Researcher profile

S. Penttila

S. Penttila contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

First Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon

We report the first measurement of coherent elastic neutrino-nucleus scattering (\cevns) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer \cevns over the background-only null hypothesis with greater than $3σ$ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2 $\pm$ 0.7) $\times$10$^{-39}$ cm$^2$ -- consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the \cevns process and provides improved constraints on non-standard neutrino interactions.

preprint2020arXiv

COHERENT Collaboration data release from the first detection of coherent elastic neutrino-nucleus scattering on argon

Release of COHERENT collaboration data from the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on argon. This release corresponds with the results of "Analysis A" published in Akimov et al., arXiv:2003.10630 [nucl-ex]. Data is shared in a binned, text-based format representing both "signal" and "backgrounds" along with associated uncertainties such that the included data can be used to perform independent analyses. This document describes the contents of the data release as well as guidance on the use of the data. Included example code in C++ (ROOT) and Python show one possible use of the included data.

preprint2020arXiv

The n$^3$He Experiment: Parity Violation in Polarized Neutron Capture on $^{3}$He

Significant progress has been made to experimentally determine a complete set of the parity-violating (PV) weak-interaction amplitudes between nucleons. In this paper we describe the design, construction and operation of the n$^3$He experiment that was used to measure the PV asymmetry $A_{\mathrm{PV}}$ in the direction of proton emission in the reaction $\vec{\mathrm{n}} + {^3}\mathrm{He} \rightarrow {^3}\mathrm{H} + \mathrm{p}$, using the capture of polarized cold neutrons in an unpolarized gaseous $^3\mathrm{He}$ target. This asymmetry has was recently calculated \cite{Viviani,Viviani2}, both in the traditional style meson exchange picture, and in effective field theory (EFT), including two-pion exchange. The high precision result (published separately) obtained with the experiment described herein forms an important benchmark for hadronic PV (HPV) theory in few-body systems, where precise calculations are possible. To this day, HPV is still one of the most poorly understood aspects of the electro-weak theory. The calculations estimate the size of the asymmetry to be in the range of $(-9.4 \rightarrow 3.5)\times 10^{-8}$, depending on the framework or model. The small size of the asymmetry and the small overall goal uncertainty of the experiment of $δA_{\mathrm{PV}} \simeq 1\times10^{-8}$ places strict requirements on the experiment, especially on the design of the target-detector chamber. In this paper we describe the experimental setup and the measurement methodology as well as the detailed design of the chamber, including results of Garfield++ and Geant4 simulations that form the basis of the chamber design and analysis. We also show data from commissioning and production and define the systematic errors that the chamber contributes to the measured $A_{\mathrm{PV}}$. We give the final uncertainty on the measurement.

preprint2019arXiv

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.