Source author record

S. K. Lamoreaux

S. K. Lamoreaux appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

29works
11topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

29 published item(s)

preprint2020arXiv

A quantum-enhanced search for dark matter axions

In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. We use vacuum squeezing to circumvent the quantum limit in a search for a new particle. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature, we double the search rate for axions over a mass range favored by recent theoretical projections. We observe no signature of dark matter axions in the combined $16.96-17.12$ and $17.14-17.28\spaceμ\text{eV}/c^2$ mass window for axion-photon couplings above $g_γ = 1.38\times g_γ^\text{KSVZ}$, reporting exclusion at the 90% level.

preprint2020arXiv

An improved analysis framework for axion dark matter searches

In experiments searching for axionic dark matter, the use of the standard threshold-based data analysis discards valuable information. We present a Bayesian analysis framework that builds on an existing processing protocol to extract more information from the data of coherent axion detectors such as operating haloscopes. The analysis avoids logical subtleties that accompany the standard analysis framework and enables greater experimental flexibility on future data runs. Performing this analysis on the existing data from the HAYSTAC experiment, we find improved constraints on the axion-photon coupling $g_γ$ while also identifying the most promising regions of parameter space within the $23.15$--$24.0$ $μ$eV mass range. A comparison with the standard threshold analysis suggests a $36\%$ improvement in scan rate from our analysis, demonstrating the utility of this framework for future axion haloscope analyses.

preprint2019arXiv

Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment

The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.

preprint2019arXiv

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.

preprint2015arXiv

New Experimental Limit on the Electric Dipole Moment of the Electron in a Paramagnetic Insulator

We report results of an experimental search for the intrinsic Electric Dipole Moment (EDM) of the electron using a solid-state technique. The experiment employs a paramagnetic, insulating gadolinium gallium garnet (GGG) that has a large magnetic response at low temperatures. The presence of the eEDM would lead to a small but non-zero magnetization as the GGG sample is subject to a strong electric field. We search for the resulting Stark-induced magnetization with a sensitive magnetometer. Recent progress on the suppression of several sources of background allows the experiment to run free of spurious signals at the level of the statistical uncertainties. We report our first limit on the eEDM of $(-5.57 \pm 7.98 \pm 0.12)\times$10$^{-25}$e$\cdot$cm with 5 days of data averaging.

preprint2014arXiv

Future Directions in the Microwave Cavity Search for Dark Matter Axions

The axion is a light pseudoscalar particle which suppresses CP-violating effects in strong interactions and also happens to be an excellent dark matter candidate. Axions constituting the dark matter halo of our galaxy may be detected by their resonant conversion to photons in a microwave cavity permeated by a magnetic field. The current generation of the microwave cavity experiment has demonstrated sensitivity to plausible axion models, and upgrades in progress should achieve the sensitivity required for a definitive search, at least for low mass axions. However, a comprehensive strategy for scanning the entire mass range, from 1-1000 $μ$eV, will require significant technological advances to maintain the needed sensitivity at higher frequencies. Such advances could include sub-quantum-limited amplifiers based on squeezed vacuum states, bolometers, and/or superconducting microwave cavities. The Axion Dark Matter eXperiment at High Frequencies (ADMX-HF) represents both a pathfinder for first data in the 20-100 $μ$eV range ($\sim$5-25 GHz), and an innovation test-bed for these concepts.

preprint2013arXiv

Analysis of single-photon and linear amplifier detectors for microwave cavity dark matter axion searches

We show that at higher frequencies, and thus higher axion masses, single-photon detectors become competitive and ultimately favored, when compared to quantum-limited linear amplifiers, as the detector technology in microwave cavity experimental searches for galactic halo dark matter axions. The cross-over point in this comparison is of order 10 GHz ($\sim 40\ μ$eV), not far above the frequencies of current searches.

preprint2013arXiv

Apparatus for Measurement of the Electric Dipole Moment of the Neutron using a Cohabiting Atomic-Mercury Magnetometer

