Source author record

S. Lucidi

S. Lucidi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

A simulation-based optimization approach for the calibration of a discrete event simulation model of an emergency department

Accurate modeling of the patient flow within an Emergency Department (ED) is required by all studies dealing with the increasing and well-known problem of overcrowding. Since Discrete Event Simulation (DES) models are often adopted with the aim of assessing solutions for reducing the impact of this worldwide phenomenon, an accurate estimation of the service time of the ED processes is necessary to guarantee the reliability of the results. However, simulation models concerning EDs are frequently affected by data quality problems, thus requiring a proper estimation of the missing parameters. In this paper, a simulation-based optimization approach is used to estimate the incomplete data in the patient flow within an ED by adopting a model calibration procedure. The objective function of the resulting minimization problem represents the deviation between simulation output and real data, while the constraints ensure that the response of the simulation is sufficiently accurate according to the precision required. Data from a real case study related to a big ED in Italy is used to test the effectiveness of the proposed approach. The experimental results show that the model calibration allows recovering the missing parameters, thus leading to an accurate DES model.

preprint2021arXiv

Determining the optimal piecewise constant approximation for the Nonhomogeneous Poisson Process rate of Emergency Department patient arrivals

Modeling the arrival process to an Emergency Department (ED) is the first step of all studies dealing with the patient flow within the ED. Many of them focus on the increasing phenomenon of ED overcrowding, which is afflicting hospitals all over the world. Since Discrete Event Simulation models are often adopted with the aim to assess solutions for reducing the impact of this problem, proper nonstationary processes are taken into account to reproduce time-dependent arrivals. Accordingly, an accurate estimation of the unknown arrival rate is required to guarantee the reliability of the results. In this work, an integer nonlinear black-box optimization problem is solved to determine the best piecewise constant approximation of the time-varying arrival rate function, by finding the optimal partition of the 24 hours into a suitable number of non equally spaced intervals. The black-box constraints of the optimization problem make the feasible solutions satisfy proper statistical hypotheses; these ensure the validity of the nonhomogeneous Poisson assumption about the arrival process, commonly adopted in the literature, and prevent mixing overdispersed data for model estimation. The cost function includes a fit error term for the solution accuracy and a penalty term to select an adequate degree of regularity of the optimal solution. To show the effectiveness of this methodology, real data from one of the largest Italian hospital EDs are used.

preprint2012arXiv

Active Radiation Shield for Space Exploration Missions (ARSSEM)

One of the major issues to be solved is the protection from the effects of ionizing radiation. Exploration mission, lasting two to three years in space, represents a very significant step from the point of view of radiation protection: both the duration (up to 5 times) and the intensity (up to 5 times) of the exposure to radiation are increased at the same time with respect to mission on the ISS reaching and sometime exceeding professional career limits. In this ARSSEM report, after reviewing the physics basis of the issue of radiation protection in space, we present results based for the first time on full physics simulation to understand the interplay among the the various factors determining the dose absorbed by the astronauts during a long duration mission: radiation composition and energy spectrum, 3D particle propagation through the magnetic field, secondary production on the spacecraft structural materia, dose sensitivity of the various parts of the human body. As first application of this approach, we use this analysis to study a new magnetic configuration based on Double Helix coil and exhibiting a number of interesting features which are suited to active shield application. The study also proposes a technology R&D roadmap for active radiation shield development which would match ESA decadal development strategy for human exploration of space.