Researcher profile

R. F. Elsner

R. F. Elsner contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2011arXiv

Transient Extremely Soft X-ray Emission from the Unusually Bright CV in the Globular Cluster M3: a New CV X-ray Luminosity Record?

We observed the accreting white dwarf 1E1339.8+2837 (1E1339) in the globular cluster M3 in Nov. 2003, May 2004 and Jan. 2005, using the Chandra ACIS-S detector. The source was observed in 1992 to possess traits of a supersoft X-ray source (SSS), with a 0.1-2.4 keV luminosity as large as 2x10^{35} erg/s, after which time the source's luminosity fell by roughly two orders of magnitude, adopting a hard X-ray spectrum more typical of CVs. Our observations confirm 1E1339's hard CV-like spectrum, with photon index Gamma=1.3+-0.2. We found 1E1339 to be highly variable, with a 0.5-10 keV luminosity ranging from 1.4+-0.3x10^{34} erg/s to 8.5+4.9-4.6x10^{32} erg/s, with 1E1339's maximum luminosity being perhaps the highest yet recorded for hard X-ray emission onto a white dwarf. In Jan. 2005, 1E1339 displayed substantial low-energy emission below 0.3 keV. Although current Chandra responses cannot properly model this emission, its bolometric luminosity appears comparable to or greater than that of the hard spectral component. This raises the possibility that the supersoft X-ray emission seen from 1E1339 in 1992 may have shifted to the far-UV.

preprint2010arXiv

High-resolution x-ray telescopes

High-energy astrophysics is a relatively young scientific field, made possible by space-borne telescopes. During the half-century history of x-ray astronomy, the sensitivity of focusing x-ray telescopes-through finer angular resolution and increased effective area-has improved by a factor of a 100 million. This technological advance has enabled numerous exciting discoveries and increasingly detailed study of the high-energy universe-including accreting (stellar-mass and super-massive) black holes, accreting and isolated neutron stars, pulsar-wind nebulae, shocked plasma in supernova remnants, and hot thermal plasma in clusters of galaxies. As the largest structures in the universe, galaxy clusters constitute a unique laboratory for measuring the gravitational effects of dark matter and of dark energy. Here, we review the history of high-resolution x-ray telescopes and highlight some of the scientific results enabled by these telescopes. Next, we describe the planned next-generation x-ray-astronomy facility-the International X-ray Observatory (IXO). We conclude with an overview of a concept for the next next-generation facility-Generation X. The scientific objectives of such a mission will require very large areas (about 10000 m2) of highly-nested lightweight grazing-incidence mirrors with exceptional (about 0.1-arcsecond) angular resolution. Achieving this angular resolution with lightweight mirrors will likely require on-orbit adjustment of alignment and figure.

preprint2010arXiv

On Calibrations using the Crab Nebula and Models of the Nebular X-ray Emission

Motivated by a paper (Kirsch et al. 2005) on possible use of the Crab Nebula as a standard candle for calibrating X-ray response functions, we examine consequences of intrinsic departures from a single (absorbed) power law upon such calibrations. We limit our analyses to three more modern X-ray instruments-the ROSAT/PSPC, the RXTE/PCA, and the XMM-Newton/EPIC-pn (burst mode). The results indicate a need to refine two of the three response functions studied. We are also able to distinguish between two current theoretical models for the system spectrum.

preprint2009arXiv

Study of HST counterparts to Chandra X-ray sources in the Globular Cluster M71

We report on archival Hubble Space Telescope (HST) observations of the globular cluster M71 (NGC 6838). These observations, covering the core of the globular cluster, were performed by the Advanced Camera for Surveys (ACS) and the Wide Field Planetary Camera 2 (WFPC2). Inside the half-mass radius (r_h = 1.65') of M71, we find 33 candidate optical counterparts to 25 out of 29 Chandra X-ray sources while outside the half-mass radius, 6 possible optical counterparts to 4 X-ray sources are found. Based on the X-ray and optical properties of the identifications, we find 1 certain and 7 candidate cataclysmic variables (CVs). We also classify 2 and 12 X-ray sources as certain and potential chromospherically active binaries (ABs), respectively. The only star in the error circle of the known millisecond pulsar (MSP) is inconsistent with being the optical counterpart. The number of X-ray faint sources with L_x>4x10^{30} ergs/s (0.5-6.0 keV) found in M71 is higher than extrapolations from other clusters on the basis of either collision frequency or mass. Since the core density of M71 is relatively low, we suggest that those CVs and ABs are primordial in origin.

