Researcher profile

S. Kraft

S. Kraft contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2012arXiv

Double-beta decay of $^{130}$Te to the first 0$^{+}$ excited state of $^{130}$Xe with CUORICINO

The CUORICINO experiment was an array of 62 TeO$_{2}$ single-crystal bolometers with a total $^{130}$Te mass of $11.3\,$kg. The experiment finished in 2008 after more than 3 years of active operating time. Searches for both $0ν$ and $2ν$ double-beta decay to the first excited $0^{+}$ state in $^{130}$Xe were performed by studying different coincidence scenarios. The analysis was based on data representing a total exposure of N($^{130}$Te)$\cdot$t=$9.5\times10^{25}\,$y. No evidence for a signal was found. The resulting lower limits on the half lives are $T^{2ν}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>1.3\times10^{23}\,$y (90% C.L.), and $T^{0ν}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>9.4\times10^{23}\,$y (90% C.L.).

preprint2011arXiv

CUORE crystal validation runs: results on radioactive contamination and extrapolation to CUORE background

The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performances and the radiopurity of the TeO$_2$ crystals produced at SICCAS (Shanghai Institute of Ceramics, Chinese Academy of Sciences) for the CUORE experiment. In this work the results of the first 5 validation runs are presented. Results have been obtained for bulk contaminations and surface contaminations from several nuclides. An extrapolation to the CUORE background has been performed.

preprint2011arXiv

Search for beta plus/EC double beta decay of 120Te

We present a search for beta plus/EC double beta decay of 120Te performed with the CUORICINO experiment, an array of TeO2 cryogenic bolometers. After collecting 0.0573 kg y of 120Te, we see no evidence of a signal and therefore set the following limits on the half-life: T1/2 (0nu) > 1.9 10^{21} y at 90% C.L. for the 0 neutrino mode and T1/2 (2nu) > 7.6 10^{19} y at 90% C.L. for the two neutrino mode. These results improve the existing limits by almost three orders of magnitude (four in the case of 0 neutrino mode).

preprint2010arXiv

130Te Neutrinoless Double-Beta Decay with CUORICINO

We report the final result of the CUORICINO experiment. Operated between 2003 and 2008, with a total exposure of 19.75 kg y of 130Te, CUORICINO was able to set a lower bound on the 130Te 0nDBD half-life of 2.8 10^{24} years at 90% C.L. The limit here reported includes the effects of systematic uncertainties that are examined in detail in the paper. The corresponding upper bound on the neutrino Majorana mass is in the range 300--710 meV, depending on the adopted nuclear matrix element evaluation.

preprint2010arXiv

Broad Feshbach resonance in the 6Li-40K mixture

We study the widths of interspecies Feshbach resonances in a mixture of the fermionic quantum gases 6Li and 40K. We develop a model to calculate the width and position of all available Feshbach resonances for a system. Using the model we select the optimal resonance to study the 6Li/40K mixture. Experimentally, we obtain the asymmetric Fano lineshape of the interspecies elastic cross section by measuring the distillation rate of 6Li atoms from a potassium-rich 6Li/40K mixture as a function of magnetic field. This provides us with the first experimental determination of the width of a resonance in this mixture, Delta B=1.5(5) G. Our results offer good perspectives for the observation of universal crossover physics using this mass-imbalanced fermionic mixture.

preprint2010arXiv

Muon-induced backgrounds in the CUORICINO experiment

To better understand the contribution of cosmic ray muons to the CUORICINO background, 10 plastic scintillator detectors were installed at the CUORICINO site and operated during the final 3 months of the experiment. From these measurements, an upper limit of 0.0021 counts/(keV kg yr) (95% CL) was obtained on the cosmic ray-induced background in the neutrinoless double beta decay region of interest. The measurements were also compared to Geant4 simulations.

preprint2007arXiv

Calibration of a single atom detector for atomic micro chips

We experimentally investigate a scheme for detecting single atoms magnetically trapped on an atom chip. The detector is based on the photoionization of atoms and the subsequent detection of the generated ions. We describe the characterization of the ion detector with emphasis on its calibration via the correlation of ions with simultaneously generated electrons. A detection efficiency of 47.8% (+-2.6%) is measured, which is useful for single atom detection, and close to the limit allowing atom counting with sub-Poissonian uncertainty.

preprint2007arXiv

Phase coherent splitting of Bose-Einstein condensates with an integrated magnetic grating

We report the phase coherent splitting of Bose-Einstein condensates by means of a phase grating produced near the surface of a micro-electronic chip. A lattice potential with a period of $4μ$m is generated by the superposition of static and oscillating magnetic fields. Precise control of the diffraction is achieved by controlling the currents in the integrated conductors. The interference of overlapping diffraction orders is observed after 8ms of propagation in a harmonic trap and subsequent ballistic expansion of the atomic ensemble. By analyzing the interference pattern we show a reproducible phase relation between the diffraction orders with an uncertainty given by the resolution of the diffraction grating.

preprint2005arXiv

Diffraction of a Bose-Einstein condensate from a Magnetic Lattice on a Micro Chip

We experimentally study the diffraction of a Bose-Einstein condensate from a magnetic lattice, realized by a set of 372 parallel gold conductors which are micro fabricated on a silicon substrate. The conductors generate a periodic potential for the atoms with a lattice constant of 4 microns. After exposing the condensate to the lattice for several milliseconds we observe diffraction up to 5th order by standard time of flight imaging techniques. The experimental data can be quantitatively interpreted with a simple phase imprinting model. The demonstrated diffraction grating offers promising perspectives for the construction of an integrated atom interferometer.

preprint2004arXiv

Rubidium Spectroscopy at 778-780 nm with a Distributed Feedback Laser Diode

We have performed high resolution spectroscopy of rubidium with a single mode continuous wave distributed feedback (DFB) laser diode. The saturation spectrum of the D_2-line of 85Rb and 87Rb was recorded with a resolution close to the natural line width. The emission frequency was actively stabilized to Doppler-free transitions with a relative accuracy of better than 7 parts in 10^9 using commercially available servo devices only. An output power of 80 mW was sufficient to allow for two-photon spectroscopy of the 5S-5D-transition of 87Rb. Further, we report on the spectral properties of the DFB diode, its tuning range and its frequency modulation properties. The line width of the diode laser, determined with high resolution Doppler free two photon spectroscopy, was 4 MHz without applying any active stabilization techniques. For time scales below 5 us the line width drops below 2 MHz.