Source author record

S. L. O'Dell

S. L. O'Dell appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Accretion geometry of the neutron star low mass X-ray binary Cyg X-2 from X-ray polarization measurements

We report spectro-polarimetric results of an observational campaign of the bright neutron star low-mass X-ray binary Cyg X-2 simultaneously observed by IXPE, NICER and INTEGRAL. Consistently with previous results, the broad-band spectrum is characterized by a lower-energy component, attributed to the accretion disc with $kT_{\rm in} \approx$ 1 keV, plus unsaturated Comptonization in thermal plasma with temperature $kT_{\rm e} = 3$ keV and optical depth $τ\approx 4$, assuming a slab geometry. We measure the polarization degree in the 2-8 keV band $P=1.8 \pm 0.3$ per cent and polarization angle $ϕ= 140^{\circ} \pm 4^{\circ}$, consistent with the previous X-ray polarimetric measurements by OSO-8 as well as with the direction of the radio jet which was earlier observed from the source. While polarization of the disc spectral component is poorly constrained with the IXPE data, the Comptonized emission has a polarization degree $P =4.0 \pm 0.7$ per cent and a polarization angle aligned with the radio jet. Our results strongly favour a spreading layer at the neutron star surface as the main source of the polarization signal. However, we cannot exclude a significant contribution from reflection off the accretion disc, as indicated by the presence of the iron fluorescence line.

preprint2015arXiv

Characterization of the Inner Knot of the Crab: The Site of the Gamma-ray Flares?

One of the most intriguing results from the gamma-ray instruments in orbit has been the detection of powerful flares from the Crab Nebula. These flares challenge our understanding of pulsar wind nebulae and models for particle acceleration. We report on the portion of a multiwavelength campaign using Keck, HST, and Chandra concentrating on a small emitting region, the Crab's inner knot, located a fraction of an arcsecond from the pulsar. We find that the knot's radial size, tangential size, peak flux, and the ratio of the flux to that of the pulsar are correlated with the projected distance of the knot from the pulsar. A new approach, using singular value decomposition for analyzing time series of images, was introduced yielding results consistent with the more traditional methods while some uncertainties were substantially reduced. We exploit the characterization of the knot to discuss constraints on standard shock-model parameters that may be inferred from our observations assuming the inner knot lies near to the shocked surface. These include inferences as to wind magnetization, shock shape parameters such as incident angle and poloidal radius of curvature, as well as the IR/optical emitting particle enthalpy fraction. We find that while the standard shock model gives good agreement with observation in many respects, there remain two puzzles: (a) The observed angular size of the knot relative to the pulsar--knot separation is much smaller than expected; (b) The variable, yet high degree of polarization reported is difficult to reconcile with a highly relativistic downstream flow.

preprint2012arXiv

Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor II

The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray Observatory. CCDs are vulnerable to radiation damage, particularly by soft protons in the radiation belts and solar storms. The Chandra team has implemented procedures to protect ACIS during high-radiation events including autonomous protection triggered by an on-board radiation monitor. Elevated temperatures have reduced the effectiveness of the on-board monitor. The ACIS team has developed an algorithm which uses data from the CCDs themselves to detect periods of high radiation and a flight software patch to apply this algorithm is currently active on-board the instrument. In this paper, we explore the ACIS response to particle radiation through comparisons to a number of external measures of the radiation environment. We hope to better understand the efficiency of the algorithm as a function of the flux and spectrum of the particles and the time-profile of the radiation event.

preprint2010arXiv

High-resolution x-ray telescopes

High-energy astrophysics is a relatively young scientific field, made possible by space-borne telescopes. During the half-century history of x-ray astronomy, the sensitivity of focusing x-ray telescopes-through finer angular resolution and increased effective area-has improved by a factor of a 100 million. This technological advance has enabled numerous exciting discoveries and increasingly detailed study of the high-energy universe-including accreting (stellar-mass and super-massive) black holes, accreting and isolated neutron stars, pulsar-wind nebulae, shocked plasma in supernova remnants, and hot thermal plasma in clusters of galaxies. As the largest structures in the universe, galaxy clusters constitute a unique laboratory for measuring the gravitational effects of dark matter and of dark energy. Here, we review the history of high-resolution x-ray telescopes and highlight some of the scientific results enabled by these telescopes. Next, we describe the planned next-generation x-ray-astronomy facility-the International X-ray Observatory (IXO). We conclude with an overview of a concept for the next next-generation facility-Generation X. The scientific objectives of such a mission will require very large areas (about 10000 m2) of highly-nested lightweight grazing-incidence mirrors with exceptional (about 0.1-arcsecond) angular resolution. Achieving this angular resolution with lightweight mirrors will likely require on-orbit adjustment of alignment and figure.