A description is presented of apparatus used to carry out an experimental search for an electric dipole moment of the neutron, at the Institut Laue-Langevin (ILL), Grenoble. The experiment incorporated a cohabiting atomic-mercury magnetometer in order to reduce spurious signals from magnetic field fluctuations. The result has been published in an earlier letter; here, the methods and equipment used are discussed in detail.

preprint2012arXiv

A limit on the electron electric dipole moment using paramagnetic ferroelectric Eu$_{0.5}$Ba$_{0.5}$TiO$_3$

We report on the results of a search for the electron electric dipole moment $d_e$ using paramagnetic ferroelectric Eu$_{0.5}$Ba$_{0.5}$TiO$_3$. The electric polarization creates an effective electric field that makes it energetically favorable for the spins of the seven unpaired $4f$ electrons of the Eu$^{2+}$ to orient along the polarization, provided that $d_e\neq 0$. This interaction gives rise to sample magnetization, correlated with its electric polarization, and is therefore equivalent to a linear magnetoelectric effect. A SQUID magnetometer is used to search for the resulting magnetization. We obtain $d_e = (-1.07\pm3.06_\text{stat}\pm 1.74_\text{sys})\times10^{-25}\ecm$, implying an upper limit of $|d_e|<6.05\times10^{-25}\ecm$ (90% confidence).

preprint2012arXiv

Time dependent spin-dressing using a $^3$He atomic beam

We have performed high precision experimental measurements of spin precession using a dressed $^3$He atomic beam. Spin-dressing uses an oscillating magnetic field detuned to high frequency which is orthogonal to a static magnetic field to effectively change the gyromagnetic ratio of a spin. We verify the validity of the spin-dressing Hamiltonian in regions beyond the limiting solution in which the Larmor frequency is much smaller than the frequency of the dressing field. We also evaluate the effect of magnetic field misalignment, e.g. if the oscillating magnetic field is not orthogonal to the static magnetic field. Modulation of the dressing field parameters is also discussed, with a focus on whether such a modulation can be approximated merely as a time dependent, dressed gyromagnetic ratio. Furthermore, we discuss implications for a proposed search for the neutron electric dipole moment, which would employ spin-dressing to make the effective $^3$He and neutron magnetic moments equal.

preprint2011arXiv

New experimental limits on non-Newtonian forces in the micrometer-range

We report measurements of the short-range forces between two macroscopic gold-coated plates using a torsion pendulum. The force is measured for separations between 0.7 $μ$m and 7 $μ$m, and is well described by a combination of the Casimir force, including the finite-temperature correction, and an electrostatic force due to patch potentials on the plate surfaces. We use our data to place constraints on the Yukawa-type "new" forces predicted by theories with extra dimensions. We establish a new best bound for force ranges 0.4 $μ$m to 4 $μ$m, and, for forces mediated by gauge bosons propagating in $(4+n)$ dimensions and coupling to the baryon number, extract a $(4+n)$-dimensional Planck scale lower limit of $M_*>70$ TeV.

preprint2011arXiv

Offsets in Electrostatically Determined Distances: Implications for Casimir Force Measurements

The imperfect termination of static electric fields at semiconducting surfaces has been long known in solid state and transistor physics. We show that the imperfect shielding leads to an offset in the distance between two surfaces as determined by electrostatic force measurements. The effect exists even in the case of good conductors (metals) albeit much reduced.

preprint2011arXiv

On the Origin of the $\log d$ Variation of the Electrostatic Force Minimizing Voltage in Casimir Experiments

A number of experimental measurements of the Casimir force have observed a logarithmic distance variation of the voltage that minimizes electrostatic force between the plates in a sphere-plane geometry. We show that this variation can be simply understood from a geometric averaging of surface potential patches together with the Proximity Force Approximation.

preprint2010arXiv

First-principles design and subsequent synthesis of a material to search for the permanent electric dipole moment of the electron

