Researcher profile

S. P. Beschapov

S. P. Beschapov contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2012arXiv

Results on the primary CR spectrum and composition reconstructed with the SPHERE-2 detector

First preliminary results of the balloon-borne experiment SPHERE-2 on the all-nuclei primary cosmic rays (PCR) spectrum and primary composition are presented. The primary spectrum in the energy range $10^{16}$--$5\cdot10^{17}$ eV was reconstructed using characteristics of Vavilov-Cherenkov radiation of extensive air showers (EAS), reflected from a snow surface. Several sources of systematic uncertainties of the spectrum were analysed. A method for separation of the primary nuclei' groups based on the lateral distribution function' (LDF) steepness parameter is presented. Preliminary estimate of the mean light nuclei' fraction $f_{30-150}$ at energies $3\cdot10^{16}$--$1.5\cdot10^{17}$ eV was performed and yielded $f_{30-150}$= (21$\pm$11)%.

preprint2012arXiv

Status of the SPHERE experiment

Here is presented the current state of the SPHERE-2 balloon-borne experiment. The detector is elevated up to 1 km above the snow surface and registers the reflected Vavilov-Cherenkov radiation from extensive air showers. This method has good sensitivity to the mass-composition of the primary cosmic rays due to its high resolution near the shower axis. The detector consists of a 1500 mm spherical mirror with a 109 PMT cluster in its focus. The electronics record a signal pulse profile in each PMT. In the last 2 years the detector was upgraded: time resolution of pulse registration was enhanced up to 12.5 ns, channel sensitivity was increased by a factor of 3, a new LED-based relative PMT calibration method was introduced, and new hardware and etc. was installed.