preprint2009arXiv

X-rays from Saturn: A study with XMM-Newton and Chandra over the years 2002-05

We present the results of the two most recent (2005) XMM-Newton observations of Saturn together with the re-analysis of an earlier (2002) observation from the XMM-Newton archive and of three Chandra observations in 2003 and 2004. While the XMM-Newton telescope resolution does not enable us to resolve spatially the contributions of the planet's disk and rings to the X-ray flux, we can estimate their strengths and their evolution over the years from spectral analysis, and compare them with those observed with Chandra. The spectrum of the X-ray emission is well fitted by an optically thin coronal model with an average temperature of 0.5 keV. The addition of a fluorescent oxygen emission line at ~0.53 keV improves the fits significantly. In accordance with earlier reports, we interpret the coronal component as emission from the planetary disk, produced by the scattering of solar X-rays in Saturn's upper atmosphere, and the line as originating from the Saturnian rings. The strength of the disk X-ray emission is seen to decrease over the period 2002 - 2005, following the decay of solar activity towards the current minimum in the solar cycle. By comparing the relative fluxes of the disk X-ray emission and the oxygen line, we suggest that the line strength does not vary over the years in the same fashion as the disk flux. We consider possible alternatives for the origin of the line. The connection between solar activity and the strength of Saturn's disk X-ray emission is investigated and compared with that of Jupiter. We also discuss the apparent lack of X-ray aurorae on Saturn and conclude that they are likely to lie below the sensitivity threshold of current Earth-bound observatories. A similar comparison for Uranus and Neptune leads to the same disappointing conclusion.

preprint2006arXiv

A study of Jupiter's aurorae with XMM-Newton

We present a detailed analysis of Jupiter's X-ray (0.2-10 keV) auroral emissions as observed by XMM-Newton in Nov. 2003 and compare it with that of an Apr. 2003 observation. We discover the existence of an electron bremsstrahlung component in the aurorae, which accounts for essentially all the X-ray flux above 2 keV: its presence had been predicted but never detected for lack of sensitivity of previous X-ray missions. This bremsstrahlung component varied significantly in strength and spectral shape over the 3.5 days covered by the Nov. 2003 observation, displaying substantial hardening of the spectrum with increasing flux. This variability may be linked to the strong solar activity taking place at the time, and may be induced by changes in the acceleration mechanisms inside Jupiter's magnetosphere. As in Apr. 2003, the auroral spectra below 2 keV are best fitted by a superposition of line emission most likely originating from ion charge exchange, with OVII playing the dominant role. We still cannot resolve conclusively the ion species responsible for the lowest energy lines (around 0.3 keV), so the question of the origin of the ions (magnetospheric or solar wind) is still open. It is conceivable that both scenarios play a role in what is certainly a very complex planetary structure. High resolution spectra of the whole planet obtained with the XMM-Newton RGS in the range 0.5-1 keV clearly separate emission lines (mostly of Fe) originating at low latitudes on Jupiter from the auroral lines due to O. These are shown to possess very broad wings which imply velocities of ~5000 km/s. Such speeds are consistent with the energies at which precipitating and charge exchanging O ions are expected to be accelerated in Jupiter's magnetosphere. Overall we find good agreement between our measurements and the predictions of recent models.

preprint2000arXiv

Measurements with the Chandra X-Ray Observatory's flight contamination monitor

NASA's Chandra X-ray Observatory includes a Flight Contamination Monitor (FCM), a system of 16 radioactive calibration sources mounted to the inside of the Observatory's forward contamination cover. The purpose of the FCM is to verify the ground-to-orbit transfer of the Chandra flux scale, through comparison of data acquired during the ground calibration with those obtained in orbit, immediately prior to opening the Observatory's sun-shade door. Here we report results of these measurements, which place limits on the change in mirror--detector system response and, hence, on any accumulation of molecular contamination on the mirrors' iridium-coated surfaces.