We describe the first-principles design and subsequent synthesis of a new material with the specific functionalities required for a solid-state-based search for the permanent electric dipole moment of the electron. We show computationally that perovskite-structure europium barium titanate should exhibit the required large and pressure-dependent ferroelectric polarization, local magnetic moments, and absence of magnetic ordering even at liquid helium temperature. Subsequent synthesis and characterization of Eu$_{0.5}$Ba$_{0.5}$TiO$_3$ ceramics confirm the predicted desirable properties.

preprint2010arXiv

Observation of the thermal Casimir force

Quantum theory predicts the existence of the Casimir force between macroscopic bodies, due to the zero-point energy of electromagnetic field modes around them. This quantum fluctuation-induced force has been experimentally observed for metallic and semiconducting bodies, although the measurements to date have been unable to clearly settle the question of the correct low-frequency form of the dielectric constant dispersion (the Drude model or the plasma model) to be used for calculating the Casimir forces. At finite temperature a thermal Casimir force, due to thermal, rather than quantum, fluctuations of the electromagnetic field, has been theoretically predicted long ago. Here we report the experimental observation of the thermal Casimir force between two gold plates. We measured the attractive force between a flat and a spherical plate for separations between 0.7 $μ$m and 7 $μ$m. An electrostatic force caused by potential patches on the plates' surfaces is included in the analysis. The experimental results are in excellent agreement (reduced $χ^2$ of 1.04) with the Casimir force calculated using the Drude model, including the T=300 K thermal force, which dominates over the quantum fluctuation-induced force at separations greater than 3 $μ$m. The plasma model result is excluded in the measured separation range.

preprint2010arXiv

Quantum dense coding without entanglement

We describe a quantum cryptography protocol with up to twenty four-dimensional ($\mathcal{D} =4$) states generated by a polarization-, phase- and time-encoding transmitter. This protocol can be experimentally realized with existing technology, drawing from time-encoded and polarization-encoded systems. The protocol is error tolerant and has a quantum bit-rate of 2 per transmission/detection, which when combined with state detection efficiency yields a qubit efficiency of up to 1 or double that of BB84-{\it like} protocols.

preprint2010arXiv

Surface Contact Potential Patches and Casimir Force Measurements

We present calculations of contact potential surface patch effects that simplify previous treatments. It is shown that, because of the linearity of Laplace's equation, the presence of patch potentials does not affect an electrostatic calibration (of force and/or distance) of a two-plate Casimir measurement apparatus. Using models that include long-range variations in the contact potential across the plate surfaces, a number of experimental observations can be reproduced and explained. For these models, numerical calculations show that if a voltage is applied between the plates which minimizes the force, a residual electrostatic force persists, and that the minimizing potential varies with distance. The residual force can be described by a fit to a simple two-parameter function involving the minimizing potential and its variation with distance. We show the origin of this residual force by use of a simple parallel capacitor model. Finally, the implications of a residual force that varies in a manner different from 1/d on the accuracy of previous Casimir measurements is discussed.

preprint2010arXiv

Systematic Correction for "Demonstration of the Casimir Force in the 0.6 to 6 micrometer Range"

A new systematic correction for Casimir force measurements is proposed and applied to the results of an experiment that was performed more than a decade ago. This correction brings the experimental results into good agreement with the Drude model of the metallic plates' permittivity. The systematic is due to time-dependent fluctuations in the distance between the plates caused by mechanical vibrations or tilt, or position measurement uncertainty, and is similar to the correction for plate roughness.

preprint2009arXiv

Comment on "Rovibrational quantum interferometers and gravitational waves"

In a recent paper, Wicht, Lämmerzahl, Lorek, and Dittus [Phys. Rev. {\bf A 78}, 013610 (2008)] come to the conclusion that a molecular rotational-vibrational quantum interferometer may possess the sensitivity necessary to detect gravitational waves. We do not agree with their results and demonstrate here that the true sensitivity of such interferometer is many orders of magnitude worse than that claimed in the mentioned paper. In the present comment we estimate the expected energy shifts and derive equations of motion for a quantum symmetric top (diatomic molecule or deformed nucleus) in the field of gravitational wave, and then estimate the sensitivity of possible experiments.

