Researcher profile

S. Corrodi

S. Corrodi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Development of the Scintillating Fiber Timing Detector for the Mu3e Experiment

We present and discuss the development and performance of a compact scintillating fiber (SciFi) detector for timing to be used in the Mu3e experiment at very high particle rates. The SciFi detector is read out with multichannel silicon photomuiltipliers (SiPM) arrays at both ends to achieve the best timing performance. Mu3e is a new experiment under preparation at the Paul Scherrer Institute to search for charged Lepton Flavor Violation in the rare neutrinoless muon decay mu->eee using the most intense continuous surface muon beam in the world. The Mu3e detector is based on thin high-voltage monolithic active silicon pixel sensors (HV-MAPS) for very precise tracking in conjunction with scintillating fibers and scintillating tiles coupled to SiPMs for accurate timing measurements and it is designed to operate at very high intensities. In order to reach a single event sensitivity of 10^-16 for this rare mu->eee muon decay, all backgrounds must be rejected well below this level. To suppress all forms of accidental background, a very thin SciFi detector (thickness < 0.2% of a radiation length X_0) with a time resolution of 250 ps, efficiency in excess of 96%, and spatial resolution of 100 micron has been developed. In this paper we report on the development, construction, and performance of this SciFi detector. Different scintillating fiber types have been evaluated and various assembly procedures have been tested to achieve the best performance. The compact size, fast response, good timing, high spatial resolution, insensitivity to magnetic fields, and adaptable geometry make SciFi detectors suitable for a variety of applications.

preprint2022arXiv

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab

The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω&#39;^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω&#39;^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω&#39;^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.

preprint2022arXiv

Mu2e-II: Muon to electron conversion with PIP-II

An observation of Charged Lepton Flavor Violation (CLFV) would be unambiguous evidence for physics beyond the Standard Model. The Mu2e and COMET experiments, under construction, are designed to push the sensitivity to CLFV in the mu to e conversion process to unprecedented levels. Whether conversion is observed or not, there is a strong case to be made for further improving sensitivity, or for examining the process on additional target materials. Mu2e-II is a proposed upgrade to Mu2e, with at least an additional order of magnitude in sensitivity to the conversion rate over Mu2e. The approach and challenges for this proposal are summarized. Mu2e-II may be regarded as the next logical step in a continued high-intensity muon program at FNAL.

preprint2022arXiv

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/μ}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/μ}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$π$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

preprint2022arXiv

Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment

The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than the current experimental result, reaching the precision of the Standard Model (SM) prediction at 1 part in $10^4$. Considering several inconsistencies between the SM predictions and data pointing towards the potential violation of lepton flavor universality, the PIONEER experiment will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles up to the PeV mass scale. The later phases of the PIONEER experiment aim at improving the experimental precision of the branching ratio of pion beta decay (BRPB), $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three (Phase II) and an order of magnitude (Phase III). Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of $|V_{ud}|$ at the 0.02\% level, comparable to the deduction from superallowed beta decays.

preprint2021arXiv

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The E989 Muon $g-2$ experiment at Fermilab aims to measure the anomalous magnetic moment, $a^{}_μ$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $ω^{}_a$, and the average magnetic field in terms of the shielded proton Larmor frequency, $ω&#39;^{}_p$. The measurement of $ω&#39;^{}_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration. A crucial element for the multi-step measurement of $ω&#39;^{}_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.