preprint2010arXiv

On Calibrations using the Crab Nebula and Models of the Nebular X-ray Emission

Motivated by a paper (Kirsch et al. 2005) on possible use of the Crab Nebula as a standard candle for calibrating X-ray response functions, we examine consequences of intrinsic departures from a single (absorbed) power law upon such calibrations. We limit our analyses to three more modern X-ray instruments-the ROSAT/PSPC, the RXTE/PCA, and the XMM-Newton/EPIC-pn (burst mode). The results indicate a need to refine two of the three response functions studied. We are also able to distinguish between two current theoretical models for the system spectrum.

preprint2010arXiv

Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor

The Advanced CCD Imaging Spectrometer (ACIS) is one of two focal-plane instruments on the Chandra X-ray Observatory. During initial radiation-belt passes, the exposed ACIS suffered significant radiation damage from trapped soft protons scattering off the x-ray telescope's mirrors. The primary effect of this damage was to increase the charge-transfer inefficiency (CTI) of the ACIS 8 front-illuminated CCDs. Subsequently, the Chandra team implemented procedures to remove the ACIS from the telescope's focus during high-radiation events: planned protection during radiation-belt transits; autonomous protection triggered by an on-board radiation monitor; and manual intervention based upon assessment of space-weather conditions. However, as Chandra's multilayer insulation ages, elevated temperatures have reduced the effectiveness of the on-board radiation monitor for autonomous protection. Here we investigate using the ACIS CCDs themselves as a radiation monitor. We explore the 10-year database to evaluate the CCDs' response to particle radiation and to compare this response with other radiation data and environment models.

preprint2000arXiv

Chandra X-Ray Observatory (CXO):Overview

The Chandra X-Ray Observatory (CXO), the x-ray component of NASA's Great Observatories, was launched early in the morning of 1999, July 23 by the Space Shuttle Columbia. The Shuttle launch was only the first step in placing the observatory in orbit. After release from the cargo bay, the Inertial Upper Stage performed two firings, and separated from the observatory as planned. Finally, after five firings of Chandra's own Integral Propulsion System--- the last of which took place 15 days after launch--- the observatory was placed in its highly elliptical orbit of 140,000 km apogee and 10,000 km perigee. After activation, the first x-rays focussed by the telescope were observed on 1999, August 12. Beginning with these initial observations one could see that the telescope had survived the launch environment and was operating as expected. The month following the opening of the sunshade door was spent adjusting the focus for each set of instrument configurations, determining the optical axis, calibrating the star camera, establishing the relative response functions, determining energy scales, and taking a series of "publicity" images. Each observation proved to be far more revealing than was expected. Finally, and despite an initial surprise and setback due to the discovery that the Chandra x-ray telescope was far more efficient for concentrating low-energy protons than had been anticipated, the observatory is performing well and is returning superb scientific data. Together with other space observatories, most notably the recently activated XMM-Newton, it is clear that we are entering a new era of discovery in high-energy astrophysics.

preprint2000arXiv

Measurements with the Chandra X-Ray Observatory's flight contamination monitor

NASA's Chandra X-ray Observatory includes a Flight Contamination Monitor (FCM), a system of 16 radioactive calibration sources mounted to the inside of the Observatory's forward contamination cover. The purpose of the FCM is to verify the ground-to-orbit transfer of the Chandra flux scale, through comparison of data acquired during the ground calibration with those obtained in orbit, immediately prior to opening the Observatory's sun-shade door. Here we report results of these measurements, which place limits on the change in mirror--detector system response and, hence, on any accumulation of molecular contamination on the mirrors' iridium-coated surfaces.