Source author record

S. N. Ivanov

S. N. Ivanov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2020arXiv

Measurement of the permanent electric dipole moment of the neutron

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.

preprint2015arXiv

A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron

We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of $d_\mathrm{n} = -0.21 \pm 1.82 \times10^{-26}$ $e$cm, which may be interpreted as a slightly revised upper limit on the magnitude of the EDM of $3.0 \times10^{-26}$ $e$cm (90% CL) or $ 3.6 \times10^{-26}$ $e$cm (95% CL). This paper is dedicated by the remaining authors to the memory of Prof. J. Michael Pendlebury.

preprint2015arXiv

Gravitational Depolarization of Ultracold Neutrons: Comparison with Data

We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency. We find excellent qualitative agreement, with gravitationally enhanced depolarization accounting for several previously unexplained features in the data.

preprint2015arXiv

Measurement of a false electric dipole moment signal from $^{199}$Hg atoms exposed to an inhomogeneous magnetic field

We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated with aligned magnetic and electric fields. This shift arises from the interplay between the inevitable magnetic field gradients and the motional magnetic field. The proportionality to electric-field strength makes it apparently similar to an electric dipole moment (EDM) signal, although unlike an EDM this effect is P- and T-conserving. We have used a neutron magnetic resonance EDM spectrometer, featuring a mercury co-magnetometer and an array of external cesium magnetometers, to measure the shift as a function of the applied magnetic field gradient. Our results are in good agreement with theoretical expectations.

preprint2014arXiv

New measurements of neutron electric dipole moment with double chamber EDM spectrometer

The article presents results on neutron electric dipole moment measurements (EDM), made by ILL reactor using PNPI experimental installation. Double chamber magnetic resonance spectrometer with prolonged holding of ultra cold neutrons has been employed. The obtained results at 90% confidence level determine the upper limit for EDM neutron quantity equal to $|d_n| < 5.5 \cdot 10^{-26}$ e$ \cdot$cm.

preprint2014arXiv

New source for ultracold neutrons at the Institut Laue-Langevin

A new intense superthermal source for ultracold neutrons (UCN) has been installed at a dedicated beam line at the Institut Laue-Langevin. Incident neutrons with a wavelength of 0.89 nm are converted to UCN in a five liter volume filled with superfluid $^4$He at a temperature of about 0.7 K. The UCN can be extracted to room temperature experiments. We present the cryogenic setup of the source, a characterization of the cold neutron beam, and UCN production measurements, where a UCN density in the production volume of at least 55 per cm$^3$ was determined.

preprint2013arXiv

Apparatus for Measurement of the Electric Dipole Moment of the Neutron using a Cohabiting Atomic-Mercury Magnetometer

A description is presented of apparatus used to carry out an experimental search for an electric dipole moment of the neutron, at the Institut Laue-Langevin (ILL), Grenoble. The experiment incorporated a cohabiting atomic-mercury magnetometer in order to reduce spurious signals from magnetic field fluctuations. The result has been published in an earlier letter; here, the methods and equipment used are discussed in detail.

preprint2010arXiv

New constraints on Lorentz invariance violation from the neutron electric dipole moment

We propose an original test of Lorentz invariance in the interaction between a particle spin and an electromagnetic field and report on a first measurement using ultracold neutrons. We used a high sensitivity neutron electric dipole moment (nEDM) spectrometer and searched for a direction dependence of a nEDM signal leading to a modulation of its magnitude at periods of 12 and 24 hours. We constrain such a modulation to $d_{12} < 15 \times 10^{-25} \ e\,{\rm cm}$ and $d_{24} < 10 \times 10^{-25} \ e\,{\rm cm}$ at 95~\% C.L. The result translates into a limit on the energy scale for this type of Lorentz violation effect at the level of ${\cal E}_{LV} > 10^{10}$~GeV.

preprint2009arXiv

Search for macroscopic CP violating forces using a neutron EDM spectrometer

The search for CP violating forces between nucleons in the so-called axion window of force ranges lam between 2x10^-5 m and 0.02 m is interesting because only little experimental information is available there. Axion-like particles would induce a pseudo-magnetic field for neutrons close to bulk matter. A laboratory search investigates neutron spin precession close to a heavy mirror using ultracold neutrons in a magnetic resonance spectrometer. From the absence of a shift of the magnetic resonance we established new constraints on the coupling strength of axion-like particles in terms of the product gs x gp of scalar and pseudo-scalar dimensionless constants, as a function of the force range lam, gs x gp x lam^2 <= 2x10-21 [cm^2] (C.L.95%) for 10^-4 cm < lam < 1 cm. For 0.1 cm < lam < 1 cm previous limits are improved by 4 to 5 orders of magnitude.