preprint2009arXiv

Measurement of the short-range attractive force between Ge plates using a torsion balance

We have measured the short-range attractive force between crystalline Ge plates, and found contributions from both the Casimir force and an electrical force possibly generated by surface patch potentials. Using a model of surface patch effects that generates an additional force due to a distance dependence of the apparent contact potential, the electrical force was parameterized using data at distances where the Casimir force is relatively small. Extrapolating this model, to provide a correction to the measured force at distances less than 5 $μ$m, shows a residual force that is in agreement, within experimental uncertainty, with five models that have been used to calculate the Casimir force.

preprint2009arXiv

Measuring the Neutron Lifetime Using Magnetically Trapped Neutrons

The neutron beta-decay lifetime plays an important role both in understanding weak interactions within the framework of the Standard Model and in theoretical predictions of the primordial abundance of 4He in Big Bang Nucleosynthesis. In previous work, we successfully demonstrated the trapping of ultracold neutrons (UCN) in a conservative potential magnetic trap. A major upgrade of the apparatus is nearing completion at the National Institute of Standards and Technology Center for Neutron Research (NCNR). In our approach, a beam of 0.89 nm neutrons is incident on a superfluid 4He target within the minimum field region of an Ioffe-type magnetic trap. A fraction of the neutrons is downscattered in the helium to energies <200 neV, and those in the appropriate spin state become trapped. The inverse process is suppressed by the low phonon density of helium at temperatures less than 200 mK, allowing the neutron to travel undisturbed. When the neutron decays the energetic electron ionizes the helium, producing scintillation light that is detected using photomultiplier tubes. Statistical limitations of the previous apparatus will be alleviated by significant increases in field strength and trap volume resulting in twenty times more trapped neutrons.

preprint2009arXiv

The prospects for an electron electric dipole moment search with ferroelectric (Eu,Ba)TiO$_3$ ceramics

We propose to use ferroelectric (Eu,Ba)TiO$_3$ ceramics just above their magnetic ordering temperature for a sensitive electron electric dipole moment search. We have synthesized a number of such ceramics with various Eu concentrations and measured their properties relevant for such a search: permeability, magnetization noise, and ferroelectric hysteresis loops. The results of our measurements indicate that a search for the electron electric dipole moment with Eu$_{0.5}$Ba$_{0.5}$TiO$_3$ should lead to an order of magnitude improvement on the current best limit.

preprint2007arXiv

Investigation of the Gravitational Potential Dependence of the Fine-Structure Constant Using Atomic Dysprosium

Radio-frequency E1 transitions between nearly degenerate, opposite parity levels of atomic dysprosium were monitored over an eight month period to search for a variation in the fine-structure constant. During this time period, data were taken at different points in the gravitational potential of the Sun. The data are fitted to the variation in the gravitational potential yielding a value of $(-8.7 \pm 6.6) \times 10^{-6}$ for the fit parameter $k_α$. This value gives the current best laboratory limit. In addition, our value of $k_α$ combined with other experimental constraints is used to extract the first limits on k_e and k_q. These coefficients characterize the variation of m_e/m_p and m_q/m_p in a changing gravitational potential, where m_e, m_p, and m_q are electron, proton, and quark masses. The results are $k_e = (4.9 \pm 3.9) \times 10^{-5}$ and $k_q = (6.6 \pm 5.2) \times 10^{-5}$.

preprint2006arXiv

Linear electric field frequency shift (important for next generation electric dipole moment searches) induced in confined gases by a magnetic field gradient

