Researcher profile

S. E. Müller

S. E. Müller contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Mini-Proceedings of the STRONG2020 Virtual Workshop on "Space-like and Time-like determination of the Hadronic Leading Order contribution to the Muon $g-2$"

The mini-proceedings of the STRONG2020 Virtual Workshop "Space-like and Time-like determination of the Hadronic Leading Order contribution to the Muon $g-2$", November 24--26 2021, are presented. This is the first workshop of the STRONG2020 WP21: JRA3-PrecisionSM: Precision Tests of the Standard Model (http://www.strong-2020.eu/joint-research-activity/jra3-precisionsm.html). The workshop was devoted to review of the working group activitity on: $(\it i)$ Radiative Corrections and Monte Carlo tools for low-energy hadronic cross sections in $e^+ e^-$ collisions; $(\it ii)$ Annotated database for $e^+e^-$ into hadrons processes at low energy; $(\it iii)$ Radiative Corrections and Monte Carlo tools for $μ$-$e$ elastic scattering.

preprint2022arXiv

Mu2e-II: Muon to electron conversion with PIP-II

An observation of Charged Lepton Flavor Violation (CLFV) would be unambiguous evidence for physics beyond the Standard Model. The Mu2e and COMET experiments, under construction, are designed to push the sensitivity to CLFV in the mu to e conversion process to unprecedented levels. Whether conversion is observed or not, there is a strong case to be made for further improving sensitivity, or for examining the process on additional target materials. Mu2e-II is a proposed upgrade to Mu2e, with at least an additional order of magnitude in sensitivity to the conversion rate over Mu2e. The approach and challenges for this proposal are summarized. Mu2e-II may be regarded as the next logical step in a continued high-intensity muon program at FNAL.

preprint2021arXiv

Photoexcitation of $^{76}$Ge

The dipole strength of the nuclide $^{76}$Ge was studied in photon-scattering experiments using bremsstrahlung produced with electron beams of energies of 7.8 and 12.3 MeV at the $γ$ELBE facility. We identified 210 levels up to an excitation energy of 9.4 MeV and assigned spin $J$ = 1 to most of them. The quasicontinuum of unresolved transitions was included in the analysis of the spectra and the intensities of branching transitions were estimated on the basis of simulations of statistical $γ$-ray cascades. The photoabsorption cross section up to the neutron-separation energy was determined and is compared with predictions of the statistical reaction model. The derived photon strength function is compared with results of experiments using other reactions.

preprint2020arXiv

Neutron flux and spectrum in the Dresden Felsenkeller underground facility studied by moderated $^3$He counters

Ambient neutrons may cause significant background for underground experiments. Therefore, it is necessary to investigate their flux and energy spectrum in order to devise a proper shielding. Here, two sets of altogether ten moderated $^3$He neutron counters are used for a detailed study of the ambient neutron background in tunnel IV of the Felsenkeller facility, underground below 45 meters of rock in Dresden/Germany. One of the moderators is lined with lead and thus sensitive to neutrons of energies higher than 10 MeV. For each $^3$He counter-moderator assembly, the energy dependent neutron sensitivity was calculated with the FLUKA code. The count rates of the ten detectors were then fitted with the MAXED and GRAVEL packages. As a result, both the neutron energy spectrum from 10$^{-9}$ MeV to 300 MeV and the flux integrated over the same energy range were determined experimentally. The data show that at a given depth, both the flux and the spectrum vary significantly depending on local conditions. Energy integrated fluxes of $(0.61 \pm 0.05)$, $(1.96 \pm 0.15)$, and $(4.6 \pm 0.4) \times 10^{-4}$ cm$^{-2}$ s$^{-1}$, respectively, are measured for three sites within Felsenkeller tunnel IV which have similar muon flux but different shielding wall configurations. The integrated neutron flux data and the obtained spectra for the three sites are matched reasonably well by FLUKA Monte Carlo calculations that are based on the known muon flux and composition of the measurement room walls.

preprint2020arXiv

Source term calculation and validation for ${}^{18}$F-production with a cyclotron for medical applications at HZDR

In this document we present the calculation and experimental validation of a source term for ${}^{18}$F-production with a cyclotron for medical applications operating at 18 MeV proton energy and 30 $μ$A proton current. The Monte Carlo codes MCNP6 and FLUKA were used for the calculation of the source term. In addition, the radiation field around the $^{18}$O-enriched water target was simulated with the two codes. To validate the radiation field obtained in the simulation, an experimental program has been started using activation samples which are placed close to the water target during an ${}^{18}$F-production run of the cyclotron. After the irradiation, the samples are analyzed and the resulting activation is compared to Monte Carlo calculations of the expected sample activation. We find good agreement between simulations and experimental results, with most calculation to experiment (C/E) ratios well between 0.6 and 1.4.