts of power to magnetized confined plasma are commonly used in experimental tokamaks. In the gigahertz range of frequencies, high power phased arrays known as "Lower Hybrid" (LH) antennas are used to extend the plasma duration. This paper reviews some of the technological aspects of the LH antennas used in the Tore Supra tokamak and presents the current design of a proposed 20 MW LH system for the international experiment ITER.

preprint2012arXiv

A coherent polarimeter array for the Large Scale Polarization Explorer balloon experiment

We discuss the design and expected performance of STRIP (STRatospheric Italian Polarimeter), an array of coherent receivers designed to fly on board the LSPE (Large Scale Polarization Explorer) balloon experiment. The STRIP focal plane array comprises 49 elements in Q band and 7 elements in W-band using cryogenic HEMT low noise amplifiers and high performance waveguide components. In operation, the array will be cooled to 20 K and placed in the focal plane of a $\sim 0.6$ meter telescope providing an angular resolution of $\sim1.5$ degrees. The LSPE experiment aims at large scale, high sensitivity measurements of CMB polarization, with multi-frequency deep measurements to optimize component separation. The STRIP Q-band channel is crucial to accurately measure and remove the synchrotron polarized component, while the W-band channel, together with a bolometric channel at the same frequency, provides a crucial cross-check for systematic effects.