The search for particle electric dipole moments (edm) represents a most promising way to search for physics beyond the standard model. A number of groups are planning a new generation of experiments using stored gases of various kinds. In order to achieve the target sensitivities it will be necessary to deal with the systematic error resulting from the interaction of the well-known $\overrightarrow{v}\times \overrightarrow{E}$ field with magnetic field gradients (often referred to as the geometric phase effect (Commins, ED; Am. J. Phys. \QTR{bf}{59}, 1077 (1991), Pendlebury, JM \QTR{em}{et al;} Phys. Rev. \QTR{bf}{A70}, 032102 (2004)). This interaction produces a frequency shift linear in the electric field, mimicking an edm. In this work we introduce an analytic form for the velocity auto-correlation function which determines the velocity-position correlation function which in turn determines the behavior of the frequency shift (Lamoreaux, SK and Golub, R; Phys. Rev \QTR{bf}{A71}, 032104 (2005)) and show how it depends on the operating conditions of the experiment. We also discuss some additional issues.

preprint2005arXiv

Collisional perturbation of radio-frequency E1 transitions in an atomic beam of dysprosium

We have studied collisional perturbations of radio-frequency (rf) electric-dipole (E1) transitions between the nearly degenerate opposite-parity levels in atomic dysprosium (Dy) in the presence of 10 to 80 $μ$Torr of H$_\text{2}$, N$_\text{2}$, He, Ar, Ne, Kr, and Xe. Collisional broadening and shift of the resonance, as well as the attenuation of the signal amplitude are observed to be proportional to the foreign-gas density with the exception of H$_2$ and Ne, for which no shifts were observed. Corresponding rates and cross sections are presented. In addition, rates and cross sections for O$_2$ are extracted from measurements using air as foreign gas. The primary motivation for this study is the need for accurate determination of the shift rates, which are needed in a laboratory search for the temporal variation of the fine-structure constant [A. T. Nguyen, D. Budker, S. K. Lamoreaux, and J. R. Torgerson, Phys. Rev. A \textbf{69}, 22105 (2004)].

preprint2005arXiv

Measurement of the electron electric dipole moment using GdIG

A new method for the detection of the electron edm using a solid is described. The method involves the measurement of a voltage induced across the solid by the alignment of the samples magnetic dipoles in an applied magnetic field, H. A first application of the method to GdIG has resulted in a limit on the electron edm of 5E-24 e-cm, which is a factor of 40 below the limit obtained from the only previous solid-state edm experiment. The result is limited by the imperfect discrimination of an unexpectedly large voltage that is even upon the reversal of the sample magnetization.

preprint2003arXiv

An Apparatus to Control and Monitor the Para-D2 Concentration in a Solid Deuterium, Superthermal Source of Ultra-cold Neutrons

Controlling and measuring the concentration of para-D2 is an essential step toward realizing solid deuterium as an intense ultra-cold neutron (UCN) source. To this end, we implemented an experimental technique to convert para- to ortho-deuterium molecules by flowing D2 gas through a cryogenic cell filled with paramagnetic hydrous ferric oxide granules. This process efficiently reduced the para-D2 concentration from 33.3% to 1.5%. Rotational Raman spectroscopy was applied to measure the residual para-D2 contamination to better than 2 parts in 10^3, and the hydrogen contamination to 1 part in 10^3. We also contrast our optical technique to conventional thermal conductivity measurements of the para-D2 concentration, reporting some of the relevant strengths and weaknesses of our implementation of each technique.

preprint2002arXiv

Calculation of the ultracold neutron upscattering loss probability in fluid walled storage bottles using experimental measurements of the thermomechanical properties of Fomblin

We present experimental measurements of the properties of a liquid "Fomblin" surface obtained by the quasielastic scattering of laser light. The properties include the surface tension and viscosity as a function of temperature. The results are compared to the measurements of the bulk fluid properties. We then calculate the upscattering rate of ultracold neutrons (UCN) from thermally excited surface capillary waves on the liquid surface and compare the results to experimental measurements of the UCN lifetime in Fomblin fluid-walled UCN storage bottles, and show that the excess loss rate for UCN energies near the Fomblin potential can be explained. The rapid temperature dependence of the Fomblin storage lifetime is explained by our analysis.